DOMETIC GP-ADV-LiFePO4-100 Advanced Lithium Battery User Guide
- June 13, 2024
- Dometic
Table of Contents
DOMETIC GP-ADV-LiFePO4-100 Advanced Lithium Battery
DESCRIPTION
no | description |
---|---|
1 | Positive Te |
2 | Negative Terminal |
3 | Power Button (LED) |
4 | RV-C 1 |
5 | RV-C 2 |
WARNINGS
Find tech tips, manuals and support at gopowersolar.com
SCAN FOR FULL MANUAL
INTERFACE DESCRIPTION
LED (POWER BUTTON) INDICATORS
LED | Battery Mode Definition |
---|---|
Solid light | Power on mode |
Blinking light | Sleep/Reserve mode |
OFF | Power off mode |
VARIOUS POWER MODES
Press button for more than 3 seconds and release. The battery will enter sleep
mode. The LED will blink. Power off mode should only be used for long term
storage or to reset the BMS. Use sleep mode to disable output power of
batteries.
MOBILE APP
Scan the QR code to download the Go Power! Connect App for use with the Sun
Cycle® Advanced Lithium Battery.
CAN PORT WIRING
Part Number | Function |
---|---|
GP-RVC-BCR-ADV LFP TERMINATOR | Battery End Cap Terminating Resistor |
GP-ADV-BC-400-ADV LFP INTER-BATT HARNESS, 400MM | 100Ah Battery Inter-Connect |
Cable
GP-RVC-BC -ADV LFP RV-C SYSTEM HARNESS| System Connection Cable
HOW TO USE
To prevent a surge current, perform a “pre-discharge” as outlined in the steps below.
- Step 1 – Ensure all batteries are in Power Off mode.
- Step 2 – Connect batteries following the series or parallel connection diagrams found at gopowersolar.com/advanced-lithium-wiring. The Battery Inter-Connect Cable must be installed for each battery pack followed by a Battery End Cap Terminating Resistor cable on the last battery.
- Step 3 – Ensure battery pack terminals are correctly installed and connected to the inverter system.
- Step 4 – Press the power button on one of the battery packs for 3 seconds to wake up all battery packs from Power Off mode. The LED indicator will turn on
NOTE : Batteries are in Power Off mode when unboxed. Press the Power button for 3 seconds to turn on. If it doesn’t turn on, you will need to charge the battery.
The batteries need to be configured before they can be used. Please see battery manual for instructions on battery configuration.
BATTERY SPECIFICATIONS
Technology | Lithium Iron Phosphate |
---|---|
Nominal Voltage | 12.8 V |
Fully Charged Voltage (FC) | 14.6V |
Fully Discharged Voltage (FD) | 9.2V |
Capacity (Ah) | 100Ah |
Recommended Discharge Current | 100A |
Battery Discharge Terminated Voltage | 9.2V |
Recommended Charge Voltage | 14.2V |
Maximum Charge Current | 100A |
Recommended Charge Current | 20A- Battery pack at o·c-5·c & 45·c-55°C |
50A – Battery pack at 5·c-15·c
100A – Battery pack at 15°C-45°C
Standard Charge Method
| 0.2( CC (constant current) charge to FC, then
CV (constant voltage FC) charge till charge current decline to :50.05(
Inner Resistance| :::::10mO
Certifications| UL2054, CE, UKCA, UN38.3
Operating Temperature
| Charge: 32°F(0°() to 131°F(55°()
Discharge: -4°F(-20°() to 131°F(55°()
Storage Temperature1
| 1 month > 113°F(45°() to 140°F(60°() – Max 80% RH
3 months > 77°F(25°() to 113°F(45°() – Max 80% RH
6 months > 68°F(20°() to 77°F(25°() – Max 80% RH
Humidity
| Operating: 5% to 90 % RH
Storage: 45% to 85% RH
BMS Leakage Current| 20uA in Shutdown Mode
Terminal| P+ / P-: M8
Dimensions (LxWxH)| 12.4in x 6.9in x 8.7in (313.9mm x 174.1mm x 221mm
Weight| 26.5lbs (12kg)
77°F (20°() ±5 is the recommended storage temperature at 60% State of Charge while being in Power Off mode.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>