Introduction
The RSE300 and RSE600 Thermal Imagers (the Product or Imager) are stationary, infrared imaging cameras for use in many applications. These applications include equipment troubleshooting, preventive and predictive maintenance, building diagnostics, and research and development.
The Imager can stream live infrared and IR-Fusion technology video to a PC that has SmartView R&D software installed. SmartView R&D is a high- performance, professional software suite for quality analysis and reporting. The Imager also works with MATLAB and LabVIEW
Contact Fluke
Fluke Corporation operates worldwide. For local contact information, go to our
website: www.fluke.com.
To register your product, or to view, print, or download the latest manual or
manual supplement, go to our website.
+1-425-446-5500 fluke-info@fluke.com
Safety Information
General safety information is in the printed Safety Information document that ships with the Product and at www.fluke.com. More specific safety information is listed where applicable.
Specifications
Complete specifications are at www.fluke.com. Search for RSE300 or RSE600.
Product Familiarization
Features
Table 1 lists the features of the Product.
LED Indicator
Table 2 explains what the colors on the LED indicator means.
Table 2. LED Indicator Light Colors
Color | Description | Action |
---|
Blinking red
|
Not ready or not able to talk to the engine.
| Wait for the Product to warm up. OrConnect the RJ45 connector end of the
Ethernet cable to the Ethernet switch and the M12 connector end to the
Product.If the problem persists, see Contact Fluke.
Solid red| Over ambient temperature.| Move the Product to a cool location.
Blinking green| Flash memory update is in progress.| NA
Solid green| Ready, IP address is set, and Ethernet cable is connected.| Use
the Product.
Blinking yellow| Booting| NA
Solid yellow| Wait, the operating system is loading.| NA
Solid blue| Shutter is closed| NA
Operation
The Imager and SmartView R&D need a stable network connection to work properly. Set up your network without interference from other systems. Do not connect the Imager to a Virtual Private Network (VPN). SmartView R&D is a data-intensive application. Use of other dataintensive applications (streaming audio or video) on the PC or the same network system can cause loss of data
Note All thermal imagers need sufficient warm-up time for accurate temperature measurements and best image quality. Fluke recommends a warm-up period of 60 minutes for optimal performance
To set up the Product:
-
Attach the antenna.
-
Stabilize the Product either on a flat surface or a tripod.
-
Connect the M12 end of the ethernet cable to the M12 ethernet jack on the Product. See Figure 1.
a. Fully insert the ethernet cable into the ethernet jack.
b. Rotate the ring 180 º clockwise. Connect the M12 connector end of the ethernet cable to the Product.
Figure 1. M12 Ethernet Cable Connection
-
Connect the RJ45 connector end of the ethernet cable to the ethernet jack on the PC. Se Figure 2.
-
Connect the AC plug of the M16 DC power cable (15 V dc) to a power outlet and the M16 connector to the Product.
-
Wait for the Product to warm up and the LED indicator to show solid green.
-
Remove the lens cover.
-
Use SmartView R&D to focus the image
Figure 2. Product Setup
SmartView R&D Software
SmartView R&D desktop software provides the ability to stream, analyze, and export radiometric video as well as create professional reports.
SmartView R&D desktop software features:
- Radiometric video streaming
- Radiometric video or image creation
- Image analysis tools
- Data trending tools
- Data exports
- Custom report
For more information on how to download and install SmartView R&D Software, go to: https://www.fluke.com/en-us/support/software-downloads/software-for- fluke-infrared-cameras.
Accessories
Table 3 is a list of the accessories available for the Imager.
Table 3. Accessories|
Model | Description | PN |
---|---|---|
FLK-RSE-MB | Mounting Base | 4961344 |
FLK-0.75X-WIDE-LENS | Wide-Angle Infrared Smart Lens | 4961174 |
FLK-2X-LENS | 2X Telephoto Infrared Smart Lens | 4961163 |
FLK-4X-LENS | 4X Telephoto Infrared Smart Lens | 4961188 |
FLK-MACRO-LENS | Macro Infrared Smart Lens | 4961195 |
Optional Lenses
Use optional lenses for more applications of infrared inspection work. Figure 3 shows how to install a lens.
Figure 3. Optional Lens Installation
For more information about optional lenses, go to
www.fluke.com and search with the description in
Table 3.
Maintenance
Cleaning and lens care are the only maintenance required to the Product.
Clean the Case
Clean the case with a damp cloth and a weak soap solution. Do not use
abrasives, isopropyl alcohol, or solvents to clean the case.
Lens Care
W Caution
To prevent damage to the infrared lens:
- Carefully clean the infrared lens. The lens has a delicate anti-reflective coating.
- Do not clean the lens too vigorously because this can damage the anti-reflective coating.
To clean the lens:
-
Use a pressurized can of air or a dry nitrogen-ion gun, if available, to blow off the particulates from the lens surface.
-
Soak a lint-free cloth in a commercial lens cleaning liquid that contains alcohol, ethyl alcohol, or isopropyl alcohol.
Caution: To prevent damage to the case, do not get the alcohol on the case. -
Squeeze the cloth to remove excess liquid.
-
Wipe the lens surface in one circular motion and discard the cloth.
-
If needed, repeat with a new lint-free cloth.