Thank you for purchasing the Platinum Ignition. This user guide contains important information for the safe installation and operation of your product. Please read this guide thoroughly before installation and/or operation to ensure proper usage.

PRODUCT WARNINGS

  • WARNING: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
  • WARNING: For Outdoor Use Only. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
  • WARNING: If the information in this guide is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
  • DANGER: This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car, or home.

INSTALLER: Leave this user guide with the appliance.
CONSUMER: Retain this user guide for future reference.

IMPORTANT PRODUCT WARNINGS

DANGER: FIRE OR EXPLOSION HAZARD

If you smell gas:

  • Shut off gas to the appliance.
  • Extinguish any open flame.
  • If odor continues, leave the area immediately.
  • After leaving the area, call your gas supplier or fire department.
  • Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.

WARNING

  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances.
  • An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

WARNING: For Outdoor Use Only.

  • Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: If the information in this is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

DANGER

CARBON MONOXIDE HAZARD

  • This appliance can produce carbon monoxide which has no odor.
  • Using it in an enclosed space can kill you.
  • Never use this appliance in an enclosed space such as a camper, tent, car, or home.

INSTALLER: Leave this user guide with the appliance.
CONSUMER: Retain this user guide for future reference.

The installer is responsible for using the correct fuel line sizing and/or regulation to provide gas within the specified minimum and maximum gas inlet pressures of the fire feature.

GENERAL INFORMATION

This Owner’s Guide and User Guide contains critical information for the safe installation and operation of your Platinum Ignition. You must read this user guide in its entirety prior to installation and/or operation. Failure to follow these instructions may result in property damage, personal injury, or death.

WARNING

HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.

  • Young children should be carefully supervised when they are in the area of the appliance.
  • Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance.
  • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier. It is the installer’s responsibility to read thoroughly before installing or servicing this equipment to ensure a safe installation and to educate the end user as to proper operation. Warming Trends is not responsible for damage due to improperly installed or operated units. Installers must leave this user guide with the end user. Instructions are updated as needed, and it is the installer or owners’ responsibility to periodically review Warming Trends website for applicable updates (www .Warming-Trends.com) Please keep this with your important papers.

WARNING

  • Do not use appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
  • Product is not intended to be used to burn wood or other combustibles. Solid fuels shall not be burned in the appliance.
  • Do not put any combustible materials into the fire feature.
  • Only use Liquid Propane or Natural Gas as specified for your Warming Trends appliance or burner. Do not use an alternative fuel.

CODE REQUIREMENTS

It is the responsibility of the installer to consult with the local municipality and to FOLLOW ALL LOCAL CODES concerning the installation and operation of the fire feature.

For systems with Platinum Ignition:

When the appliance is for connection to a fixed piping system, the installation must conform with local codes, or in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1·NFPA54; National Fuel Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, CSAB149.2, as applicable.

MINIMUM AND MAXIMUM GAS INLET PRESSURES

The installer is responsible for using the correct fuel lines and/or regulation to provide gas to the fire feature within the specified minimum and maximum gas inlet pressures below:

GAS PRESSURE REQUIREMENTS

PRESSURE NATURAL GAS PROPANE
Minimum 3.5” W.C. / .8718 Kpa 8.0” W.C. / 1.9927 Kpa
Nominal 7.0” W.C. / 1.7436 Kpa 11.0” W.C. / 2.7399 Kpa
Maximum 14.0” W.C. / 3.4872 Kpa 14.0” W.C. / 3.4872 Kpa

ELECTRICAL REQUIREMENTS

WARNING

  • Platinum Ignition System operates on 24 Volts AC power ONLY
  • DO NOT Attempt to Power using 110 Volts AC Power – Damage WILL RESULT

ELECTRICAL CONNECTIONS

To ensure proper operation of the Platinum Ignition, it is crucial to use the supplied 24 Volt Class II 50-Watt Transformer. If an alternative transformer is utilized, it must be a Class II 24 VAC, 3 amp, 50 Watt, or larger to meet the unit’s requirements. For installations with a total line length up to 50 feet, a minimum of 14 gauge wire should be used, while 12 gauge wire is recommended for installations up to 100 feet. For optimal results, it is highly recommended to utilize dielectric grease or silicon to fill all wire nuts employed during the Platinum installation.

WIRING OF MULTIPLE PLATINUM IGNITIONS

  • When connecting multiple Platinum Ignitions, each unit has a blue and a yellow wire for power connection. These are the power wires. When multiple Platinum Ignition are connected, the polarity between them must be the same.
  • To maintain correct polarity, it is necessary to connect all the blue wires to one wire from the transformer, and all the yellow wires to the other wire from the transformer.

Note: When connecting two units, it is essential to use a higher output transformer.

CONTROL BOX LAYOUT

PLATINUM INSTALLATION INSTRUCTIONS

If the Pilot Assembly for the Platinum Ignition is not installed on the Plate or Pan, start here for complete installation instructions. If your Plate or Pan does not have Precut Knockouts, skip to Step 2. If the Pilot Assembly has been installed on the plate or pan, skip to Step 3 below for installation instructions.

INSTALLATION OF THE PLATINUM IGNITION PILOT ASSEMBLY TO THE PLATE USING PRE-CUT KNOCKOUTS

The Plate or Pan that was included with your burner should have pre-cut pilot assembly knockouts for various burners. The burner type and size are etched into the plate/pan next to the knockout for that burner’s pilot assembly location. To install the pilot assembly:

LOCATE AND REMOVE THE APPROPRIATE KNOCKOUT

  1. Confirm the type and size of your burner on the Packing Slip for your Order.
  2. Locate the Pilot Assembly knockout on the plate/pan that matches your burner type and size. {See Photo 1}
  3. Remove the matching knockout by placing a screwdriver or other small tool in the opening at the edge of the knockout. Push one side of the knockout down to break the connector and remove the circular piece of aluminum with pliers. Do not remove any other knockouts. {See Photo 2}

INSTALLING THE PILOT ASSEMBLY ON THE PLATE/PAN

  1. Locate the Pilot Assembly. The Pilot Assembly consists of a wind cage, pilot burner, and self-tapping screws.
    • On the pilot assembly, you will see a hot surface igniter, a pilot burner, and a thermopile. {See Photo 3a and 3b}
  2. Remove the wind cage cap from the top of the pilot assembly and set it aside until the plate/pan is installed onto your fire feature.
  3. Carefully, unroll the wires coming from the bottom of the pilot. Feed the wires through the knockout opening created in step 1.3.
  4. Rotate the pilot assembly in the knockout opening until the circular opening on the wind cage and thermopile are adjacent to the nearest jet with the thermopile nearest to the jet. Position the pilot assembly to cover the entire knockout opening. {See Photo 4a and 4b}
  5. Once the wind cage is properly aligned, use the self-tapping screws to secure the wind cage to the plate or pan. {See Photo 5)

INSTALLING THE VALVE INTO THE PLATE/PAN

Warming Trends has two different drip legs for the Platinum Ignition System depending on the BTU supply of the burner. The first drip leg is for burners up to 299K BTUs and is made out of ½’’ piping. {See Photo 6} The second drip leg is for burners with 300K BTUs or more and is made out of ¾’’ piping.

