velbus VMB4RYLD Programmable 4 Channel Voltage Out Relay Module User Manual
- June 12, 2024
- VELBUS
Table of Contents
VMB4RYLD Programmable 4 Channel Voltage Out Relay Module
User Manual
VMB4RYLD
Programmable
4-channel voltage out relay module for Velbus system
VMB4RYLD Programmable 4 Channel Voltage Out Relay Module
DESCRIPTION
This relay module is suited for switching on or off the lighting in the living
room, the garden fountain, the mains outlets in the children’s room, and many
more.
In order to limit the wiring in the switchboard cabinet, this module features
a mains voltage input and four voltage outputs to which the consumer can be
connected directly.
This is only suited for use in a Velbus system.
Multiple functions, e.g. switching on/off timers, are to be programmed via the
Velbuslink software.
CHARACTERISTICS
Use:
- suitable for switching on/off mains-powered lighting or consumers
- connection of a low voltage (e.g. 12V) instead of a high mains voltage to the voltage input allows the switching of up to 4 low-voltage consumers (e.g. 12V light bulbs)
- only suitable for use in a Velbus installation
Outputs:
- 4 voltage outputs with common N connection
- single-pole NO relay contact
- relay contact debounce
- switching capacity:
- 16A @ 230VAC input voltage
- 12A @ 30VDC input voltage
- allowed switch-on current up to 80A (lamp switch-on current)
- Total allowed consumption of the 4 channels:
- 16A @ 230VAC
- 12A @ 30VDC
- each relay channel may be inverted in order to simulate an NC contact
- 1 extra virtual channel
LED indications:
- status indication for all 4 channels
- continuously lit: relay switched on
- slow blinking: timer 1 running
- fast blinking: timer 2 running
- two short blinks: communication error
- power voltage present
- data reception and transfer over the Velbus
- status notification of the relay channels to the control modules
Module power supply:
- required power voltage: 12…18VDC
- consumption in stand-by: 30mA
- max. consumption: 250mA
Dimensions:
- standard DIN-rail housing: 4 modules
- L x W x H: 90 x 71 x 58mm
Configuration:
- only configurable via the Velbus PC interface (VMB1USB, VMB1RS or VMBRSUSB) and the Velbuslink software
- addressing through software (up to 250 addresses)
- storage space for 39 different pushbuttons and their function
- multiple functions and timer settings are configurable through software
- learned pushbuttons are saved in case of a power failure
Control:
- local on/off control on the module
- no direct pushbutton connections
- through Velbus commands or pushbuttons connected to the Velbus system
- multiple control functions
- moment
- off
- on
- on/off
- timer (start/stop, restartable or non-restartable, switch-on/off delay, interval)
- output forced off
- output forced on
- output inhibition
- etc.
Timer presets:
- only configurable through the Velbuslink software
- timer presets configurable between:
- 1 sec and 2 min in steps of 1 sec
- 2 min and 5 min in steps of 15 sec
- 5 min and 30 min in steps of 30 sec
- 30 min and 1 hour in steps of 1 min
- 1 hour and 5 hours in steps of 15 min
- 5 hours and 10 hours in steps of 30 min
- 10 hours and 24 hours in steps of 1 hour
- 2 days
- 3 days
- no switch-off timer
VELBUS CHARACTERISTICS
- 2-wire communication for Velbus data and 2 wires for power
- data transfer: 16.6 kbit/s
- serial data protocol: CAN (Controller Area Network)
- short-circuit proof (towards (-) or (+) of power)
- bus error indication: 2 short blinks of the operation mode LED
- self-restoring after 25 seconds in case of a bus error
Possibility to assign a name (max. 16 characters) to each output channel.
