SMARTEH LBT-1.DO1 Bluetooth Mesh Relay Output Module User Manual
- June 12, 2024
- SMARTEH
Table of Contents
USER MANUAL
Longo Bluetooth Products LBT-1.DO1
Bluetooth Mesh Relay output module
Version 2
LBT-1.DO1 Bluetooth Mesh Relay Output Module
STANDARDS AND PROVISIONS: Standards, recommendations, regulations and
provisions of the country in which the devices will operate, must be
considered while planning and setting up electrical devices. Work on 100 ..
240 V AC network is allowed for authorized personnel only.
DANGER WARNINGS: Devices or modules must be protected from moisture, dirt and
damage during transport, storing and operation.
WARRANTY CONDITIONS: For all modules LBT-1 – if no modifications are performed
upon and are correctly connected by authorized personnel – in consideration of
maximum allowed connecting power, warranty of 24 months is valid from the date
of sale to the end buyer, but not more than 36 months after delivery from
Smarteh. In case of claims within warranty time, which are based on material
malfunctions the producer offers free replacement. The method of return of
malfunctioned module, together with description, can be arranged with our
authorized representative. Warranty does not include damage due to transport
or because of unconsidered corresponding regulations of the country, where the
module is installed.
This device must be connected properly by the provided connection scheme in
this manual. Misconnections may result in device damage, fire or personal
injury.
Hazardous voltage in the device can cause electric shock and may result in
personal injury or death.
NEVER SERVICE THIS PRODUCT YOURSELF!
This device must not be installed in the systems critical for life (e.g.
medical devices, aircrafts, etc.).
If the device is used in a manner not specified by the manufacturer, the
degree of protection provided by the equipment may be impaired.
Waste electrical and electronic equipment (WEEE) must be collected separately!
LBT-1 devices are developed considering the following standards:
- EMC: EN 303 446-1
- LVD: EN 60669-2-1
Smarteh d.o.o. operates a policy of continuous development.
Therefore we reserve the right to make changes and improvements to any of the
products described in this manual without any prior notice.
MANUFACTURER:
SMARTEH d.o.o.
Poljubinj 114
5220 Tolmin
Slovenia
ABBREVIATIONS
LED | Light Emitted Diode |
---|---|
PLC | Programmable Logic Controller |
PC | Personal Computer |
Op Code | Message Option Code |
DESCRIPTION
LBT-1.DO1 Bluetooth Mesh relay output module is designed to be used as a relay
digital output module with RMS current and voltage measuring possibility. The
module can operate with a wide range of DC and AC voltages. It can be placed
inside the 60mm diameter flush mounting box and so it can be used for
switching On and Off the power supply voltage of standard electric wall
sockets. It also can be placed inside the lights, inside various electrical
equipment and devices to switch On and Off their power supply voltage.
Additional switch input is provided to have the possibility of manually
switching On and Off the module relay.
LBT-1.DO1 Bluetooth Mesh relay output module can also be connected close to
the light in the traditional electrical wiring 115/230 VAC for lightning.
Light connected to the LBT-1.DO1 relay can be switched on and off with
existing light switches. The module can detect power supply input voltage drop
when the switch is pressed. Wire bridge on the last switch before the
LBT-1.DO1 relay module should be wired as shown in Figure 4. While LBT-1.DO1
is a Bluetooth Mesh module the relay output can be also switched On and Off by
using Bluetooth Mesh communication. At the same time relay RMS current and
voltage can be sent over the Bluetooth Mesh communication.
LBT-1.DO1 Bluetooth Mesh relay output module can only operate with Smarteh
LBT-1.GWx Modbus RTU Bluetooth Mesh gateway connected to the same Bluetooth
Mesh network. LBT-1.GWx Modbus RTU gateway is connected to the main control
device as Smarteh LPC-3.GOT.012 7″ PLC based Touch panel, any other PLC or any
PC with Modbus RTU communication. Besides Smarteh Bluetooth Mesh devices,
other standard Bluetooth Mesh devices can be integrated into above mentioned
Bluetooth Mesh network. More than a hundred Bluetooth Mesh devices can be
provisioned and can operate in a single Bluetooth Mesh network.
FEATURES
Table 1: Technical data
Communication standard: Bluetooth Mesh is a low power wireless mesh protocol
and allows device to device communication and device to main control device
communication. Radio frequency: 2.4 GHz
Radio range for direct connection: < 30m, depending on application and
building.
By using Bluetooth Mesh topology, much bigger distances can be achieved.
Power supply: 11.5 .. 13.5 V DC or 90 .. 264 V AC, 50/60Hz
Ambient temperature: 0 .. 40 °C
Storage temperature: -20 .. 60 °C
Status indicators: red and green LED
Relay output with maximum resistive load current 4 A AC/DC
RMS current and voltage measurement, power consumption measurement
Power supply line switch digital input, operating with 90 .. 264 V AC power
supply voltage
Switch digital input
Mounting in flush mounting box
OPERATION
LBT-1.DO1 Bluetooth Mesh Relay output module can only operate with Smarteh LBT-1.GWx Modbus RTU Bluetooth Mesh gateway while provisioned to the same Bluetooth Mesh network.
4.1.Other relay output module functions
- Factory reset: This function will delete all Bluetooth Mesh network parameters stored on LBT-1.DO1 relay output module and will restore to the conditions of the initial programming, ready for provisioning. See Table 5 for more information.
4.2.Operation parameters
LBT-1.DO1 Bluetooth Mesh Relay output module accepts a set of operation codes
as specified in below tables 2 to 4.
LBT-1.DO1 Bluetooth Mesh relay output module is communicating with the main
control device as Smarteh LPC-3.GOT.012 or similar via Smarteh LBT-1.GWx
Modbus RTU Bluetooth Mesh gateway. All communication between the main control
device is performed by using Modbus RTU communication. Individual Bluetooth
Mesh node configuration data should be observed by using the network
provisioning tool.
Table 2: 4xxxx, Holding registers, Modbus RTU to Bluetooth Mesh gateway
Reg. | Name | Description | Raw → Engineering data |
---|---|---|---|
10 | Execute command | Execute command for Read and/or Write by toggling bit |
BitO toggle → Write Bit1 toggle → Read
11| Destination address’| Destination node address. Can be a unicast, group or
virtual address| 0 .. 65535 → 0 .. 65535
12| Element index| Sending node model element index| 0 .. 65535→ 0 .. 65535
13| Vendor ID| Vendor ID of the sending node model| 0 .. 65535 → 0 .. 65535
14| Model ID’| Model ID of the sending node model| 0 .. 65535 → 0 .. 65535
16| Virtual address index’| Index of the destination Label UUID| 0 .. 65535 →
0 .. 65535
17| Application key index*| The application key index used| 0 .. 65535 → 0 ..
65535
18| Option code”| Refer to the option code table| 0 .. 63 → 0 .. 63
19| Payload byte length”| Refer to the option code table| 1 .. 10 → 1 .. 10
bytes
20| Payload word[Or| Refer to the option code table| 0 .. 65535 → 0 .. 65535
21| Payload word[1]”| Refer to the option code table| 0 .. 65535 → 0 .. 65535
22| Payload word[2]”| Refer to the option code table| 0 .. 65535 → 0 .. 65535
23| Payload word[3]”| Refer to the option code table| 0 .. 65535 → 0 .. 65535
24| Payload word[4]”| Refer to the option code table| 0 .. 65535 → 0 .. 65535
- Observed from network provisioning tool
** User defined parameters, refer to the option code table
Table 3: 3xxxx, Input registers, Modbus RTU to Bluetooth Mesh gateway
Reg. | Name | Description | Raw → Engineering data |
---|---|---|---|
10 | Messages pending | Number of messages pending in receiving buffer | 1 .. 10 |
→ 1 .. 10
11| Destination address| Destination node address. Can be a unicast, group or
virtual address| 0 .. 65535 → 0 .. 65535
12| Element index| Sending node model element index| 0 .. 65535 → 0 .. 65535
13| Vendor ID| Vendor ID of the sending node model| 0 .. 65535 → 0 .. 65535
14| Model ID| Model ID of the sending node model| 0 .. 65535 →0 .. 65535
15| Source address| Unicast address of the node model which sent the message|
0 .. 65535 → 0 .. 65535
16| Virtual address index| Index of the destination Label UUID| 0 .. 65535 → 0
.. 65535
17| Application key index| The application key index used| 0 .. 65535 →0 ..