  1. Identify the coupling under the plate and choose the correct drip leg. Apply joint compound, thread sealant, or plumbing tape to the threads of the exposed end of the provided 5” nipple on the drip leg assembly and tighten to the female end of the coupling with a wrench to avoid leaks. Align the tee so it is facing away and perpendicular to the two small holes cut out on the plate. {See Photo 7}
  2. Identify the gas outlet on the valve box assembly. The outlet should have a ½’’ x 2’’ nipple with a ½’’ x ¾’’ Reducing Bushing attached for units under 299K BTUs {See Photo 8a} or a ¾’’ x 3’’ nipple attached for units over 300K BTUs {See Photo 8b}
  3. Apply joint compound, thread sealant, or plumbing tape to the threads of the exposed end of the nipple on the valve and tighten to the female end of the tee on the drip leg. Tighten with a wrench to avoid leaks. {See Photo 9} Orient the valve so that the connectors on it face away from the plate. {See Photo 10}

CONNECTING THE PILOT TO THE VALVE ASSEMBLY

  1. Identify the connectors ports on the valve. One is black and labeled Hot Surface Igniter and one is gray and labeled Thermopile. Locate the connectors of the same color on the pilot assembly and plug them in to the matching connectors. {See Photo 11}
  2. Identify the brass male thread on the valve. Locate the corresponding brass female thread on the metal pilot tube extending from the wind cage. Join the female end on the pilot assembly to the male end on the valve using a ½’’ wrench (DO NOT APPLY ANY THREAD SEALANT). {See Photo 12}

CONNECTING THE TRANSFORMER TO THE VALVE ASSEMBLY

  1. Identify the transformer unit attached to an aluminum mounting bracket. The transformer unit also comes with two screws, two nuts, and two lock washers. There are two pre-cut holes on the plate. Line the holes on the bracket up with the holes on the plate and fasten the two together with the screws provided. Ensure the transformer unit is facing away from the center of the plate. {See Photo 13}
  2. Locate the two Phillips head screws on the transformer box that hold the panel in place. Unfasten these screws and remove the panel. {See Photo 14}
  3. On the bottom of the transformer unit, there are two large gray strain reliefs. One has a pigtail coming out of it to connect to the power supply and the other is empty. {See Photo 15} Loosen the empty strain relief and remove the cap.
  4. On the valve assembly, there is a blue and yellow wire sleeved together with connectors on the ends. Feed this through the uncapped strain relief on the transformer unit and tighten the strain relief back down around the wires. {See Photos 16a and 16b}
  5. Inside of the transformer unit, there is a blue and yellow wire with connectors on the ends. Connect these to the corresponding blue and yellow wires that were fed from the valve into the unit. {See Photo 17}
  6. Once the wires are connected, re-attach the panel on to the transformer unit.

ASSEMBLY FLEX LINE KITS FOR IGNITION

  1. Identify your FK1 flex line kit for units up to 299K BTUs. {See Photo 18}
  2. Identify the flared fitting that comes on the end of your flex line. There should be two total. Unscrew the flared fitting from the flex line, then apply thread sealant to the non-flared end of the fitting {See Photo 19} and screw into the “IN” side of the valve. Tighten with a wrench to avoid leaks. {See Photo 20}
  3. Screw the flex line onto the flared end of the flared fitting that is attached to the valve. Do not use thread sealant. Tighten with a wrench to avoid leaks. {See Photo 21}
  4. Apply thread sealant to the non-flared end of the second flared fitting and screw into one side of the provided key valve using thread sealant. Tighten with a wrench to avoid leaks. {See Photo 22}
  5. Mount the key valve and escutcheon plate to your fire pit, and then take the other end of the flex line and screw it into the flared end of the flared fitting on the key valve, connecting the key valve to the Platinum Valve. Do not use thread sealant. Tighten with a wrench to avoid leaks. {See Photo 23} The other end of the key valve will then connect to your gas supply.
    • FK2 Installation:
  6. Identify your FK2 for 300K BTU and above units. {See Photo 24}
  7. Identify one of the 3/4” x 3” nipples that comes with your kit. Apply thread sealant to one end of the nipple and screw into the “IN” side of the valve. Tighten leaks {See Photo 25}
  8. Your FK2 kit should have two flex lines. Each flex line comes with two flared fittings screwed onto the end. Remove these from the flex line. Identify the 3/4” tee that comes with your kit. Screw this onto the end of the 3/4” x 3” nipple attached to the valve. Then, screw the non-flared ends of two of the flared fittings into the tee. Use thread sealant for all connections and tighten all connections with a wrench to avoid leaks. {See Photo 26} for complete installation.
  9. Take the ends of your two flex lines and screw them into the flared ends of the two flared fittings seen in Photo 26. Do not use thread sealant. Tighten with a wrench to avoid leaks. {See Photo 27}
  10. Identify your other tee, nipple, remaining two flared fittings, and 3/4” key valve that come with the kit. Using thread sealant for all joints, assemble these components. Tighten with a wrench to avoid leaks. {See Photo 28}
  11. Mount the key valve assembly from 6.10 as well as the provided escutcheon plate to your fire pit. Then, take the two open ends of the flex lines from 6.9 and connect them to the flared fittings on the tee attached to your key valve assembly. This will connect the Key Valve to the Platinum Valve {See Photo 29}. The other end of the key valve will then connect to your gas supply. Do not use thread sealant. Tighten with a wrench to avoid leaks.

