KONIG MEYER 26720-022-55 Monitor Stand Instruction Manual
- June 12, 2024
- KONIG MEYER
Table of Contents
- KONIG MEYER 26720-022-55 Monitor Stand
- Product Information
- Product Usage Instructions
- INTENDED USE
- FEATURES & CAPABILITIES
- SAFETY INSTRUCTIONS
- SET-UP INSTRUCTIONS
- SUPPORT for the MONITOR
- USER INSTRUCTIONS / FUNCTIONS
- EXTENDING
- RETRACTION
- CABLE ROUTING
- DIMENSIONS
- CHECK, MAINTENANCE, CLEANING
- TECHNICAL DATA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KONIG MEYER 26720-022-55 Monitor Stand
Product Information
Product Name: 26720/26722 Monitor Stand
Components: Base tubes, tube combination, bearing plate, screws, clamping
screw, safety hook, leg tubes, discs, carriage bolts, lock nut, cover cap
Material: Stahl (Steel), schwarz gepulvert (black powder coated)
Maximum Load Capacity: 35 kg
Dimensions: 702 x 321 x 138 mm
Product Usage Instructions
- Safety Instructions:
- The stand should be visually inspected before and after use.
- Do not use damaged or incomplete stands unless they have been repaired.
- Ensure that the floor is level and stable.
- Exercise caution during installation and handling to prevent injuries.
- Wear protective gloves.
- Keep unauthorized persons away from the stand.
- Follow the instruction manual and keep it for future reference.
- Assembly:
- Handle base tubes, tube combination, and bearing plate with care and do not drop them.
- Ensure that the screw connections are tight (base, tubes, bearing plate).
- Extending/Retracting the Load:
- Before extending/retracting, remove the monitor from the bearing plate.
- If the monitor is directly screwed, follow the specified procedure with two competent persons (P1, P2).
- P1: Hold the extension tube together with the load firmly and securely.
- P2: Secure the selected height by engaging the safety hook and tightening the clamping screw.
- Disassembly:
- Always lift the load from the stand first before retracting or dismantling.
- Handle and store components with care.
- Set-Up Instructions:
- Use the enclosed rubber knobs to minimize vibrations between the monitor, stand, and floor.
- Remove the protective film from the rubber knobs and stick them to the desired place on the plate.
- Assembly Stand:
- Place the leg tubes between the two discs of the base tube.
- Connect the leg tubes by inserting carriage bolts from below and screwing them with lock nuts using a wrench.
- Push the cover cap over the base cross when all leg tubes are assembled.
INTENDED USE
Functional floor stand with a height-adjustable bearing plate for placing
near-field monitors and loudspeakers
Thanks to its slim appearance, especially for home and studio use
FEATURES & CAPABILITIES
- Load-bearing capacity 35 kg (see safety instructions: section: C)
- The height of the monitor depends on the height of the bearing plate:
- settings are: min. 677 -732 -812 -892 -972 -1052 -max. 1132 mm
- Solid bearing plate with 4 self-adhesive rubber knobs:
- Plate sizes: Art. 25720: 205 x 245 mm; Art. 26722: 280 x 320 mm
- The extendable steel tube combination is double secured
- Internal cable routing is possible inside the tube (without plug, if necessary)
- The flat and stable 3-leg base construction with voluminous rubber floor protectors ensures acoustic decoupling with a firm stand
Thank you for choosing this product. Please read and follow the instructions
carefully. They inform you about all the important steps concerning assembly
and handling.
We recommend you to keep them for future reference.
SAFETY INSTRUCTIONS
A. GENERAL
- The stand should be visually inspected before and after use.
- Damaged or incomplete stands should not be used or only used after repair. A. – Please ensure that the floor is suitable, i.e. level and stable
- The thread points d.3 can cause injuries. Utmost caution is required during installation and handling. We recommend to wear protective gloves
- Keep unauthorized persons away
- Observe the instruction manual and keep it for future reference
B. MOUNTING INSTRUCTIONS
- Handle base tubes, tube combination and bearing plate with care and B. – do not drop (risk of crushing, damage to the floor, etc.)
- Make sure that the screw connections are tight (base, tubes, bearing plate)
C. LOAD-BEARING CAPACITY
- The max. load capacity of 35 kg applies exclusively to loads which act exactly vertically on the tube combination.
- This is NOT given..
- a. …with off-centre loads, i.e. the centre of gravity of the load is not directly above the tube combination,
- b. …when the stand is at an angle (e.g. when the floor is inclined or if the base tube is screwed loosely) as well as
- c. …in case of external influences and disturbances (tugging on the stand, shocks from passers-by, wind forces, vibrations, etc.)
This creates TILTING hazards which significantly reduce the specified load- bearing capacity of max. 35 kg.
D. EXTENDING/RETRACTING THE LOAD
-
Before extending/retracting, the monitor must be removed from the bearing D. – plate.
-
Directly screwed monitors can remain if you observe the following procedure
This should be always carried out by two competent persons (P1, P2)D.- D. – P1: holds the extension tube together with the load firmly and securely; D.
- P2: secures the selected height by engaging the safety hook 4.5 and tightening the clamping screw 4.6.
E. DISASSEMBLY
- Always lift the load from the stand first – only then start retracting or E. – dismantling the stand.
- Handle and store components with care.
