Surgical Glove
Instruction Manual
Glove for single use compliant with PPE regulation (EU) 2016/425, EN 420, and EN ISO 374
INSTRUCTIONS FOR USE
Instructions for use are to be used in combination with the specific product-
related information on each product packaging. The gloves are sold as a
bundled unit within the shipping carton. In case this bundled unit is
dismantled and products are sold separately, the distributor must ensure that
the instructions for use are accompanied by each separate unit.
The gloves are classified as Personal Protective Equipment (PPE) Category III
according to PPE Regulation (EU) 2016/425 and have been shown to comply with
this regulation through the applicable harmonized European standards. These
gloves are designed to provide protection against specific chemicals tested,
microorganisms, and particulate radioactive contamination (if applicable). The
gloves meet the EN/ISO standards shown on each specific packaging. This PPE is
single-use only and is to be disposed of after contamination.
EXPLANATION OF STANDARDS AND PICTOGRAMS
EN ISO 374-1
Permeation levels are based on breakthrough times (tested acc. EN
16523-1:2015) as follows:
Type A / B / C
Permeation level acc. EN ISO 374-1:2016 +A1:2018
Minimum breakthrough time in minutes
1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|
10 | 30 | 60 | 120 | 240 | 480 |
ABCDEFGHIJKLMNOPST
Type A = chemical breakthrough time > 30 minutes against at least 6 chemicals
from the list
Type B = chemical breakthrough time > 30 minutes against at least 3 chemicals
from the list
Type C = chemical breakthrough time > 10 minutes against at least 1 chemical
from the list
TEST CHEMICALS:
A = Methanol / B = Acetone / C = Acetonitrile / D = Dichloromethane / E =
Carbon disulphide / F = Toluene / G = Diethylamine /
H = Tetrahydrofuran / I = Ethyl acetate / J = n-Heptane / K = Sodium hydroxide
40 % / L = Sulphuric acid 96 % / M = Nitric acid 65 % /
N = Acetic acid 99 % / O = Ammonium hydroxide 25 % / P = Hydrogen peroxide 30
% / S = Hydrofluoric acid 40 % /
T = Formaldehyde 37 %
EN 374-4:2013
The degradation (in %) indicates the change in puncture resistance of the
gloves after exposure to the respective challenge chemical.
This information does not reflect the actual duration of protection in the
workplace and the differentiation between mixtures and pure chemicals. The
chemical resistance has been assessed under laboratory conditions from samples
taken from the palm only and relates only to the chemical tested. It can be
different if the chemical is used in a mixture. It is recommended to check
that the gloves are suitable for the intended use because the conditions at
the workplace may differ from the type test depending on temperature,
abrasion, and degradation. When used, protective gloves may provide less
resistance to dangerous chemicals due to changes in physical properties.
Movements, snagging, rubbing, degradation caused by chemical contact, etc. may
reduce the actual use time significantly. For corrosive chemicals, degradation
can be the most important factor to consider in the selection of chemical-
resistant gloves. Before usage, inspect the gloves for any defects or
imperfections.
EN ISO 374-5: 2016
Tested for resistance to penetration according to EN 374-2:2014
Tested for resistance to penetration by blood-borne pathogens according to EN
ISO 374-5 / ASTM F1671 (virus resistance).
Resistance to bacteria and fungi – pass
Resistance to the virus – pass
The penetration resistance has been assessed under laboratory conditions and
relates only to the tested specimen.
XXXX = Identification number of notified Body responsible for the EU-type examination and supervising ongoing conformity.
PRECAUTIONS FOR USE
Always check the gloves for possible mechanical damage, e.g. holes or tears,
before use. Do not use damaged gloves. Glove length is appropriate to the end
user where the risk to the wrist area is minimal.
**TEMPERATURE LIMIT
STORAGE INSTRUCTIONS
Keep storage area cool, dry, and dust free, avoid ventilation and storage
close to photocopy equipment. Protect gloves against ultraviolet light
sources, sunlight, oxidizing agents, and ozone. Store in original packaging
according to the temperature limit provided on the packaging.
EN 421:2010
** Protection against particulate radioactive contamination.
These gloves do not protect against mechanical risks.
PPE is for single-use only and must not be reused.
EN 420:2003+A1:2009
Before usage read instructions for use carefully.
INGREDIENTS / HAZARDOUS INGREDIENTS
Some gloves might contain ingredients that are known to possibly cause skin
irritations or allergic reactions in sensitized persons. Check warning
information on specific packaging carefully. The formulation is available on
request.
DISPOSAL INSTRUCTIONS
Dispose of the gloves in accordance with the valid regulations for this
material.
Gloves contaminated with chemical substances must be disposed of in accordance
with the regulations for the relevant chemicals.