The 1075 Series Panel Mount GFCI is an industrial-grade Ground Fault Circuit Interrupter that is designed to withstand tough work site conditions. It is available in both manual and automatic power-up models. The GFCI is Class A rated with open neutral protection and features a NEMA 4X Faceplate.

The 1060 Series Multiple Outlet GFCI is housed in a polycarbonate, impact- resistant enclosure that retains its properties even under extreme environmental conditions. It comes with spring-loaded flip lids to protect the outlets from work site contaminants when not in use. The unit is equipped with extra hard usage #12/3 SOOW cable and meets OSHA construction site requirements. It has a fast response trip time of less than .025 seconds and is Class A rated with open neutral protection. The enclosure is tamper-proof and offers unmatched vibration resistance, making it ideal for OEM applications.

Product Usage Instructions

1075 Series Panel Mount GFCI:

  1. Mount the GFCI in a suitable location using the provided hole configuration (1075-AR or 1075-MR).
  2. Connect the power supply to the GFCI using the appropriate wiring.
  3. Ensure that the GFCI is properly grounded.
  4. To power up the GFCI manually, press the “POWER” button.
  5. To test the GFCI, press the “TEST” button. The GFCI should trip and cut off power.
  6. To reset the GFCI after a trip, press the “RESET” button.

1060 Series Multiple Outlet GFCI:

  1. Place the GFCI in a suitable location.
  2. Connect the power supply to the GFCI using the appropriate wiring.
  3. Ensure that the GFCI is properly grounded.
  4. When not in use, close the spring-loaded flip lids to protect the outlets from work site contaminants.
  5. To test the GFCI, press the “TEST” button. The GFCI should trip and cut off power.
  6. To reset the GFCI after a trip, press the “RESET” button.

Note : For both GFCI models, refer to the user manual for detailed installation and troubleshooting instructions. Visit ericson.com/panelmount- gfci for the 1075 Series and ericson.com /multi-gfci for the 1060 Series.

For further assistance, contact Ericson at 1.800.ERICSON or visit ericson.com/rfq for inquiries.

1075 Series Panel Mount GFCI

  • cULus listed for U.S. and Canada
  • Provides open neutral protection
  • Quick and easy field installation into temporary panels and work boxes
  • Compact & portable, this unit is easy to use, store and transport
  • Unique vibration resistant design
  • Works on 2-wire or 3-wire circuits
  • Meets OSHA construction site requirements
  • Fast response trip time; less than .025 seconds
  • Molded polycarbonate enclosure is corrosion and impact resistant and stands up to the toughest work site conditions
  • Manual and automatic power-up models available
  • Class A with open neutral protection

ERICSSON-1075-AR-GFCI-Panel-Mount-FIG- \(1\)

ERICSSON-1075-AR-GFCI-Panel-Mount-FIG- \(2\)

1060 Series Multiple Outlet GFCI

  • Polycarbonate, impact resistant enclosure retains its properties under the most extreme environmental conditions

  • Spring-loaded flip lids protect outlets from work site contaminants when not in use

  • Unit comes standard with extra hard usage #12/3 SOOW cable

  • Meets OSHA construction site requirements

  • Fast response trip time; less than .025 seconds

  • Class A with open neutral protection

  • Tamper proof enclosure

  • Unmatched vibration resistance ideal for OEM applications

  • Multiple NEMA configurations availableERICSSON-1075-AR-GFCI-Panel-Mount-FIG- \(3\)

  • ericson.com  1.800.ERICSON