CONTRIK CPT-C2-T6-CB Power Turtle Xtreme Outdoor Instruction Manual

June 12, 2024
CONTRIK

CONTRIK CPT-C2-T6-CB Power Turtle Xtreme Outdoor

Product Information
The Power Turtle Active is a reliable and safe product designed for various applications. It belongs to the CONTRIK CPT series and is part of the PGD-0023 product group. The product may have optical deviations from the illustrations in the manual due to different components and design variations. It is important to follow the operating instructions and any additional instructions included in the scope of delivery. The product should only be passed on to third parties in its original packaging or with this operating manual to ensure proper usage. It is essential to comply with national regulations, legal requirements, and provisions related to safety, accident prevention, occupational health, environmental regulations, and any other applicable regulations in the respective country. Please note that the product is not intended for use in the medical field or in explosive or flammable environments. The product should be used in accordance with the DGUV regulation 3 for mobile equipment in Germany. Any modification or change to the product is not allowed for safety and approval reasons (CE).

Product Usage Instructions

  1.  Check Delivery: Before using the product, carefully check the delivered package to ensure all components are present and in good condition. Refer to VDE 0701/0702 standards for further guidance on inspection.
  2. Safety Instructions: Read the operating instructions thoroughly and pay special attention to the safety instructions provided. Failure to follow these instructions may result in personal injury or property damage. Please note that not following the instructions may void the warranty/guarantee.
  3. Requirements for Installer and Operator: The operator is responsible for the proper use and safe operation of the product. If non-professionals are operating the product, the installer and operator must ensure that all requirements are met to maintain safety standards.
  4. Product Description – Unit Design and Variants:

The Power Turtle Active has different variants and is equipped with the following components:

  • A: CEE 5 Pol. 32 A Input
  • B: Phase control
  • C: Fuse protection 6 x MCB
  • D: CEE 5 Pol. 32 A output/through-hole

 Operating Instructions

Refer to the provided operating instructions for detailed steps on how to use the Power Turtle Active. The instructions will guide you through the proper setup, usage, and maintenance of the product.

Commissioning
Commissioning of the product should only be performed by a qualified electrician. It is important to ensure that the device is connected to a supply line with an appropriate cable cross-section and backup fuse to prevent fire hazards or device damage. Always refer to the information on the type plate and carefully check the connection of the sockets.

Power Turtle Xtreme

FEATUREDCONTRIK-CPT-C2-T6-CB-Power-Turtle-Xtreme-Outdoor-
FIG-1

General

The information in this manual applies exclusively to the devices described in this manual and all variants of the CONTRIK CPT series. Depending on the design of the devices and due to different components, there may be optical deviations with the illustrations in the manual. In addition, the devices may differ from each other functionally or in their operation. In addition to these operating instructions, other instructions (e.g. device components) may be included in the scope of delivery, which must be observed in full. In addition, improper use can cause hazards such as short circuits, fire, electric shock, etc. Only pass the product on to third parties in its original packaging or with this operating manual. For the safe use of the product, the national, legal regulations and provisions (e.g. accident prevention and occupational health and safety regulations as well as environmental regulations) of the respective country must also be observed. All company names and product designations contained herein are trademarks of their respective owners. All rights reserved. For safety and approval reasons (CE), you may not modify and/or change the product. The product is not intended for use in the medical field. The product is not intended for use in explosive or flammable environments. Please pay attention to the national regulations: For Germany, it is mobile equipment, and therefore the instructions of the DGUV regulation 3 have to be followed.

Check delivery

  • Power Turtle Xtreme
  • Electrical test report according to VDE 0701/0702

Safety instructions

Read the operating instructions carefully and observe the safety instructions in particular. If you do not follow the safety instructions and the information on proper handling in this operating manual, we will not accept any liability for any resulting personal injury/property damage. In addition, the warranty/guarantee will be voided in such cases. This symbol means: Read the operating instructions.

