Introduction

The RSE300 and RSE600 Thermal Imagers (the Product or Imager) are stationary, infrared imaging cameras for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development.

The Imager can stream live infrared and IR-Fusion technology video to a PC that has SmartView R&D software installed. SmartView R&D is a high- performance, professional software suite for quality analysis and reporting. The Imager also works with MATLAB and LabVIEW

Contact Fluke

Fluke Corporation operates worldwide. For local contact information, go to our website: www.fluke.com.
To register your product, or to view, print, or download the latest manual or manual supplement, go to our website.
+1-425-446-5500 fluke-info@fluke.com

Safety Information

General safety information is in the printed Safety Information document that ships with the Product and at www.fluke.com. More specific safety information is listed where applicable.

Specifications

Complete specifications are at www.fluke.com. Search for RSE300 or RSE600.

Product Familiarization

Features
Table 1 lists the features of the Product.
Product Familiarization
Product Familiarization

LED Indicator
Table 2 explains what the colors on the LED indicator means.
Table 2. LED Indicator Light Colors

Color Description Action

Blinking red

|

Not ready or not able to talk to the engine.

| Wait for the Product to warm up. OrConnect the RJ45 connector end of the Ethernet cable to the Ethernet switch and the M12 connector end to the Product.If the problem persists, see Contact Fluke.
Solid red| Over ambient temperature.| Move the Product to a cool location.
Blinking green| Flash memory update is in progress.| NA
Solid green| Ready, IP address is set, and Ethernet cable is connected.| Use the Product.
Blinking yellow| Booting| NA
Solid yellow| Wait, the operating system is loading.| NA
Solid blue| Shutter is closed| NA

Operation

The Imager and SmartView R&D need a stable network connection to work properly. Set up your network without interference from other systems. Do not connect the Imager to a Virtual Private Network (VPN). SmartView R&D is a data-intensive application. Use of other dataintensive applications (streaming audio or video) on the PC or the same network system can cause loss of data

Note All thermal imagers need sufficient warm-up time for accurate temperature measurements and best image quality. Fluke recommends a warm-up period of 60 minutes for optimal performance

To set up the Product:

  1. Attach the antenna.

  2. Stabilize the Product either on a flat surface or a tripod.

  3. Connect the M12 end of the ethernet cable to the M12 ethernet jack on the Product. See Figure 1.
    a. Fully insert the ethernet cable into the ethernet jack.
    b. Rotate the ring 180 º clockwise. Connect the M12 connector end of the ethernet cable to the Product.
    Figure 1. M12 Ethernet Cable Connection
    Cable Connection

  4. Connect the RJ45 connector end of the ethernet cable to the ethernet jack on the PC. Se Figure 2.

  5. Connect the AC plug of the M16 DC power cable (15 V dc) to a power outlet and the M16 connector to the Product.

  6. Wait for the Product to warm up and the LED indicator to show solid green.

  7. Remove the lens cover.

  8. Use SmartView R&D to focus the image
    Figure 2. Product Setup
    Product Familiarization

SmartView R&D Software

SmartView R&D desktop software provides the ability to stream, analyze, and export radiometric video as well as create professional reports.

SmartView R&D desktop software features:

  • Radiometric video streaming
  • Radiometric video or image creation
  • Image analysis tools
  • Data trending tools
  • Data exports
  • Custom report

For more information on how to download and install SmartView R&D Software, go to: https://www.fluke.com/en-us/support/software-downloads/software-for- fluke-infrared-cameras.

Accessories

Table 3 is a list of the accessories available for the Imager.
Table 3. Accessories|

Model Description PN
FLK-RSE-MB Mounting Base 4961344
FLK-0.75X-WIDE-LENS Wide-Angle Infrared Smart Lens 4961174
FLK-2X-LENS 2X Telephoto Infrared Smart Lens 4961163
FLK-4X-LENS 4X Telephoto Infrared Smart Lens 4961188
FLK-MACRO-LENS Macro Infrared Smart Lens 4961195

Optional Lenses

Use optional lenses for more applications of infrared inspection work. Figure 3 shows how to install a lens.

Figure 3. Optional Lens Installation

Product Setup
For more information about optional lenses, go to www.fluke.com and search with the description in Table 3.

Maintenance

Cleaning and lens care are the only maintenance required to the Product.

Clean the Case
Clean the case with a damp cloth and a weak soap solution. Do not use abrasives, isopropyl alcohol, or solvents to clean the case.
Lens Care
W Caution
To prevent damage to the infrared lens:

  • Carefully clean the infrared lens. The lens has a delicate anti-reflective coating.
  • Do not clean the lens too vigorously because this can damage the anti-reflective coating.

To clean the lens:

  1. Use a pressurized can of air or a dry nitrogen-ion gun, if available, to blow off the particulates from the lens surface.

  2. Soak a lint-free cloth in a commercial lens cleaning liquid that contains alcohol, ethyl alcohol, or isopropyl alcohol.
    Caution: To prevent damage to the case, do not get the alcohol on the case.

  3. Squeeze the cloth to remove excess liquid.

  4. Wipe the lens surface in one circular motion and discard the cloth.

  5. If needed, repeat with a new lint-free cloth.