The relay module can send following messages:
- relay status
- relay module type (with software version)
- channel names
- communication error counter
- memory capacity
The relay module can send following commands:
- switch off LEDs on a control module
- switch on LEDs on a control module
- slow or fast blinking of the LEDs on a control module
The relay module can receive following messages:
- pushbutton module status
The relay module can receive following commands:
- switch on relay channel
- switch off relay channel
- start timer
- start blinking timer
- recall relay status
- recall module type and software version
- recall communication error counter
- recall relay names
- recall memory contents
- overwrite memory contents
- switch off pushbutton indication LED
OVERVIEW
Connections
-
consumer output channel 1
-
consumer output channel 2
-
consumer output channel 3
-
consumer output channel 4
-
consumer output voltage
-
Velbus
-
Velbus power supply
LED indications -
power LED
-
Velbus RX (receive) LED
-
Velbus TX (transmit) LED
-
output status
LED INDICATIONS
LOCAL CONTROL
Remove the cover.
USE
Connecting a 230V mains voltage to the input allows you to switch 4 mains
voltage consumers like lighting, a pump, an electric heater, electric valves,
etc.
Connecting a 12V low voltage to the input allows you to switch 4 low-voltage
consumers like low-voltage lighting, LED strips, low-voltage LED spots, etc.
The module is integrated into the Velbus system and controlled through the
VMB4PD control panel or by means of pushbuttons connected to a VMB8PB
pushbutton interface, VMB6IN or any other relay module.
To interconnect the Velbus modules it is recommended to use a twisted-pair
cable (EIB 2x2x0.8mm², UTP 4x2x0.51mm² – CAT5 or equivalent).
Make sure to use a heavy-gauge wire (0.5mm2 or more) in case of a multiple
module connection (>10 modules) or with log connections (>50m).
Connect the bus to the module (mind the polarity).
Mains Voltage Connection Diagram
A single-pole load (e.g. lighting) can be connected directly to the output.
Maximum total current consumption: 16A
A double-pole load (e.g. mains outlet) requires an extra double-pole relay.
A triple-pole load (e.g. water heater) requires a quadrupole relay.
Low-Voltage Connection Diagram
The module is also suitable for controlling 12V or 24V LED bulbs or strips.
The input will then be connected to a low-voltage power supply (12V or 24V).
Choose a power supply which can deliver the required consumption while the
total consumption does not exceed 12A.
Termination
Remove the cover.
Generally, only 2 ‘TERM’ terminators must be used in a complete Velbus®
installation. Usually, this will be on one module inside the distribution box
and on the module which is physically located furthest from the distribution
box. On all other modules, the terminator must be removed. Remark:
In case of a wiring with multiple branches, only place a termination into a
single module in the distribution box and in the control panel which is the
farthest from the distribution box. When communication problems occur, you can
place an extra termination on another branch. It is highly recommended to
limit the number of terminations as too large a number may overload the bus.
Configuration
This relay module can only be configured through the Velbuslink software.
The address, behaviour and control functions can be configured manually.
Address
Each module in the Velbus connection must have a unique address.
Configure the address through the software.
Relay Contact Behaviour
The relay contact will behave as an NO contact (no voltage on the outputs at
no load).
With the software, this behaviour can be modified to an NO contact: at no load
(when the indication LED does not light) the relay contact will be closed and
the output will present a voltage. Make sure however this occurs when the
relay module is live.
Control Functions
The relay module is controlled through pushbuttons connected to the Velbus
system via a pushbutton interface or control panel.
You may assign up to 39 different pushbuttons. Each pushbutton may activate a
different function.
| Function| Description
---|---|---
1| Momentary| The relay remains switched on as long as the pushbutton is
pressed.
2| Off| The relay is switched off.
In order to create an “all off” function, the same pushbutton of all relay
channels will be configured as an off function.
3| Off with timers disabled| The relay is switched off and the timers cannot
be restarted.
4| Off with timers disabled at short press| A short press of the pushbutton
switches off the relay but the timers cannot be restarted.
A long press of the pushbutton switches off the relay and the timers remain
enabled.
5| Off with timers disabled at long press| A short press of the pushbutton
switches off the relay and the timers remain enabled.
A long press of the pushbutton switches off the relay but the timers cannot be
restarted.
6| On| The relay is switched on.
May be used in a control panel with weekly program to switch on an output at a
certain point in time.
7| On with timers disabled| The relay is switched on and the timers cannot be
restarted.