65535
18| Option code| Refer to the option code table| 0 .. 63 → 0 .. 63
19| Payload length| Refer to the option code table| 1 .. 10 → 1 .. 10 bytes
20| Payload word[0]| Refer to the option code table| 0 .. 65535 → 0 .. 65535
21| Payload word[1]| Refer to the option code table| 0 .. 65535 →0 .. 65535
22| Payload word[2]| Refer to the option code table| 0 .. 65535 → 0 .. 65535
23| Payload word[3]| Refer to the option code table| 0 .. 65535 → 0 .. 65535
24| Payload word[4]| Refer to the option code table| 0 .. 65535 → 0 .. 65535
Table 4: Relay output LBT-1.DO1 option codes
Option code | Name | Description | Raw → Engineering data |
---|---|---|---|
1 | FW version status | FUMY/Lire VOIVO:1state: | 0.. 65535 → 0.. 65535 |
2 | Operation mode set | Node opoomon mode selecuon | 0 → Not used |
1 → Not used
2 → Not used
3 → Not used
4 → Reset
5 → Factory reset
9| Wake up interval command| Command to set the time interval in which the
device wakes up and sends data about the current and voltage status| 0 ..
65535 → 0 .. 65535 s
10| Wake up interval status| Status of the time interval in which the device
wakes up and sends data about the current and voltage status| 0 .. 65535 → 0
.. 65535 s
18| Voltage status| Input voltage RMS value| 0 .. 65535 → 0 .. 6553.5 V
19| Current status| Load current RMS value| 0 .. 65535 → 0 .. 65.535 A
40| Digital out command| Relay output command| 0 → OFF
1 → ON
41| Digital out status| Relay output status| 0 → OFF
1 → ON
53| PS line switch enable command| Command for enabling the power supply line
switch input| 0 → Disable
I → Enable
54| PS line switch enable status| Enable status of the power supply line
switch input| 0 → Disabled
1 → Enabled
55| Switch SW enable command| Command for enabling the SW switch input| 0 →
Disable
1 → Enable
56| Switch SW enable status| Enable status of the SW switch input| 0 →
Disabled
1 → Enabled
INSTALLATION
5.1.Connection scheme
Figure 4: Example of connection scheme
Figure 5: LBT-1.DO1 module
Table 5: Inputs, Outputs and LEDs
K1.1 | N1 | Load output: neutral or negative |
---|---|---|
k1.2 | N | Power supply input: neutral or negative (-) |
k1.3 | SW | Switch input: line, 90 .. 264 V AC, 11.5 .. 30 V DC |
K1.4 | L1 | Load output: line or positive |
K1.5 | L | Power supply input: line or positive (+), |
90 .. 264 V AC or 11.5 .. 30 V DC
LED1:red| Error| 2x blink inside 5 s time period = network/friend lost
3x blink inside 5 s time period = unprovisioned node
LED2:green| Status| 1x blink = normal operation.
It’s also feedback for S1 reed contact, when activated with magnet.
S1| Reed contact| Mode setting contact
Inside 5 s time window, perform corresponding number of swipes in duration of
not less than 200 ms with permanent magnet close to the window sensor S1 reed
contact position. Following window sensor action or mode will be set:
Number of swipes Action
5.2.Mounting instructions
Figure 6: Housing dimensions
Dimensions in millimeters.
Figure 7: Mounting in flush mounting box
-
Switching Off the main power supply.
-
When you mount the module inside the flush mounting box first check, that the flush mounting box is depth enough.
If needed please use an additional spacer between the flush mounting box and the socket or contact the producer for additional information. -
Mount the module up to the provided place and wire the module according to the connection scheme in Figure 4. When you connect the module to the traditional electrical wiring for lighting please be sure, that you wired the bridge on the last switch before the LBT-1.DO5 module as shown in Figure 4.
-
Switching On the main power supply.
-
After a few seconds Green or Red LED starts to blink, please see the flowchart above for details.
-
If the module is not provisioned Red LED will blink 3x, the provisioning procedure has to be started. Contact the producer for more details*.
-
Once provisioning is finished, the module will continue with the normal mode of operation and this will be indicated as Green LED blinking once per 10 seconds.
Dismount in reverse order.
*NOTE: Smarteh Bluetooth Mesh products are added and connected to a
Bluetooth Mesh network by using standard provisioning and configuration mobile
apps tool such as nRF Mesh or similar.