FINISHING UP

  1. Once all connections have been completed, place the burner system in the fire feature. Put the wind cage cap back on the wind cage. This must be done before any media is added to the feature to prevent any pieces from falling into the wind cage. Make sure the power to the feature is turned off. Plug the 6’ pigtail into the GFCI outlet. Turn the power on to ignite.

WARNING LABEL

The following label has been provided with the appliance. Affix the label in a conspicuous location adjacent to the appliance.

WARNING

  • Improper installation, adjustment alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Refer to the owner’s user guide provided with this appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
  • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances.
  • An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

MEDIA INSTALLATION

  • Only use approved decorative media (glass, lava rock, ceramic log sets, steel log sets, etc.) that have been manufactured for specific use in outdoor fire features.
  • Media must be ½” or larger in size to prevent media from falling into gas orifices and blocking flow of gas out of orifices. Use approved media only. To avoid media dust or debris from getting into the system, do not dump the media over the burner. Place the media onto the plate or pan.
  • Media should be piled no more than halfway up the pilot of assembly so that pilot gas orifice opening and the pilot cooling holes are above the media allowing for pilot flame to easily reach gas jet orifice. Incorrect media installation that blocks pilot cooling holes will cause the pilot flame to stifle, blocking of thermal sensor, and/or a delay in burner ignition. (See pictures below for examples of proper installation heights.)
  • For Ceramic Log Sets: Place logs on top of lava rock or media base according to preference and desired flame pattern. Do not block, cover, or obstruct the pilot assembly. Blocking, covering, or placing ceramic logs too close to the pilot assembly may cause excessive heat on pilot causing system to fail. Not covered under warranty.

OPERATION INSTRUCTIONS

WARNING: Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

WARNING: HOT – DO NOT TOUCH – SEVERE BURNS MAY RESULT – CLOTHING IGNITION MAY RESULT CAREFULLY SUPERVISE children in same area as the appliance. Alert children and adults to hazards of high temperature. Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance.

WARNING: The appliance should be inspected before use and at least annually by a qualified service technician. Any guard or protective device removed for servicing must be replaced prior to operation. Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

LIGHTING INSTRUCTIONS: ELECTRONIC IGNITION SYSTEMS

TURNING ON YOUR ELECTRONIC IGNITION SYSTEMS

  1. STOP! Read all the safety information and warnings in the Installation Manual before attempting to light fire feature.
  2. Any cover must be removed prior to operation of burner and must remain off during operation.
    • Danger: Fire or Explosion Hazard. If you smell gas, shut off gas to the appliance, extinguish any open flame. If odor continues, leave the area immediately. After leaving the area, call your gas supplier or fire department. Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.
  3. Confirm that your Natural Gas or Liquid Propane supply to the appliance is open or on.
  4. Before lighting, visually inspect fire feature and remove any accumulated leaves or other combustible debris.
  5. Turn on power to the fire feature with switch, button, or remote. Within 10 seconds of power application Pilot Flame should be lit and visible. Once the pilot is lit, the main burner will ignite shortly after.
  6. Use key valve to adjust flame to desired height.

