SUNCO LIGHTING LED Flood Light Installation Guide

June 12, 2024
Sunco Lighting

SUNCO LIGHTING LED Flood Light

SUNCO-LIGHTING-LED-Flood-Light-PRODUCT

Product Information

The LED Flood Lights are a type of luminaire that provides powerful and energy-efficient lighting. These flood lights are designed for outdoor use and are commonly used for illuminating large areas such as gardens, driveways, and sports fields. The lights come with a heavy-duty XC1 cover for added durability and protection against harsh weather conditions.

Product Usage Instructions

  1. Before installation, it is important to find a qualified electrician to ensure proper installation and safety.
  2. Read the instructions provided in the user manual before installing and using the luminaire.
  3. Warning: To prevent the risk of fire or electrical shock, always disconnect power before installing or servicing the flood lights.
  4. Caution: To avoid any injuries, follow the recommended precautions and operating instructions.
  5. Arm Mounting:
  6. Seal the arm thread using teflon tape or silicone sealant.
  7. Secure the LED Flood to a 1/2” NPS hole in a junction box or landscape post. Make sure to use the provided heavy-duty XC1 cover.
  8. Plug all unused holes and seal threads with silicone depending on the mounting location.
  9. Standard Wiring:
  10. For fixtures with a universal voltage driver, connect the black fixture lead to the (+) LINE supply lead.
  11. Connect the white fixture lead to the (-) COMMON supply lead.
  12. Connect the GROUND wire from the fixture to the supply ground.
  13. Cleaning & Maintenance:
  14. Ensure the fixture temperature is cool enough to touch before cleaning or maintaining it.
  15. Clean the lens and fixture using a non-abrasive glass cleaning solution.
  16. Do not open the fixture to clean the LED and avoid touching theLED directly.
  17. Troubleshooting:
  18. Check that the line voltage at the fixture is correct. Refer to the wiring directions for guidance.
  19. Ensure the fixture is properly grounded.

PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the luminaire.

OPERATING INSTRUCTIONS

WARNING, CAUTIONS AND OPERATING INSTRUCTIONS

  • To reduce the risk of death, personal injury or property damage from fire, electrical shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Commercial installation, service and maintenance of luminaries should be performed by a qualified licensed electrician.
  • For the installation: If you are unsure about the installation or maintenance of luminaries, consult a qualified licensed electrician and check your local electrical code.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other objects.
  • Do not make or alter any holes in an enclosure of wiring or electrical components during kit installation.

WARNING: RISK OF FIRE OR ELECTRICAL SHOCK

  • Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
  • Turn off the power when you perform any maintenance.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code and any applicable local code requirements.
  • All wiring connections should be capped with UL approved wire connectors.

CAUTION: RISK OF INJURY

  • Avoid direct eye exposure to the light source while it is on.
  • Account for small parts and destroy packing material, as these may be hazardous to children.
  • Suitable for Wet locations, IP65.

WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

ARM MOUNTING

  1. Seal arm thread using teflon tape or silicone sealant.
  2. Secure the LED Flood to a 1/2’’ NPS hole in a junction box or landscape post. Heavy duty XC1 cover provided.
  3. Plug all unused holes and seal threads with silicone.
  4. The swivel arm on the LED Flood allows 180° vertical aiming adjustment depending on mounting location.

STANDARD WIRING

Universal voltage driver permits operation at 120V to 277VAC, 50 or 60 Hz except fixtures factory ordered with a (PC)

  1. Connect the black fixture lead to the (+) LINE supply lead.
  2. Connect the white fixture lead to the (-) COMMON supply lead.
  3. Connect the GROUND wire from fixture to supply ground.

CLEANING & MAINTENANCE

CAUTION: Be sure fixture temperature is cool enough to touch. Do not clean or maintain while fixture is energized.

  1. Clean lens & fixture with non-abrasive glass cleaning solution.
  2. Do not open fixture to clean the LED. Do not touch the LED.

TROUBLESHOOTING

  1. Check that the line voltage at fixture is correct. Refer to wiring directions.
  2. Is the fixture grounded properly?