DOMETIC GP-ADV-LiFePO4-100 Advanced Lithium Battery User Guide

June 13, 2024
Dometic

DOMETIC GP-ADV-LiFePO4-100 Advanced Lithium Battery

DESCRIPTION

DOMETIC-GP-ADV-LiFePO4-100-Advanced-Lithium-Battery-
fig-2

no description
1 Positive Te
2 Negative Terminal
3 Power Button (LED)
4 RV-C 1
5 RV-C 2

WARNINGS

Find tech tips, manuals and support at gopowersolar.com

SCAN FOR FULL MANUAL

INTERFACE DESCRIPTION

LED (POWER BUTTON) INDICATORSDOMETIC-GP-ADV-LiFePO4-100-Advanced-Lithium-
Battery-fig-4

LED Battery Mode Definition
Solid light Power on mode
Blinking light Sleep/Reserve mode
OFF Power off mode

VARIOUS POWER MODES
Press button for more than 3 seconds and release. The battery will enter sleep mode. The LED will blink. Power off mode should only be used for long term storage or to reset the BMS. Use sleep mode to disable output power of batteries.

DOMETIC-GP-ADV-LiFePO4-100-Advanced-Lithium-Battery-
fig-6

MOBILE APP
Scan the QR code to download the Go Power! Connect App for use with the Sun Cycle® Advanced Lithium Battery.

CAN PORT WIRING

DOMETIC-GP-ADV-LiFePO4-100-Advanced-Lithium-Battery-
fig-9

Part Number Function
GP-RVC-BCR-ADV LFP TERMINATOR Battery End Cap Terminating Resistor
GP-ADV-BC-400-ADV LFP INTER-BATT HARNESS, 400MM 100Ah Battery Inter-Connect

Cable
GP-RVC-BC -ADV LFP RV-C SYSTEM HARNESS| System Connection Cable

HOW TO USE

To prevent a surge current, perform a “pre-discharge” as outlined in the steps below.

  • Step 1 – Ensure all batteries are in Power Off mode.
  • Step 2 – Connect batteries following the series or parallel connection diagrams  found at gopowersolar.com/advanced-lithium-wiring. The Battery Inter-Connect Cable must be installed for each battery pack followed by a Battery End Cap Terminating Resistor cable on the last battery.
  • Step 3 – Ensure battery pack terminals are correctly installed and connected to the inverter system.
  • Step 4 – Press the power button on one of the battery packs for 3 seconds to wake up all battery packs from Power Off mode. The LED indicator will turn on
    NOTE : Batteries are in Power Off mode when unboxed. Press the Power button for 3 seconds to turn on. If it doesn’t turn on, you will need to charge the battery.
    The batteries need to be configured before they can be used. Please see battery manual for instructions on battery configuration.

BATTERY SPECIFICATIONS

Technology Lithium Iron Phosphate
Nominal Voltage 12.8 V
Fully Charged Voltage (FC) 14.6V
Fully Discharged Voltage (FD) 9.2V
Capacity (Ah) 100Ah
Recommended Discharge Current 100A
Battery Discharge Terminated Voltage 9.2V
Recommended Charge Voltage 14.2V
Maximum Charge Current 100A
Recommended Charge Current 20A- Battery pack at o·c-5·c & 45·c-55°C

50A – Battery pack at 5·c-15·c
100A – Battery pack at 15°C-45°C


Standard Charge Method

| 0.2( CC (constant current) charge to FC, then

CV (constant voltage FC) charge till charge current decline to :50.05(

Inner Resistance| :::::10mO
Certifications| UL2054, CE, UKCA, UN38.3


Operating Temperature

| Charge: 32°F(0°() to 131°F(55°()
Discharge: -4°F(-20°() to 131°F(55°()


Storage Temperature1

| 1 month > 113°F(45°() to 140°F(60°() – Max 80% RH
3 months > 77°F(25°() to 113°F(45°() – Max 80% RH
6 months > 68°F(20°() to 77°F(25°() – Max 80% RH


Humidity

| Operating: 5% to 90 % RH

Storage: 45% to 85% RH

BMS Leakage Current| 20uA in Shutdown Mode
Terminal| P+ / P-: M8
Dimensions (LxWxH)| 12.4in x 6.9in x 8.7in (313.9mm x 174.1mm x 221mm
Weight| 26.5lbs (12kg)

77°F (20°() ±5 is the recommended storage temperature at 60% State of Charge while being in Power Off mode.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals