GENERAL INFORMATION

Safety Icon NO FROST

Safety Icon NOT SUITABLE FOR CHILDREN
Safety Icon OUTDOOR
DO NOT PUT UNDER WATER

DO NOT INSTALL IN THE VALVE BOX

TO BE INSTALLED OUTDOORS

Safety Icon

Always keep the cover closed
Cover Closed

Tip Icon  FILTERED WATER

Use water from the mains tap or filter the water before using it.

DUPLO is used to set the watering of two lines (A and B) using 6 daily watering programmes. Each line can have up to three watering cycles programmed per day. Programmes “1”, “3” and ”5” are dedicated to line A, programmes “2”, “4” and ”6” to line B.

DESCRIPTION
Product Overview

  1. Inspectable and washable filter
  2. 3/4” F tap connector
  3. Ring nut
  4. Liquid Crystal Display
  5. Back button
  6. Forward button
  7. Enter button
  8. Protective cover
  9. 1/2″ threaded male connector
  10. uick-Click male connector

CONDITIONS OF GUARANTEE

This device is guaranteed for 3 years from the date of purchase as indicated by the invoice, bill or till receipt issued at the time of  the transaction, which must be kept. Claber guarantees that the product is free of material or manufacturing defects. Within two years from the date of delivery to the consumer, Claber shall repair or replace any parts of this product found to be defective. The warranty is void in the event of:

  • Lack of proof of purchase (invoice, receipt or cash register receipt);
  • Use or maintenance different from what is specified;
  • Disassembly or tampering by unauthorised personnel;
  • Faulty installation of the product;
  • Damages from atmospheric agents or contact with chemical agents; Claber accepts no liability for products that it has not manufactured, even if used in combination with its own products. The costs and the risks associated with shipment are met entirely by the owner. Assistance is provided by Claber authorized service centres.

BATTERY REPLACEMENT

Battery Replacement
Battery Replacement
BATTERY NOT INCLUDED

Battery Charging
Battery Cover
Battery Instruction

Only use new 9 V Alkaline 6LR61 batteries, with an expiry date exceeding one year and that have never been used. Replace the battery at the beginning of each season. When the battery is completely flat, the water timer automatically stops its functions and closes the valve. Never replace the battery during irrigation, otherwise the water will continue to flow at the end of the cycle. After the battery has been replaced, reset the date and time. Programming is saved

RAIN SENSOR (optional)

Product Instruction
Remove the bridge connector on the timer (1) and insert the Rain Sensor connector (2). Irrigation will not start if the container is full (at least 5 mm of rainfall). The irrigation cycle in progress will not stop

INSTALLATION

product Installation

Do not install the water timer inside valve boxes, below ground level or indoors. Do not use th e water timer with operating pressures lower than 0.5 bar (7.3 psi) or higher than 10 bar (145 psi).

MAINTENANCE

product Installation

http://claber.it/q.asp?q=istprg

WARNING – RECOMMANDATIONS

Read this instruction manual carefully and keep it handy for future reference. This device has been designed and manufactured exclusively for the setting of watering time by adults with experience and knowledge. Any use other than that described in this manual is considered improper: the manufacturer acknowledges no liability for damages arising from improper use, which will also void the warranty. Do not power the water timer with sources other than those specified.It is good policy – when the water timer is used for the first time

  • to make certain that the programmes run correctly. Do not use the water timer with chemicals or liquids other than water

At the end of the season, before the winter frosts, disconnect the timer from the tap, remove the battery and store the timer in a sheltered place, away from damp, where the temperature does not fall below 3°C.

ÉLIMINATION

The symbol in question applied to the product or the packaging indicates that the product must not be considered as normal domestic waste, but must be taken to a special centre for the collection and recycling of waste electrical and electronic equipment. Take care to dispose of this product in the proper way; this will help to avoid the negative consequences that could arise from unsorted collection or dumping. For more detailed information on the recycling of this product, contact the municipal authority, the local refuse collection service or the dealer from whom the item was purchased.

Declaration of Conformity

Assuming full responsibility, we declare that the product

the Declarations of Conformity accessible via the following link.

www.claber.com/conformity/

https://www.claber.com/conformity/
Fiume Veneto, 11/2022
Signature
LEGENDA – KEY
Battery using Instruction

FIXED: set programme active.
FLASHING: programme in function (watering in progress)

  1. In programming, indicates that the hour refers to: OPEN=start, CLOSED=end of automatic watering On the Manual page, indicates that the valve is: OPEN, CLOSED
  2. OPEN=start, CLOSED=end of automatic watering
  3. Indicates the hour or the start/end time of watering
  4. Indicates change settings
  5. Indicates the request to press a button
  6. Days of the week. Option to choose the day. (example: 1= Sunday
  7. Indicates the battery level
  8. Indicates the programme that we are working on
  9. Manual watering page

SETTINGS MODE

Setting Mood

Access the editing of the displayed setting

SETTINGS SEQUENCE

Setting Date And Time
PAGINA ORA – TIME PAGE
SETTING THE DAY/TIME

Holding the button pressed down, the time will progress faster
Setting Date And Time

SETTINGS SEQUENCE
Setting

SETTING THE OPENING/CLOSING TIME

All programmes are set in the same way. The programmes must be set in sequence in time order within the same 24 hour period (e.g. 20:00 ĺ 21:00 pm OK ĺ 19:00 pm NO). The timer progresses automatically by 1 minute in both OPEN and CLOSED mode

Setting opening prog. 1 LINE A
Setting  TIME
Setting closing prog. 1 LINE A
Setting Closing

PROGRAMMA SETTIMANALE – WEEKLY

Timer

Press one of the arrows and position the cursor under the day you want to enable/disable. Press ENTER. To exit, position the cursor on EXIT and press ENTER. The days set apply to both lines.
Timer
MANUAL
Timer

Press the left arrow to start irrigation
Timer

15 MIN

Each time the button is pressed, the irrigation times increases by 5 minutes up to a maximum of 60 minutes

20 MIN


Press the right arrow to stop the cycle early
Press Right Arrow

How many minutes can an irrigation cycle be set to run for?
The total run time of all set irrigation programmes cannot exceed 23 hours and 59 minutes. The minimum time a programme can be set to is 1 minute.
I want to distinguish between the irrigation days for the two lines.
It is not possible to distinguish between the set days: the settings apply to both lines.
I want to delete a programme.
To delete a programme, switch to CLOSED mode, press ENTER, then press the two arrows together.
I only want to set parts of the system (e.g. only line B).
To set a part of the system only, you need to set the times of the other programmes in sequence, and then go back and delete the ones you do not want.

I want to fully reset the timer.
To fully reset the timer, press and hold the two arrow buttons together for at least 10 seconds.
How long can manual irrigation be set to run for?
Manual irrigation can be set to between 15 and 60 minutes.
The timer only works in manual mode, what should I do?
Check that the bridge connector on the timer or the connector on the Rain Sensor are inserted correctly.

CLABER SPA – Via Pontebbana, 22 – 33080 Fiume Veneto PN – Italy
Tel. +39 0434 958836
Fax: +39 0434 957193
info@claber.comwww.claber.com

Represented by: Authorised Rep Compliance Ltd., ARC House, Thurnham,
Lancaster, LA2 0DT, UK.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals