HOBO RXW-TMB-xxx RXW Temperature Sensor User Guide
- June 12, 2024
- Hobo
Table of Contents
HOBO RXW-TMB-xxx RXW Temperature Sensor
Product Information
- The RXW Temperature Sensor (RXW-TMB-xxx) is a wireless sensor that is designed to measure temperature and transmit the data to a station for monitoring. It is compatible with RX2105, RX2106, and RX3000 stations.
- The sensor node has an LCD screen that displays important information such as network connection status and signal strength. It is powered by rechargeable batteries and also provides information about the battery level.
- The sensor node can be mounted on a wall or pole using the included bracket. It is recommended to use a solar radiation shield (RS3-B) for accurate temperature measurements.
- For complete specifications, mounting guidelines, and other details, please refer to the full product manual available at www.onsetcomp.com/resources/documentation/22243-rxw-tmb-manual.
Product Usage Instructions
- Before setting up the sensor node, make sure to follow the instructions in the station quick start guide for your specific station model.
- Keep the sensor node near the station while completing the setup process.
- Open the door of the sensor node and install the rechargeable batteries.
- Press and hold the button on the sensor node for 3 seconds.
- Watch the sensor node LCD screen while it joins the network:
- The signal strength icon blinks while searching for a network.
- Once a network is found, the icon stops blinking and the bars cycle from left to right.
- Press the Select button on the station to switch to the module with the manager (module 2 on RX2105 or RX2106 stations).
- The network connection icon blinks while the sensor node completes the registration process, which may take up to five minutes.
- Once the sensor node has finished joining the network, the network connection icon is no longer displayed and the channel count on the station LCD increases by two (one for temperature and one for the sensor node battery).
- Press the Search button on the station to start searching for sensor nodes.
- The magnifying glass icon on the station blinks while it is in search mode waiting for sensor nodes to join the network.
- Press the Search button on the station again to stop the search for sensor nodes.
- To mount the sensor node, follow these steps:
- Orient the bracket so that the text “TOP” is facing upwards.
- If installing on a wall, use the two long screws included in the package to screw the bracket to the wall using the holes on the mid-section of the bracket.
- If installing on a pole, slip a cable tie through each of the channels on the bracket and fasten them around the pole.
- Insert the bottom of the sensor node into the retaining clips on the bottom of the bracket, then press the top of the sensor node into the clips at the top of the bracket.
- Use the short screw included in the package to fasten the sensor node to the bracket.
- Close the sensor node and secure it with a padlock. Make sure that the node seal is clean from foreign debris.
- To monitor sensor node status and health, visit www.hobolink.com and refer to the HOBOlink Help for further details.
If you have any questions or need assistance, please contact Onset Computer Corporation at U.S. and International Sales: 1-508-759-9500 or visit www.onsetcomp.com/support/contact.
Adding a Sensor Node to the HOBOnet® Wireless Sensor Network
Important: Keep the sensor node near the station while completing these
steps.
If you are setting up a new station, follow the instructions in the station
quick start guide before setting up this sensor node (go to
www.onsetcomp.com/resources/documentation/24380-man-
rx2105-rx2106-qsg for RX2105 and RX2106 stations or
www.onsetcomp.com/resources/documentation/18254-man-qsg-
rx3000
for RX3000 stations).
INSTRUCTION
- Press the Select button on the station to switch to the module with the manager (module 2 on RX2105 or RX2106 stations).
- Press the Search button. The magnifying glass icon blinks while the station is in search mode waiting for sensor nodes to join the network.
- Open the door and install the rechargeable batteries. Press this button on the sensor node for 3 seconds.
- Watch the sensor node LCD while it joins the network:
- This signal strength icon blinks while searching for a network.
- Once a network is found, the icon stops blinking and the bars cycle from left to right.
- This network connection “x” icon blinks while the sensor node completes the registration process, which may take up to five minutes.
- Once the sensor node has finished joining the network, the “x” icon is no longer displayed and the channel count on the station LCD increases by two (one for temperature and one for the sensor node battery).
- Press the Search button on the station again to stop the search for sensor nodes.
- Go to www.hobolink.com to monitor sensor node status and health. See the HOBOlink Help for
Installing the Bracket and Sensor Node
- Orient the bracket so the text TOP is facing upwards.
- To install the bracket onto a wall, use the two long screws included in the package. Screw the bracket to a wall using the two holes on the mid-section of the bracket.
- To install the bracket onto a pole, slip a cable tie through each of the channels on the bracket and fasten the tie around the pole.
- Insert the bottom of the sensor node into the retaining clips on the bottom of the bracket then press the top of the sensor node into the clips at the top of the bracket.
- Use the short screw included in the package to fasten the sensor node to the bracket.
- Close the sensor node and use a padlock to keep it secure. Note: Ensure that the node seal is clean from foreign debris.
Mounting and Positioning the Sensor Node
- Position the sensor node towards the sun, making sure the solar panel is oriented so that it receives optimal sunlight throughout each season. It may be necessary to periodically adjust the sensor node position as the path of the sunlight changes throughout the year or if tree and leaf growth alters the amount of sunlight reaching the solar panel.
- Make sure the sensor node is mounted a minimum of 1.8 m (6 feet) from the ground or vegetation to help maximize distance and signal strength.
- Consider using plastic poles such as PVC to mount the sensor node as certain types of metal could decrease the signal strength.
- Place the sensor node so there is full line of sight with the next sensor node. Use a repeater if there is an obstruction between sensor nodes.
- There should not be more than five sensor nodes in any direction from a repeater or the manager. Data from sensor nodes travels or “hops” across the network and may not reach the station if the sensor node is more than five hops away.
Sensor Mounting Guidelines
- Mount the sensor so that at least 10 cm (4 in.) of the sensor cable is placed in the medium that is being measured. The temperature sensor is approximately 0.32 cm (0.126 inches) from the end of the stainless steel tip.
- If the sensor cable is left on the ground, use conduit to protect against animals, lawn mowers, exposure to chemicals, etc.
- If you are mounting the sensor in water, place the sensor cable on the side of the mounting post facing downstream to protect it from getting damaged by floating debris.
- A solar radiation shield is strongly recommended when measuring outdoor air temperatures in direct sunlight. Mount the sensor with the solar radiation shield (RS3-B) as shown.
For specifications, complete mounting guidelines, and other details about this sensor node, refer to the full product manual. Scan the code at left or go to: www.onsetcomp.com/resources/documentation/22243-rxw-tmb- manual
© 2019–2023 Onset Computer Corporation. All rights reserved. Onset, HOBO, HOBOlink, and HOBOnet are registered trademarks of Onset Computer Corporation. All other trademarks are the property of their respective companies. This product has been manufactured by Onset Computer Corporation and in compliance with Onset’s ISO 9001:2015 Quality Management System.
U.S. and International Sales:
1-508-759-9500
www.onsetcomp.com/support/contact
22235-E MAN-QSG-RXW-TMB
References
- HOBOlink
- Onset HOBO and InTemp Data Loggers
- RXW Temperature Sensor (RXW-TMB-xxx) Manual | Onset's HOBO and InTemp Data Loggers
- Technical Support | Onset's HOBO and InTemp Data Loggers
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>