WARNING:

  1. To ensure optimal performance, avoid allowing the pump to operate without water.
  2. Keep the controllerin a dry place and prevent it from being exposed to water splashes.
  3. Exercise caution when assembling the magnet base. Place it parallel to the pad close to the outside wall of the fish tank to avoid damaging the fish tank.hygger HG070 Cross Flow Wave Pump - Figure 1
  4. Do not attempt to disassemble the controller or adapter without professional guidance.

INTRODUCTION

hygger wave makers are expertly designed to stimulate a natural sea environment using advanced technology, providing a natural habitat for various aquatic organisms in the fish tank or pond. Before assembling and operating correctly, please read the manual carefully.

PRODUCT FEATURES

  • Unique control system offers multiple functions and the ability to create various wave patterns, providing a natural environment for different sea creatures
  • Built-in wireless controllers allow synchronize operation among wave makers. One main controller can remotely control the slave-controllers, providing a convenient and easy-to-use system.
  • Low voltage DC electronic pump with variable frequency provides a safe operating environment for users.
  • Easy operation to achieve multiple sea movements.
  • Flow direction can be adjusted by different modes needed, providing maximum flexibility and customization.
  • Large range of voltage input (AC100~240V 50/60Hz) allows to operate in various power system and prevents the impact on waves.

PRODUCT SPECIFICATIONS

Model HG070-12W HG070-18W HG070-25W
Voltage Input: AC100-240V 50/60Hz

Output: DC24V
Flow rate (GPH)| 1321GPH (5000L)| 1850GPH (7000L)| 2380GPH (9000L)
Recommend tank size| ≤60CM (60Gal)| ≤80CM (135GaI)| ≤100CM (265GaI)
Recommend glass thickness| ≤0.315″ (8MM)| ≤0.39″ (10MM)| ≤0.47″ (15MM)

CONTROLLER DIAGRAM

hygger HG070 Cross Flow Wave Pump - Controller Diagram A. Buttons
MODE/FREQ: Press briefly to select each function mode, press and hold to set frequency.
OFF/FEED: Press to turn on and off; press and hold to enter the Feed mode.
Wi-Le/NIGHT: Press the button to set Master control, Slave control or operate individually; press and hold to enter the Night Mode.
“+/-”: Adjust any model increase or decrease.

B. Function Description
Master Control: Press “Wi-Le/NIGHT” once to enter the Master Control model, the “M(Master)” icon will appear. Master controller can operate all functions.
Slave Control: Press “Wi-Le/NIGHT” until the “S(Slave)” icon appears to enter into Slave mode, Among two or more wave makers in a group, set one controller as the Master Control and the other as Slave Control. All pumps will keep the same performance by adjusting the Master controller.
C. Introduction of each mode
M1: Classic Wave Pulse Mode
One or more pumps can be used at the same time, press the “+” and “-” keys to adjust flow, long press “MODE/FREQ” to adjust the frequency.
M2: Sine Wave Mode
One or more pumps can operate at the same time in this mode. The flow rate varies from 30% to 100% as a sine curve. Long press “MODE/FREQ” to adjust the frequency.
One or more pumps can make a constant flow at the same time. Flow rate can be adjusted by “+” and *-”.
M3: Constant Wave Mode
One or more pumps can make a constant flow at the same time. Flow rate can be adjusted by “+”and “-” keys.
M4: Random Wave Mode
One or more pumps can operate at the same time. Pump power changes randomly and irregularly.
M5: Classic Wave Cross-flow Mode
One or more pumps can be used at the same time, Adjust the flow rate with the “+” and “-” keys and the frequency with a long press of “MODE/FREQ”.
D. Feed Mode Function
Long press the “Wi-Le/FEED” button, pump stops working for 10 minutes to feed, then restarts automatically. To resume working during feeding, long press the “Wi-Le/FEED” button again, then current setting will be displayed.
E. Night Mode
Long press the “Wi-Le/NIGHT” button to enter night mode. Press and hold again to exit Night Mode. Night Mode: automatically switches to constant flow mode with the lowest flow rate.
F. Key Locking Function
Long press the “+” and “-” keys until lock icon appears in the upper right corner of the screen, to lock all function keys. To unlock, long press the “+” and “-” keys until lock icon disappears.

MAINTAINING

  1. Clean the controller regular to ensure optimal performance.
  2. If water comes into controller, wipe the surface with a dry cloth to prevent damage.
  3. Remove the debris in the pump by rotating the basket counterclockwise to open and clockwise to lock.
  4. Use a soft cloth to clean the blades and remove any dirt buildup in the pump.
  5. This product is for indoor use only, don’t submerge it in the water to avoid unnecessary loss.

Appendix: PUMP LOCATING hygger HG070 Cross Flow Wave Pump - PUMP
LOCATING

Trouble Shooting

Error code Fault Solution
Er01 Controller over urrent Abnormal work current detected, check if the

pump is short of voltage or if the controller is broken.
Er02| Controller over temperature| Check whether the controller is exposed to sunlight or in a high temperature environment.
Er04| Pump blockage| The impeller stops running, clean the pump and impeller to ensure the impeller is clean and working.
Er05| Controller over voltage| Check the input supplying voltage
Controller under voltage

DISPOSAL

Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. This product has to be disposed of at an authorized place for the recycling of electrical and electronic appliances rather than being disposed of together with the domestic waste. Collecting and recycling waste is a way of saving natural resources. So, please consult with your local seller to make sure the productis disposed of in an environmentally friendly way.

PACKING LIST

  • 1x Wave pump
  • 1x DC adapter
  • 1x LCD controller with holder
  • 1x User manual

CONTACT INFORMATION

Company Name: Shenzhen Mago Trading Co., Ltd
Add: Bantian Group Business Central, Longgang District, Shenzhen City, Guangdong Province, China
Website: www.hygger-online.com
E-mail: Mago@hygger-online.com
If you have any problem, please provide your invoice and shipping address by E-mail: mago@hygger-online.com

| E-CrossStu GmbH
Mainzer Landstr.69,Frankfurt am Main, Baden-Wiirttemberg,60329,Germany
E- CrossStu@web.de
+49 69332967674
---|---
| YH Consulting Limited
C/O YH Consulting Limited Office
147,Centurion House,London Road, Staines—upon—Thames,Surrey,
TW18 4AX,London
H2YHUK@gmail.com
+44 07514-677868

hygger HG070 Cross Flow Wave Pump - Symbol 3 MADE IN CHINA

Documents / Resources

| hygger HG070 Cross-Flow Wave Pump [pdf] User Manual
HG070 Cross-Flow Wave Pump, HG070, Cross-Flow Wave Pump, Flow Wave Pump, Wave Pump, Pump
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals