nVent HOFFMAN WS625118SS Watershed Freestanding Enclosure
WARNING
Enclosure is TOP−HEAVY
- Stabilize enclosure before opening doors.
- Follow guidelines in “Large Enclosure Handling Manual”.
- To get additional copies of the “Large Enclosure Handling Manual”, call 1−800−355−3560.
WARNING
To avoid electric shock, do not energize any circuits before all internal
and external electrical and mechanical clearances are checked to assure that
all assembled equipment functions safely and properly.
Maintenance / Cleaning
Notice:
- Use of enclosure shall comply with manufacturer’s specification.
- Cleaning instructions shall comply with the equipment manufacturer’s specifications.
- Maintenance procedures and schedules shall follow the equipment manufacturer’s specifications.
Hardware Kits
- Included with your Hoffman enclosure is a complete package of hardware for back panel installation. Also provided is all the necessary hardware for grounding the back panel and doors to the enclosure body.
- The proper installation procedures for grounding the doors, covers, and optional panels is included with the ground kits.
- Ground wires are available from Hoffman Enclosures. Consult the latest Hoffman Specifiers Guide.
NSF Certification
- To maintain NSF certification, there must be a minimum of six inches of clearance under the enclosure and the perimeter between theenclosure back and mounting surface must be sealed with silicon rubber sealant. Also, replace lifting eyes with hole seals (order separately).
Enclosure Alterations
Hoffman cannot assure the safety or effectiveness of any alterations or additions not made by Hoffman Enclosures Inc. However, the following information may be helpful. These instructions do not eliminate the need to consult with equipment manufacturers and to observe all regulatory agency procedures and safe practices to assure the proper electrical and mechanical function of Hoffman products in each particular application.
Mounting Instructions
- Wall−mounted enclosures have either an internal mounting means or external mounting feet. Proper fasteners must be used in all mounting holes to secure the enclosure to the wall.
- Floor−mounted enclosures have floor−stands (legs) which include mounting plates. Proper fasteners must be used in all mounting holes to securely anchor the enclosure to the floor.
Door Closing Adjustments
- Two door (floor mounted)
The overlapping doors are factory−fitted to meet evenly at the top and bottom. If the floor under the enclosure is not level, the doors will not close evenly. In this case, place metal shims under the corners of the enclosure. The enclosure should be bolted in place with the doors closed to prevent tipping when installing shims. Shims under the right front corner will raise the right door. Shims under the left front corner will raise the left door. It is important that the doors meet evenly to insure a proper seal against liquids and dust. Be sure all mounting bolts are tightened securely.
PANEL INSTALLATION
When the interior panel is being installed, it may be necessary to bend one or more mounting studs slightly to permit the panel to fit in place. Simply position the panel on the studs that line up properly and pry the other studs into position with a suitable screwdriver inserted through the panel holes.
PRINT POCKET
The print pocket on the door can be inverted or removed entirely.
REMOVING HINGE PINS FROM CONTINUOUS HINGES
This is a difficult operation requiring at least two people. This procedure is
best accomplished by using a small diameter punch to drive the hinge pin
toward the bottom of the enclosure. When the hinge pin protrudes about two
inches below the bottom hinge barrel, bend the end of the pin 180° so it is
shaped like the letter “J”. Use an electric or air powered vibrating hammer
fitted with a tool which has a hole in the end to fit over the hinge pin, and
drive the hinge pin out while opening and closing the door. To install the
hinge pin, straighten the pin and drive it in with the vibrating hammer while
opening and closing the door. Most hinge pins have one end chamfered, so be
sure to start the chamfered end first when installing the pin.
ACCESSORIES AND HARDWARE
- Hoffman cannot assure the safety or effectiveness of any alterations or additions not made in its plant.
- Lock kits and latch kits are available for field or factory installation on many types of Hoffman enclosures. Lock kits provide key−locking capabilities. Latch kits permit rapid access to enclosure interiors while retaining the oil tight and dust tight features.
- Louver plate kits provide ventilation in enclosures where internal heat is a problem.
- Floor−stand kits for converting wall-mounting enclosures to floor mounting are available for field or factory installation on single door NEMA 12 and
- NEMA 4 enclosures.
- Drip shield kits are available for field or factory installation on single-door and double-door NEMA 12 enclosures.
- Electrical interlocks provide a positive internal safety lockout on electrical enclosures while the enclosure contents are energized.
- Swing−out panel kits provide a means of mounting gauges, switches, pilot lights and other components near the front of the enclosure.
- Safety Lockouts protect personnel and equipment by enabling multiple padlocks to be installed on a de−energized switch.
- Window kits are available for many types of Hoffman enclosures.
- Corrosion inhibitors protect interior components of enclosures, wireway, consoles, etc. from corrosion. There are no coatings, oils, or greases to apply.
- Hole seals are used to seal extra conduit openings, pushbutton holes, cutouts, etc. against dust, dirt, oil, and water.
- Terminal kit assemblies provide an easy method to mount terminal blocks in many types of Hoffman enclosures.
- Folding Shelves can be used to support instruments and test equipment.
- Pedestals are used to provide floor mounting at a working height for small to medium size enclosures.
- Standoffs are used for cleaning access on back side of the enclosure.
- Mounting foot kit is used for external wall−mounting.
- Temperature Control options are available to provide an optimal environment for your controls. Options include louvers, filter fans, heat exchangers, air conditioners, and electric heaters.
- Data Pocket Kits offer a convenient place for documentation.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>