_ WARNING: _A qualified, licensed electrician must install power supply. An outdoor NEMA rated GFCI Receptacle outlet should be installed within the interior of the enclosure above grade to supply power to system.

TURNING OFF YOUR ELECTRONIC IGNITION SYSTEMS

  1. Turn off power to fire feature –with remote control or wall switch.
  2. Turn key valve to OFF position by turning key to the right.
  3. If using LP bottle/tank – turn bottle/tank to CLOSED position.
  4. Verify flame is OUT.
  5. After allowing for ample cooling time, cover the fire feature with waterproof/weatherproof cover.

WARNING

  • For electronic ignition systems, which have an extended or detached valve box, the area in which the valve box is installed must conform with all installation requirements, including, but not limited to location, construction, venting, and local codes. Failure to do so may result in property damage, personal injury, or death.
  • If fire feature fails to turn off completely (small flames still visible) turn of gas supply using the manual gas shutoff.

GENERAL MAINTENANCE

WARNING

  • Installation and repair should be done by a qualified technician. Appliances should be inspected prior to each use and inspected at least once annually by a qualified gas appliance service professional.
  • Ensure gas and power are shut off and appliance is cool before servicing.
  • Any guard or protective device removed for servicing must be replaced prior to operating the appliance.

PRIOR TO EACH USE

  • Keep any debris out of appliance – clean as needed. If debris is found, remove before lighting system.

SEMI ANNUALLY

  • Every six months or as needed, remove media, lava rock, or glass from around the pilot assembly. Clean the thermocouple of any soot using soft brush. Be careful not to damage the igniter element. Be sure when returning your media to the feature to avoid over covering the jets and the pilot assembly as mentioned on page 8.
  • Once pilot assembly is clean, inspect to see flame that covers 3/8” to 1/2” of the thermocouple. Cleaning of pilot gas orifice may be required by removing pilot burner and orifice and cleaning out orifices from debris, soot, or anything that may be preventing gas flow from exiting the pilot gas orifice.

ANNUALLY

  • Annual inspection and cleaning of the fire feature is recommended. If at any time the flames exhibit any abnormal shapes or behavior or if burner fails to ignite properly, the holes located in the base of the gas jet orifices may require cleaning. To clean the appliance, carefully remove the logs and media to allow access to burner. Use a brush to carefully remove dust, spider webs, and loose particles. Periodical inspection by a qualified service technician of the air-intake on the side of the jet is recommended to ensure your fire feature performs properly.
  • If a jet is clogged, use a wire or small puncture tool and carefully insert in jet. Tool should be the size of a small paper clip.

WARNING

  • Fire feature should be inspected by user prior to each use and inspected at least once annually by a qualified gas appliance service professional.

TROUBLESHOOTING

Error codes are displayed by a flashing LED. This LED’s primary function is to aid a trained technician in diagnosing basic issues with the device. The repetition period of the flashes is 10 seconds, each flash is ON for 0.5 seconds and OFF for 0.5 seconds.

NUMBER OF FLASHES ERROR REASON
Solid LED No issue, Pit is ON and operational
LED Off No issue, Pit is OFF
1 HSI issue detected – HSI did not prove, likely needs to be replaced.
2 Thermopile issue detected – Thermopile did not detect heating or did not

get hot/

stay hot, likely needs to be replaced or pilot assembly has been damaged.

3| 24 hour timer trigger – Pit has been on for more than the maximum allowed time. Power cycle is required.
4| Hardware issues detected, please contact customer service.

