HYDRO Sprite TL Push Button Mode User Guide
- June 13, 2024
- HYDRO
Table of Contents
- Get into Programming Menu
- Prime the Pumps and Operation Mode
- Clear Load Count and Operation Mode choice
- Program Dispenser Lock Out Period
- Program Pump Run Time
- Program Pump Delay Time
- Program Additional Formulas
- If using washing machine signals, Program Filter Duration time
- Program User Prime Pumps
- Program Change Password
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Quick Start Guide
Sprite TL
Push Button Mode
Note: The following instructions will serve as a start-up programming base for the installation of a Sprite TL in Push Button Mode.
Get into Programming Menu
- To enter the programming menu press and hold the key for 2 seconds.
- The display will show 000 with the left 0 flashing.
- Press the key to change the digit to a 1.
- Press the key to advance to the middle digit.
- Press the key 2 times to change the digit to a 2.
- Press the key to advance to the right digit
- Press the key 3 times to change the digit to a 3.
- With the display showing 123 press the key.
Prime the Pumps and Operation Mode
- The display will show P-1 with the 1 flashing. (pump 1)
- Press the key to prime pump 1, press again to stop.
- Press the key to select P-2 (pump 2).
- Press the key to prime pump 2, press again to stop.
Clear Load Count and Operation Mode choice
- Press the key to display “Clr”. The screen will toggle between the current load count and “Clr” .
- Press the key to clear the load count.
- Press the key to display “oP”. (operation mode) The screen will toggle between the current operation mode and “oP”.
- Press the key to adjust the operation mode. Choices are “Pb” for Push Button mode (select this choice), or “oc” for Occurrence mode, or “Au” for Automatic mode.
Program Dispenser Lock Out Period
- Press the key to set the “oP” & advance to “LP”.
- Press the key to display “LP”(Lockout Period).
- Press the & key to adjust the desired “LP”.
- Press the key to set the Lockout Period .
Program Pump Run Time
- Press the key to display F-1 with the 1 flashing.
- Press the key to select a Formula to program.
- Press the key when desired Formula is displayed.
- Press the key to start & stop Pump 1 run time.
- Press the key to select P 2 (Pump 2).
- Press the key to start & stop Pump 2 run time.
Program Pump Delay Time
- Press the key to display “d1” with the 1 flashing. (d1 = pump 1 delay time, d2 = pump 2 delay time).
- Press the key to select a pump to delay.
- Press the key to display delay time.
- Press the & key to adjust the desired delay time.
- Press the key to set the delay time.
Program Additional Formulas
- Press the key and to display “Fin”.
- Press the key to display F-1 with the 1 flashing.
- Press the key to select another Formula to prog. or,
- Press the key to display “Fd”.
If using washing machine signals, Program Filter Duration time
- Press the key to select a Filter Duration time.
- Press the & key to adjust the desired delay time.
- Press the key to set the “Fd”.
Program User Prime Pumps
- Press the key to display “Upr (user prime). The screen will toggle between the current setting and “Upr”.
- Press the key to toggle “OFF” or “ON”.
Program Change Password
- Press the key to display “Pin”.
- Press the key if you want to change the “Pin”.
- Press the & key to change the desired NEW “Pin”.
- Press the key to set the “Pin”.
- Press the key to display “End”.
- Press the key to exit Programming Menu.
Warranty
Limited Warranty
Seller warrants solely to Buyer the products will be free from defects in
material and workmanship under normal use and service for a period of one year
from the date of completion of manufacture. This limited warranty does not
apply to (a) hoses; (b) products that have a normal life shorter than one
year; or (c) failure in performance or damage caused by chemicals, abrasive
materials, corrosion, lightning, improper voltage supply, physical abuse,
mishandling or misapplication. In the event the products are altered or
repaired by Buyer without Seller’s prior written approval, all warranties will
be void. No other warranty, oral, expressed or implied, including any warranty
of merchantability or fitness for any particular purpose, is made for these
products, and all other warranties are hereby expressly excluded. Seller’s
sole obligation under this warranty will be, at Seller’s option, to repair or
replace F.O.B. Seller’s facility in Cincinnati, Ohio any Products found to be
other than as warranted.
Limitation of Liability
Seller’s warranty obligations and Buyer’s remedies are solely and exclusively
as stated herein. Seller shall have no other liability, direct or indirect, of
any kind, including liability for special, incidental, or consequential
damages or for any other claims for damage or loss resulting from any cause
whatsoever, whether based on negligence, strict liability, breach of contract
or breach of warranty.
Hydro Systems Company
3798 Round Bottom Road
Cincinnati, OH 45244 U.S.A.
Phone 513-271-88OO
Toll Free 8OO.543.7184
Fax 513-271-O16O
Webhydrosystemsco.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>