SET-UP INSTRUCTIONS
-
COMPONENTS
After unpacking, visually check whether all parts are present and as far as can be detected – undamaged.-
a Tube combination consisting of:
a a.1 bottom disc, fixed, a.2 top disc, loose, a.3 cover cap,
a a.4 base tube , a.5 tension clamp, a.6 extension tube -
b 3x Leg tube with floor protector
-
c Bearing plate:
Art. 25720: 205 x 245 mm; Art. 26722: 280 x 320 mm -
d Accessories bag:
d d.1 4x rubber knobs ø 11 x 5 mm, d.2 M8 threaded shackle,
d d.3 panhead screw M8 x 20 mm, d.4 3x carriage bolt M6 x 35 mm, d d.5 3x locking nut M6, d.6 allen wrench SW5,
d d.7 hexagon wrench SW10/SW13 -
e Instruction manual
-
-
ASSEMBLY
STAND -
Place the leg tubes b between the two discs a.1, a.2 of the base tube a.4 (aligned holes!)…
-
.and connect them with each other: for this purpose, insert carriage bolts M6 x 35 mm d.4 from below and screw with lock nut M6 d.5 by using wrench SW10 d.7.
-
When the assembly of all 3 leg tubes is completed, the cover cap a.3 is pushed over the base cross.
BEARING PLATE -
Insert threaded shackle d.2 into the slot of the extension tube a.6…
-
…and hold in position with finger.
-
Place bearing plate c with central drill hole on the pull-out tube
-
Attention : The side rails of the bearing plate point downwards. 2.7 Insert panhead screw M8 x 20 mm d.3 through the center drill hole…
-
…and screw it to the threaded shackle d.2 using the Allen key d.6.
SUPPORT for the MONITOR
Ideally, only the membrane of the monitor vibrates. In practice, however, vibrations are also transmitted to the housing, the stand and the floor. In order to minimize this effect, you can use the enclosed rubber knobs d. 1 . 3.1 Remove protective film and stick them to the desired place on the plate.
USER INSTRUCTIONS / FUNCTIONS
ATTACHING THE LOAD / HEIGHT ADJUSTMENT
ATTENTION!
- Do not underestimate the weight of the speaker.
- The attachment as well as the extension/retraction of the load should be carried out by competent, i.e. technically and physically suitable personnel.
- Attentiveness and communication between the operators is essential .
- We strongly recommend first removing the monitor, then adjust and secure the height.
- The monitor is then reattached.
- If the monitor should remain on the stand, the extension and retraction must be carried out by at least two competent persons (P1, P2).
- It is valid:
- P1 holds and moves the loaded extension tube 4.2 / 4.5
- P2 handles the securing elements
- P2 safety hook 4.3 / 4.4 and wing nut 4.1 / 4.6
- Always hold the extension tube with a firm grip during height adjustment 4.2 and at the same time be ready to tighten the wing nut 4.6 immediately (e.g. in case of unintentional slipping of the extension)
EXTENDING
- Slightly loosen the wing nut Of the tension clamp a.5
- Lift the extension tube a.6, whereby
- the safety hook automatically unlocks (and remains in unlocked position).
- The safety hook must be actively pushed into the recess Of the extension tube.
- As soon as the hook is immersed, the tube is lowered by 2 mm, thus preventing an untended disengaging Of the safety hook.
- Retighten the wing nut.
RETRACTION
- Slightly loosen the wing nut Of the tension clamp a.5.
- First, lift the extension tube a.6 a little
- whereby the safety unW<s
- Subsequently, retract the extension tube and.
- push the safety hook back into the recess and let it hook into the extension tube.
- Retighten the wing nut.
CABLE ROUTING
The “open” design of the stand makes it possible to insert a cable into the tube.
PLACE & DIMENSIONS
- a Base tube bottom a (8 mm from the ground) b Extension protection
- b (ø 24 mm-Hole)
- c Extension tube top c (19 x 24 mm)
DIMENSIONS
CHECK, MAINTENANCE, CLEANING
- Careful handling of the extension tube maintains the telescoping, the load capacity and safety of the installation.
- During maintenance work – always in unloaded condition – pay attention for possible hazards (jamming, bumping, tipping over).
- For cleaning and maintenance, use a slightly damp cloth and a non-abrasive cleaning agent.
FAULT-FINDING (F) and REPAIR (R)
- F: Stand wobbles:
- R: Check if floor is level.
- R: Check base tube, discs a.1, 2, 3 and leg tubes b for levelness.
- R: Check tightness of the screws on the three leg tubes as well as
- R: on the tension clamp and retighten, if necessary.
- F: Extension tube a.6 retracts unintentionally:
- R: Press safety hook into recess and tighten wing nut (4.4-4.6).
- Monitor wobbles/sits crooked:
- R: Ensure that the stand is placed on a level floor.
- R: Check if the threaded connections of the stand (1. leg tubes – base tube,
- R: 2. tension clamp, 3. extension tube – bearing plate) are firmly tightened.
- R: Optimize supports d.1, i.e. ensure correct position and quantity (pcs. 4).
- R: Ensure suitability of the monitor in terms of shape and size.
- R: Always align the center of gravity of the monitor centrally to the bearing plate.
TECHNICAL DATA
Material
| Tubes, discs, safety hook as well as bearing plate: Steel black powder coated
Thread: Steel galvanised Clamp, shells, caps: PA-6 Floor protectors : TPE, 83Sh.A
---|---
Load-bearing| max. 35 kg centric load
Dimensions
| Root circle ø 690 mm, H = 38/48 mm Height: min. 677 – max. 1132 mm Bearing plate: Art. 25720: 205 x 245 mm
Art. 26722: 280 x 320 mm
Cardboard| L x W x H: 702 x 321 x 138 mm
Weight| Art. 26720 – 5,1 kg, Art. 26722 – 5,7 kg
References