TROUBLESHOOTING COUNTERMEASURES

Below are some potential causes and countermeasures to the symptoms.

NO PILOT FLAME. HSI HEATS UP BUT PILOT WON’T LIGHT

  • Air in the gas line – If this is a new install, it may take several attempts to purge the air.
  • Debris is in the gas line – Clear the gas line.
  • Water/Moisture is in the gas line – Clear the gas line.
  • Incorrect Gas pressure – Confirm proper gas pressure.
  • Pilot gas orifice is dirty – Remove the pilot head and clean.
  • Wind conditions might be too severe.

PILOT LIGHTS BUT BURNER WILL NOT LIGHT

  • Gas pressure is incorrect – Confirm proper gas pressure.
  • Small pilot flame – Remove the pilot head and clean pilot gas orifice.
  • Dirty thermal sensor – Clean using soft brush.
  • Debris is blocking gas orifice in burner – Purge water and air from gas lines or in the burner, and confirm there is no debris in gas lines.

BURNER TURNING OFF UNEXPECTEDLY

  • Improperly applied media – Make sure your media is not covering the pilot assembly and that your logs are not placed over or too near the wind cage.
  • Gas pressure is incorrect – Confirm proper gas pressure by checking at the gas stub to the feature and the Gas Inlet Pressure.
  • Wind conditions – Confirm the burner is properly located 4 – 6” inside the feature, and be sure the wind conditions are not too severe for safe use.

FIRE FEATURE IS MAKING A WHISTLING SOUND

  • Flex line issue – Confirm the correct size flex line is installed and there are no kinks or tight bends in the line.
  • Gas pressure is incorrect – If the whistling is coming from the jets, confirm the gas pressure is within the ranges recommended on the Gas Pressure Inlet chart provided on page 6. Adjust as needed.

Please contact your retailer or certified technician for service and repair if these suggestions do not solve the issue. If replacement parts are required – contact your retailer or licensed technician for authorized replacement parts. Warranty is null and void if unauthorized parts are used.

WARRANTY

PLATINUM IGNITION SYSTEM WARRANTY

ALL BURNERS AND ELECTRONICS MUST BE COVERED WHEN NOT IN USE OR WARRANTY IS NULL AND VOID

  • For Residential Installations, Platinum Ignition systems are fully-warranted for three (3) years from date of purchase. In the event a system must be replaced due to a defect/malfunction of the system, Warming Trends will repair or replace the system at no cost for the first three years. This warranty does not cover labor costs.
  • For Commercial Installations, Platinum Ignition systems are fully-warranted for one (1) year from date of purchase. In the event a system must be replaced due to a defect/malfunction of the system, Warming Trends will repair or replace the system at no cost for the first year. This warranty does not cover labor costs.
  • For all Platinum Ignition Systems, problems or defects in the functioning of the systems due to gas plumbing or electrical installed by others are not covered by any warranty offered by Warming Trends. No dealer, distributor, or other person has the authority to represent or warrant a
  • Warming Trends product beyond the terms contained within this warranty, and Warming
  • Trends assumes no liability for such warranty representations. Any questions concerning this warranty should be directed to the Warming Trends corporate office or via email: legal@Warming-Trends.com.
  • While some of our warranties are passed-through or provided in cooperation with third-parties, Warming Trends will honor the warranties for all products purchased from us, regardless of the manufacturer but we may coordinate internally with the necessary third-parties in order to do so.

YOUR RIGHTS UNDER STATE LAW

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. You may find this information from the Federal Trade Commission helpful in understanding your rights, but we recommend you speak to your attorney regarding your specific situation and the laws in your state or jurisdiction. https://www.consumer.ftc.gov/articles/0252-warranties

PROP 65 WARNING

WHAT IS “PROP 65”?

  • Proposition 65 (“Prop 65”) is a California law which requires businesses to provide warnings to Californians about significant exposures to chemicals that cause cancer, birth defects or other reproductive harm. These chemicals can be in the products that Californians purchase, in their homes or workplaces, or that are released into the environment. Prop 65 enables Californians to make informed decisions about their exposures to these chemicals.
  • Prop 65 also prohibits California businesses from knowingly discharging significant amounts of listed chemicals into sources of drinking water.
  • Prop 65 requires California to publish a list of chemicals known to cause cancer, birth defects or other reproductive harm.
  • This list, which must be updated at least once a year, has grown to include approximately 900 chemicals since it was first published in 1987.
  • Prop 65 became law in November 1986, and is also known as the Safe Drinking Water and Toxic Enforcement Act of 1986. Prop 65 does not apply to products sold outside of the state of California. For more info on Prop 65, go to: www.p65warnings.ca.gov. For a fully updated list of all the chemicals and compounds that are known to the State of California to cause cancer or reproductive toxicity, go to: https://oehha.ca.gov/proposition-65/proposition-65-list.

WARNINGS

  • Lead: Can cause birth defects or other reproductive harm. Lead can be found in brass fittings. View the fact sheet at www.p65warnings.ca.gov
  • Carbon Monoxide: Carbon monoxide is a colorless, odorless, and poisonous gas. It is formed during the combustion of various fuels. View the fact sheet at www.p65warnings.ca.gov
  • Bisphenol A: BPA is a widely used chemical that be found in linings, plastics, and other materials. It can cause harm to the female reproductive system. View the fact sheet at www.p65warnings.ca.gov
  • Furniture Product Exposure: Some furniture products can expose you to chemicals which are known to the State of California to cause cancer or birth defects or other reproductive harm. View the fact sheet at www.p65warnings.ca.gov
  • Want to see more? View all of the Prop 65 fact sheets at www.p65warnings.ca.gov

MORE INFO ON PROP 65

Note: The information provided is for informational purposes only and does not constitute legal advice. If you have any concerns about Prop 65 or how it may apply to our products, please consult your attorney.

HOW TO ORDER REPLACEMENT PARTS

  • Replacement parts are available for purchase. Please work directly with the dealer where you purchased your Warming Trends product(s) to order parts. If you are having issues working with the original point of purchase, please contact us and we will be happy to assist you.
  • Please reach out to us with any questions at Orders@Warming-Trends.com or call us at 303-346-2224.

103063NG

|

Platinum 24 Volt Electronic Ignition System – High Capacity Hot Surface Igniter + 24V Transformer + for 1/2″ Manifolds + Maximum Gas Output 680K BTU/hr – Natural Gas

|

$1939

---|---|---

103064LP

|

Platinum 24 Volt Electronic Ignition System – High Capacity Hot Surface Igniter + 24V Transformer + for 1/2″ Manifolds + Maximum Gas Output 680K BTU/hr – Liquid Propane

103065NG

|

Platinum 24 Volt Electronic Ignition System – High Capacity Hot Surface Igniter + 24V Transformer + for 3/4″ Manifolds + Maximum Gas Output 680K BTU/hr – Natural Gas

103066LP

|

Platinum 24 Volt Electronic Ignition System – High Capacity Hot Surface Igniter + 24V Transformer + for 3/4″ Manifolds + Maximum Gas Output 680K BTU/hr – Liquid Propane

CONTACT US

Whatever your question, our team is happy to help

Scan

Congratulations on your purchase!

  • We appreciate your business and look forward to seeing your finished project.
  • Tag us on Instagram! @WarmingTrends

SCAN TO VIEW OUR INSTAGRAM

Documents / Resources

| WARMING TRENDS Platinum Ignition 24 Volt Platinum Electronic Ignition Double [pdf] User Guide
Platinum Ignition 24 Volt Platinum Electronic Ignition Double, Platinum Ignition, 24 Volt Platinum Electronic Ignition Double, Electronic Ignition Double, Ignition Double, Double
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals