better bathrooms TAMDLCHR Twin Lever Chrome Kitchen Mixer Tap User Manual
- June 12, 2024
- Better Bathrooms
Table of Contents
Product name Kitchen Taps/TAMDLCHR
User Manual
TAMDLCHR Twin Lever Chrome Kitchen Mixer Tap
Thank you for choosing Better Bathrooms.
Please read this manual before installing your product and keep for future
reference.
- Single -person assembly
- Tools required
- We always recommend using professional tradespeople to install your product
Important information
- Please read these instructions thoroughly and retain for future reference
- Pressures should meet minimum stated on the website
- Pressures must be balanced for optimum performance
- Always check for pipes and cables before drilling
Water Pressure:
We recommend a minimum water pressure of 0.5Bar and a maximum of 5 Bar to
ensure efficient operation of your product.
Flow rate:
0.5(bar) | 1(bar) | 2(bar) | 3(bar) |
---|---|---|---|
6.5 L/M | 9.3 L/M | 13.1 L/M | 16.1L/M |
Installation Guide
Follow these instructions before fitting the tap detailed in this guide.
Prior to installation, please check that your plumbing system is
adequate and that all pipes have been sufficiently flushed through.
The installer should open supply pipes in the house and empty the water into a
bucket to clear any debris before the tap is fitted.
-
Turn off the mains cold water supply. The mains stopcock is usually found where the supply enters the building.
-
It is also recommend that any hot water heating systems are turned off.
-
Drain the hot and cold water systems. To ensure complete drainage, open all taps.
-
Position the tap over the hole, ensuring the rubber seal is positioned properly between the tap body and the sink. Or in the case that the product includes a base plate ensuring the rubber seal is between the base plate and the sink.
-
Using the fixing nut(s) supplied, screw the short threaded bar(s) into the hole(s) on the underneath of the body.
-
Next, screw the flexi tails in to each of the other holes (ensure these are screwed in firmly). Please make sure the threaded bar(s) are fully through sink hole. Please also note the connector has linked correctly, the cold supply must be on the right and hot supply on the left.
Please note that the flexi-tails should not be tightened using a spanner, as this can damage the O ring. -
To comply with water regulations, isolating valves should be fitted in the pipe work beneath the tap. This enables each supply to be independently isolated which makes it easier to service and /or remove the tap. Isolation valves” are not supplied
Once all the connections are made, the mains water supply can be turned back on and the system refilled. -
Now check for any leaks. All water heating systems may now be turned on.
Diagrams
Installation Step
Troubleshooter Guide
Tap dripping for short period after closure : This is normal as the spout is
emptying Tap dripping continually : Turn off the water supply, remove the flow
control valve and clean and check internal seat for debris
No water coming through : Check pipes and inside of mixer for blockages
Water not mixing: Pressures should be balanced or the higher pressure will
restrict the lower
Valves become stiff : remove valves and clean out debris
Cleaning
To maintain the surface finish of your product, wipe clean regularly, using a clean damp cloth and dry cloth to polish. Do not use abrasive cleaning agents or materials on the product surface as you may invalidate your guarantee. Should any harsh chemicals come into contact with the surface of the product during bathroom cleaning, rinse off immediately, wipe clean and dry.
For more information
visit betterbathrooms.com
email
customerservices@buyitdirect.co.uk
call 0330 390 3062
Read User Manual Online (PDF format)