PLIANT TECHNOLOGIES PAC-MC4W-IO 4 Wire In/Out Headset Adapter User Guide
- June 12, 2024
- PLIANT TECHNOLOGIES
Table of Contents
PLIANT TECHNOLOGIES PAC-MC4W-IO 4 Wire In/Out Headset Adapter
Product Information
The 4-Wire I/O Headset Adapter is a device manufactured by Pliant Technologies. It is designed to be compatible with the MicroCom XR BeltPack. The adapter allows users to connect their wired intercom system to the belt pack, enabling communication between different devices. The adapter features LED indicators for power status and PTT engagement.
Product Usage Instructions
To connect the 4-Wire I/O Headset Adapter to a wired intercom system, follow these steps:
- Ensure that all equipment is powered off.
- Connect the 3.5 mm end of either the CAB-4W-WI or the 3.5 mm to 3.5 mm audio cable to the wired intercom connection on the headset adapter.
- Connect the other end of the cable into the 4-Wire In/Out connection of the wired intercom system.
- Connect a beltpack to the headset adapter using the attached cable.
- Make sure the orientation of the connections is correct.
- Set the In/Out volume/gain levels of the wired intercom system to the center position.
- Power on all attached equipment.
- Adjust the beltpack volume and wired intercom volume/gain levels as needed.
Please refer to the pin out connections provided for the CAB-4W-WI cable when making connections:
3.5 mm | RJ45 |
---|---|
– | 1 |
– | 2 |
T | 3 |
R | 4 |
S | 5 |
– | 6 |
– | 7 |
– | 8 |
For further information and additional documentation on the MicroCom XR and the 4-Wire I/O Headset Adapter, please visit the Pliant Technologies website. You can also contact their customer support via phone, email, or live chat during their designated hours of operation.
Parts description
IN THIS BOX
WHAT’S INCLUDED WITH THE 4-WIRE I/O HEADSET ADAPTER?
- PAC-MC4W-IO: Pliant 4-Wire In/Out Headset Adapter
- CAB-4W-WI: 3.5 mm TRS to RJ45 cable
- 3.5 mm to 3.5 mm Audio Cable
- USB-C Charging Cable
- Quick Start Guide
ACCESSORIES
OPTIONAL ACCESSORIES
- Selection of compatible dual-mini (DMG) headsets (see Pliant website for more details)
OPERATION
4-Wire In/Out Headset Adapter
LED Indicators
Power LED turns Blue | Power ON |
---|---|
Power LED OFF | Power OFF |
Power LED turns Red | Charging |
Power LED OFF | Fully Charged |
PTT LED turns Red | PTT Engaged |
Connect to a Wired Intercom
- Verify all of the equipment is powered off.
- Connect the 3.5 mm end of either the CAB-4W-WI or the 3.5 mm to 3.5 mm audio cable to the wired intercom connection on the headset adapter.
- Connect the other end into a wired intercom system’s 4-Wire In/Out connection.
- Connect a beltpack using the cable attached to the headset adatper. Note: Correct orientation as shown to the right.
- Set the In/Out volume/gain levels of the wired intercom in the center position.
- Power on all attached equipment.
- Adjust the beltpack volume and wired intercom volume/gain levels as needed.
CAB-4W-WI CABLE
Pin Out Connections
3.5 mm| RJ45
–| 1
–| 2
T| 3
R| 4
S| 5
6
–| 7
–| 8
CUSTOMER SUPPORT
Pliant Technologies offers technical support via phone and email from 07:00 to
19:00 Central Time (UTC−06:00), Monday through Friday.
1.844.475.4268 or +1.334.321.1160
customer.support@plianttechnologies.com
You may also visit our website (www.plianttechnologies.com) for live chat
help. (Live chat available 08:00 to 17:00 Central Time (UTC−06:00), Monday
through Friday.)
Additional Documentation
This is a quick start guide. For additional documentation on MicroCom XR,
visit our website. (Scan this QR code with your mobile device to navigate
there quickly.)
COPYRIGHT © 2021-2023 Pliant Technologies, LLC. All rights reserved. The
Pliant™ word mark and the Pliant “P” logo are registered trademarks of Pliant
Technologies, LLC. Any and all other trademark references within this document
are property of their respective owners.
Document Reference: D0000627_B
Only compatible with the MicroCom XR BeltPack.
For more information visit
www.plianttechnologies.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>