KONIG MEYER 26750-022-55 Speaker Stand Instruction Manual
- June 12, 2024
- KONIG MEYER
Table of Contents
KONIG MEYER 26750-022-55 Speaker Stand Instruction Manual
26750 Speaker stand
INTENDED USE
This floor stand enables you to attach speakers and monitors Thanks to the attractive contemporary look plus the space-saving design the stand is especially suited for presentations, studio and home
FEATURES & CAPABILITIES
- Load-bearing capacity 35 kg (see safety instructions: section: C)
- Round, flat cast-iron base (ø 450 mm, 6.8 kg)
- Double secured steel tube combination
- Height adjustable from 930 – 1430 mm
- With cone-shaped mounting aid for 35/36 mm speaker enclosures
Thank you for choosing this product. Please read and follow the instructions carefully. They inform you about all the important steps concerning assembly and handling. We recommend you to keep them for future reference.
SAFETY INSTRUCTIONS
A. GENERAL
- The stand should be visually inspected before and after use.
- Damaged or incomplete stands should not be used or only used after repair.
- Please ensure that the floor is suitable, i.e. level and stable
- If necessary, remove the load before you change the position of the stand
- Keep unauthorized persons away
- Observe the instruction manual and keep it for future reference
B. MOUNTING INSTRUCTIONS
- Handle the base and tube combination with care and do not drop
- (risk of crushing, damage to the floor, etc.)
- Make sure that the screw connections are tight (base, tubes, load)
C. LOAD-BEARING CAPACITY
- The max. load capacity of 35 kg applies exclusively to loads which
- act exactly vertically on the tube combination.
- This is NOT given…
- …with off-centre loads, i.e. the centre of gravity of the load is not
- directly above the tube combination,
- b. …when the stand is at an angle (e.g. when the floor is inclined or
- b. if the base tube is screwed loosely) as well as
- c. …in case of external influences and disturbances (tugging on the
- c. stand, shocks from passers-by, wind forces, vibrations, etc.)
- This creates TILTING hazards which significantly reduce the specified
- load-bearing capacity of max. 35 kg.
D. EXTENDING/RETRACTING THE LOAD
- This should be always carried out by two competent persons (P1, P2)
- P1: holds the extension tube together with the load firmly and securely;
- P2: secures the selected height by engaging the safety hook 4.5
- P2: and tightening the clamping screw 4.6.
DISASSEMBLY
- Always lift the load from the stand first – only then start retracting or
- dismantling the stand.
SET-UP INSTRUCTIONS
-
COMPONENTS
After unpacking, visually check whether all parts are present and – as far as can be detected – undamaged.
a Base/floor plate ø 450 mm
b Tube combination consisting of:
b.1 M20 threaded bolt, b.2 base tube, b.3 tension clamp,
b.4 extension tube, b.5 mounting aid
c Instruction manual
-
ASSEMBLY
-
Lay out base plate a with felt pads facing downwards.
-
Screw the threaded bolt b.1 of the base tube into the
-
base plate a up to stop.
-
NOTE!
-
There should be no air gap between the tube and the plate.
-
Please check screw connection regularly for tightness and
-
retighten if necessary.
USER INSTRUCTIONS / FUNCTIONS -
CONNECTION LOAD – STAND
In order to attach the load (loudspeaker/monitor), it should be equipped with… -
a plug-in socket (ø 35/36 mm) or be upgraded with a corresponding part. You may use:
-
Mounting adapters (e.g. K&M 195/8, 24281)
-
Flange adapters (e.g. K&M 19654, 19656)
4./5. ATTACHING THE LOAD / HEIGHT ADJUSTMENT ATTENTION!
- Do not underestimate the weight of the speaker.
- The attachment as well as the extension/retraction of the load should be
- carried out by competent, i.e. technically and physically suitable personnel.
- Attentiveness and communication between the operators is essential.
- Always hold the extension tube with a firm grip 4.2 during the height adjustment.
- Be prepared to tightenthe wing nut 4.6 immediately (e.g. should the load unintentionally slip)
EXTENDING
We recommend that you first set the desired height, secure it and then attach the load. If this is not possible, a qualified person (P1) must hold the loaded extension tube while another person (P2) handles the securing elements safety hook 4.4 and wing nut 4.6.
-
Slightly loosen the wing nut of the tension
-
clamp b.3.
-
Lift the extension tube b.4, whereby…
-
…the safety hook automatically unlocks (and
-
remains in unlocked position).
-
The safety hook must be actively pushed into the
-
recess of the extension tube.
-
As soon as the hook is immersed, the tube is
-
lowered by 2 mm, thus preventing an untended
-
disengaging of the safety hook.
-
Retighten the wing nut.
RETRACTION
We recommend that you first remove the load and only then retract the extension tube. If this is not possible, a qualified person (P1) must hold the loaded extension tube, while another person (P2) operates the securing elements safety hook 5.5 and wing nut 5.6.
-
Slightly loosen the wing nut of the tension
-
clamp b.3.
-
First lift the extension tube b.4 a little…
-
…whereby the safety hook unlocks automatically
-
Subsequently, retract the extension tube and…
-
…push the safety hook back into the recess and
-
let it hook into the extension tube.
-
Retighten the wing nut.
DIMENSIONS
FAULT-FINDING (F) and REPAIR (R)
F: Stand wobbles:
R: Check if floor is level.
R: Check if base plate is level.
R: Check tightness of the screws on the base tube and tension clamp and
retighten, if necessary.
F: Extension tube b.4 retracts unintentionally:
R: Press safety hook into recess and tighten wing nut (4.4-4.6).
F: Loudspeaker/monitor sits crooked:
R: A small air gap between extension tube and mounting or flange adapter
is normal and necessary to prevent the speaker from wedging. This can lead to
a slightly crooked fit of the box.
R: The installing of the levelling adapter 85890 fills the air gap.
R: US boxes have a diameter of 38.1 mm (1 -1/2″). This deviation is
R: compensated by using the adapter sleeve 21326.
CHECK, MAINTENANCE, CLEANING
- Careful handling of the extension tube maintains the telescoping, the load capacity and safety of the installation.
- During maintenance work – always in unloaded condition – pay attention for possible hazards (jamming, bumping, tipping over).
- For cleaning and maintenance, use a slightly damp cloth and a non-abrasive cleaning agent.
TECHNICAL DATA
Material| Base/floor plate: Cast iron, black powder coated Tubes, safety hook:
Steel black powder coated Thread: Steel galvanised Clamp, shells, caps: PA-6
---|---
Load-bearing capacity| max. 35 kg centric load
Dimensions| Base/floor plate: ø 450 mm, H = 21 mm Tube combination: ø 42 / ø
35 mm Height: min. 930 – max. 1430 mm (5 x 100 mm)
Cardboard| L x W x H: 1010 x 100 x 55 mm
Weight| net: 8.5 kg, gross: 9.1 kg
KÖNIG & MEYER GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de
26750-022-55 Rev.04 03-80-864-00 4/22
References