When a PIR detector is triggered, the driveway lighting will switch on for 10
minutes.
A pushbutton with the “On with timers disabled” function allows to switch on
the driveway lighting continuously without the PIR detector having an
influence on the action.
8| On with timers disabled at short press| A short press of the pushbutton
switches on the relay but the timers cannot be restarted.
A long press of the pushbutton switches on the relay and the timers remain
enabled.
9| On with timers disabled at long press| A short press of the pushbutton
switches on the relay and the timers remain enabled.
A long press of the pushbutton switches on the relay but the timers cannot be
restarted.
10| Toggle| Each press toggles the relay status (on/off).
Normal lighting control in a room.
11| Toggle with timers disabled| Each press toggles the relay status (on/off).
The timers cannot be started when the relay is switched on.
A PIR detector will switch on the driveway lighting; this lighting can
switched on/off with a pushbutton. A driveway lighting switched on through the
pushbutton will not be affected by the PIR detector.
12| Toggle with timers disabled at short press| Each press toggles the relay
status (on/off).
The timers cannot be started when the relay was switched on by a short press.
13| Toggle with timers disabled at long press| Each press toggles the relay
status (on/off).
The timers cannot be started when the relay was switched on by a long press.
14| Start/stop timer| A press of the pushbutton switches on the relay for a
preset time.
A press of the pushbutton switches off the switched-on relay immediately.
If desired, the short and long press delays can be set.
Control of the lighting in the attic. The lighting will automatically switch
off after a preset time.
15| Restartable timer| A press of the pushbutton switches on the relay for a
preset time.
A press of the pushbutton while the relay is switched on restarts the timer.
If desired, the short and long press delays can be set.
This function is also called a staircase lighting timer.
16| Non retriggerable timer| A press of the pushbutton switches on the relay
for a preset time.
A press of the pushbutton while the relay is switched on has no effect.
17| Trigger-on-release timer| The relay status remains unchanged with the
closing of the switch.
The relay is switched on for a preset time with the opening of the switch.
18| Delayed off at release| The relay is switched off with the closing of the
switch.
The relay remains switched on for a preset time with the opening of the
switch.
19| Delayed off at release only when relay is on| Nothing happens as long as
the relay remains switched off. At the release of the pushbutton, the
switched-on relay will remain switched on for a preset time.
20| Start/stop with delayed on/off| Pressing the pushbutton will switch on the
relay after the expiration of the switch-on delay. The relay is switched off
again
after expiration of the switch-off delay.
Pressing the pushbutton while the switch-on or switch-off delay is running
will annul the timer and switch off the relay.
21| Restartable delayed on/off| Pressing the pushbutton will switch on the
relay after the expiration of the switch-on delay. The relay is switched off
again
after expiration of the switch-off delay.
Pressing the pushbutton while the switch-on delay is running will restart the
switch-on delay.
22| Non restartable delayed on/off| Pressing the pushbutton will switch on the
relay after the expiration of the switch-on delay. The relay is switched off
again
after expiration of the switch-off delay.
Pressing the pushbutton while the switch-on or switch-off delay is running
does not affect the general status.
23| Start/stop interval timer| Pressing the pushbutton will switch on the
interval timer for a preset time. The output is thus repeatedly open and
closed. The switch-on and switch-off delays can be set.
Pressing the pushbutton while the interval timer is running will stop the
interval timer.
24| Restartable interval timer| Pressing the pushbutton will switch on the
interval timer for a preset time. The output is thus repeatedly open and
closed. The switch-on and switch-off delays can be set.
Pressing the pushbutton while the interval timer is running will restart the
interval timer.
25| Non restartable interval timer| Pressing the pushbutton will switch on the
interval timer for a preset time. The output is thus repeatedly open and
closed. The switch-on and switch-off delays can be set.
26| Forced off at closed switch| The relay cannot be switched on as long as
the switch is closed.
A light sensor will keep the driveway lighting switched off during daylight.
27| Forced off at opened switch| The relay cannot be switched on as long as
the switch is open.
28| Forced off at pushbutton press| Pressing the pushbutton will disable the
switching-on of the relay for a preset time.
The use of a control panel with weekly program allows you to disable the
output control of an output for a preset time.
29| Toggle forced off at pushbutton press| Pressing the pushbutton will
disable the switching-on of the relay for a preset time.
Repressing that same pushbutton will cancel the forced-off mode.
30| Cancel forced off at pushbutton press| Pressing the pushbutton will cancel
the forced-off mode.
Remark:
The forced-off status can still be determined by the function forced off at
opened or closed switch.
31| Forced on at closed switch| The relay is switched on as long as the switch
is closed. All other commands are ignored.
Remark:
The forced-off function overrules the forced-on function.
32| Forced on at open switch| The relay is switched on as long as the switch
is open. All other commands are ignored.
Remark:
The forced-off function overrules the forced-on function.
33| Forced on at pushbutton press| Pressing the pushbutton will switch on the
relay. All other commands are ignored for a preset time.
Remark:
The forced-off function overrules the forced-on function.
34| Toggle forced-on at pushbutton press| Pressing the pushbutton will switch
on the relay. All other commands are ignored for a preset time. Repressing
that same
pushbutton will cancel the forced-on mode.
Remark:
The forced-off function overrules the forced-on function.
35| Cancel forced-on at pushbutton press| Pressing the pushbutton will cancel
the forced-on mode.
Remark:
The forced-on status can still be determined by the function forced off at
opened or closed switch.
36| Inhibit at closed switch| The relay is switched off as long as the switch
is closed. The functions will still be active internally. The internal status
will be transferred to the relay at the opening of the switch.
37| Inhibit at open switch| The relay is switched off as long as the switch is
open. The functions will still be active internally. The internal status will
be transferred to the relay at the closing of the switch.
38| Inhibit at pushbutton press| Pressing the pushbutton will switch off the
relay for a preset time.
The functions will still be active internally.
39| Toggle inhibit at pushbutton press| Pressing the pushbutton will switch
off the relay for a preset time.
The functions will still be active internally. Repressing that same pushbutton
will cancel the inhibition mode.
40| Cancel inhibit at pushbutton press| Pressing the pushbutton will transfer
the internal status to the relay.
A light sensor will switch on the garden lighting at dusk. A pushbutton on the
control panel will inhibit the output at 23h00; a second pushbutton will
cancel this inhibition at 06h00 via the weekly program. This will keep the
garden lighting switched off between 23h00 and 06h00.
Some functions allow you to set the switch-off time, the switch-on delay or the pulse and pause time between:
- 1 sec and 2 min in steps of 1 sec
- 2 min and 5 min in steps of 15 sec
- 5 min and 30 min in steps of 30 sec
- 30 min and 1 hour in steps of 1 min
- 1 hour and 5 hours in steps of 15 min
- 5 hours and 10 hours in steps of 30 min
- 10 hours and 24 hours in steps of 1 hour
- 2 days
- 3 days
- no switch-off timer
CHECKING THE SOFTWARE VERSION
The software version can be verified via the Velbus link software.
Check on http://www.velbus.eu whether you have the latest version. If a
newer version is available, download it.
Connect the Velbus interface to a PC and run the upgrade-software and follow
the instructions on the screen.
Remark:
Upgrading a module is not without risk. Do not interrupt the process!
If for any reason the upgrade should fail, the module will cease normal
operation. The module will have to be returned to the manufacturer.
Refer to our website for more information: www.velbus.be
VMB4RYLD 4-channel relay module
version 1
Documents / Resources
|
velbus VMB4RYLD Programmable 4 Channel Voltage Out Relay
Module
[pdf] User Manual
VMB4RYLD_gb_rev1, VMB4RYLD Programmable 4 Channel Voltage Out Relay Module,
VMB4RYLD, VMB4RYLD 4 Channel Voltage Out Relay Module, Programmable 4 Channel
Voltage Out Relay Module, 4 Channel Voltage Out Relay Module, 4 Channel Relay
Module, Voltage Out Relay Module, Relay Module, Relay, Module
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>