Please contact producer for more detail information.
SYSTEM OPERATION
LBT-1.DO1 Bluetooth Mesh relay output module can switch power to the output
load based on power suplly voltage drop pulse, based on switch input voltage
change or based on Bluetooth Mash command.
6.1.Interference warning
Common sources of unwanted interference are devices that generate high
frequency signals. These are typically computers, audio and video systems,
electronic transformers, power supplies and various ballasts. The distance of
the LBT-1.DO1 relay output module to the above mentioned devices should be at
least 0.5 m or greater.
WARNING:
- In order to protect plants, systems, machines and network against cyber threats it is necessary to implement and continuously maintain up to date security concepts.
- You are responsible for preventing unauthorized access to your plants, systems, machines and networks and they are allowed to be connected to the Internet only, when security measures like firewalls, network segmentation, etc. are in place.
- We strongly recommend the updates and usage of the latest version. Usage of the version that is no longer supported may increase the possibility of cyber threats.
TECHNICAL SPECIFICATIONS
Table 7: Technical specifications
Power supply| 11.5 .. 13.5 V DC
90 .. 264 V AC, 50/60 Hz
---|---
Fuse| 4 A (T-slow), 250 V
Max. power consumption| 1.5 W
Load voltage| Same as power supply voltage
Maximum load current • (resistive load)| 4 A AC/DC
Connection type| Screw type connectors for stranded wire 0.75 to 2.5 mm2
RF communication interval| Minimum 0.5 s
Dimensions (L x W x H)| 53 x 38 x 25 mm
Weight| 50 g
Ambient temperature| 0 .. 40°C
Ambient humidity| Max. 95 %, no condensation
Maximum altitude| 2000 m
Mounting position| Any
Transport and storage temperature| -20 to 60 °C
Pollution degree| 2
Over voltage category| II
Electrical equipment| Class II (double insulation)
Protection class| IP 10
- NOTE: Special care must be taken in case of usage inductive character loads, e.g. contactors, solenoids, or loads that draw high inrush currents, e.g. capacitive character load, incandescent lamps. Inductive character loads cause over-voltage spikes at output relay contacts when they are switched off. The use of appropriate suppression circuits is advised. Loads that draw high inrush currents may cause the relay output to be temporarily overloaded with the current above its allowed limits, which may damage the output, even though that steady-state current is within the allowed limits. For that type of load, the use of an appropriate inrush current limiter is advised.
Inductive or capacitive loads influence the relay contacts by shortening their working life period or can even permanently melt contacts together. Consider using another type of digital output (e.g. triac).
MODULE LABELING
Figure 10: Label
Label (sample):
XXX-N.ZZZ.UUU
P/N: AAABBBCCDDDEEE
S/N: SSS-RR-YYXXXXXXXXX
D/C: WW/YY
Label description:
-
XXX-N.ZZZ – full product name,
• XXX-N – product family,
• ZZZ.UUU – product, -
P/N: AAABBBCCDDDEEE – part number,
• AAA – general code for product family,
• BBB – short product name,
• CCDDD – sequence code,
• CC – the year of code opening,
• DDD – derivation code,
• EEE – version code (reserved for future HW and/or SW firmware upgrades), -
S/N: SSS-RR-YYXXXXXXXXX – serial number,
• SSS – short product name,
• RR – user code (test procedure, e.g. Smarteh person xxx),
• YY – year,
• XXXXXXXXX – current stack number, -
D/C: WW/YY – date code,
• WW – week and,
• YY – the year of production.
Optional:
- MAC,
- Symbols,
- WAMP,
- Other.
CHANGES
The following table describes all the changes to the document.
Date | V. | Description |
---|---|---|
26.05.23 | 2 | Reviewed text, fuse and relay specifications. |
05.05.23 | 1 | The initial version, issued as LBT-1.DO1 relay output module User |
Manual.
NOTES
Written by SMARTEH d.o.o.
Copyright © 2023, SMARTEH d.o.o.
User Manual
Document Version: 2
May 2023
SMARTEH d.o.o. / Poljubinj 114 / 5220 Tolmin / Slovenia / Tel.: +386(0)5 388 44 00 / e-mail: info@smarteh.si / www.smarteh.si