  • The product is not a toy. Keep it away from children and pets.
  • It voids the warranty, in case of manual modifications of the device.
  • Do not look into activated lamps. Possibly harmful to the eye.
  • Wearing safety gloves is recommended to avoid pinch injuries and burns at high ambient temperatures.
  • Protect the product from extreme temperatures, direct sunlight, strong vibrations, high humidity, strong water jets, falling objects, flammable gases, vapors and solvents.
  • Do not subject the product to very high mechanical stress.
  • If safe operation is no longer possible, take the product out of operation and protect it from unintended use. Safe operation is no longer guaranteed if the product:
  • shows visible damage,
  • no longer functions properly,
  • has been stored under unfavorable ambient conditions for an extended period of time, or
  • has been subjected to considerable transport stresses.
  • Handle the product with care. The product may be damaged by shocks, impacts or dropping.
  • Also, observe the safety instructions and operating instructions of the other devices that are connected to the product.
  • There are parts inside the product that are under high electrical voltage. Never remove covers. There are no user-serviceable parts inside the unit.
  • Residual current circuit breakers (FI and FI/LS) must be checked for their function by pressing the test button before each use and at least once a month. If the residual current circuit breaker does not trip, it must be checked or replaced immediately.
  • Use a properly insulated 5-pole CEE cable to connect the device to the 400 V mains. Do not make any changes to the CEE cable and the CEE plug devices. Failure to do so may result in an electric shock and pose a risk of fire or death. If you are unsure, contact an authorized electrical technician.
  • Never plug in or unplug power plugs with wet hands.
  • Only use a proper 5-pin CEE mains socket (400 V/AC, 50 Hz) approved by a qualified person as the power source.
  • When supplying power to the device, make sure that the cable cross-section of the connecting cable is sufficiently dimensioned according to national norms.
  • Never connect the product to the power supply immediately after it has been moved from a cold room to a warm room (e.g. during transport). The resulting condensation water can possibly destroy the device or lead to an electric shock!
  • Allow the product to come to room temperature first.
  • Wait until the condensation water has evaporated, this may take several hours. Only then may the product be connected to the power supply and put into operation.
  • Do not overload the product. Observe the connected load in the technical data.
  • Do not operate the product covered! At higher connected loads, the product heats up, which can lead to overheating and possibly fire when covered.
  •  The product is only de-energized when the mains plug is pulled out.
  •  Make sure that the product is de-energized before connecting a device to it.
  • The mains plug must be disconnected from the socket under the following conditions: before cleaning the product during thunderstorms when the product is not used for a long period of time.

Requirements for installer and operator

The operator is responsible for the proper use and safe operation of the manifold. When the manifold is operated by non-professionals, the installer and operator must ensure that the following requirements are met:

  • Ensure that the manual is permanently stored and available at the manifold.
  • Ensure that the layperson has read and understood the instructions.
  • Ensure that the layperson is instructed in the operation of the manifold before using it.
  • Ensure that the layperson only uses the distributor as intended.
  • Ensure that persons who cannot assess the dangers involved in handling the distributor (e.g. children or persons with disabilities) are protected. Ensure that a qualified electrician is consulted in the event of malfunctions.
  • Ensure that national accident prevention and work regulations are observed.

Operating instructions

  • Never pour out liquids on top of or next to the product. There is a high risk of fire or life-threatening electric shock. If liquid should nevertheless get inside the device, immediately switch off all poles of the CEE mains socket to which the product is connected (switch off fuse/automatic circuit breaker/FI circuit breaker of the associated circuit).

  • Only then disconnect the mains plug of the product from the mains socket and contact a qualified person. Do not operate the product any longer.

  • In commercial facilities, observe the local accident prevention regulations.
    For Germany:

  • German Federation of Institutions for Statutory Accident Insurance and Prevention (Verband der gewerb lichen Berufsgenossenschaften) for electrical systems and equipment. In schools, training centers, hobby and do-it-yourself workshops, the handling of electrical equipment must be supervised by trained personnel

  • Contact a specialist if you have any doubts about the operation, safety or connection of the product.

  • Have maintenance, adjustment, and repair work carried out exclusively by a specialist or a specialist workshop.

  • If you still have questions that are not answered in this operating manual, contact our technical customer service or other specialists.

Product Description Unit design and variants

Pos. Description
1 Article description
2 QR code for further options such as: Manual
3 Protection class (IP)
4 Rated voltage
5 Number of outer conductors
6 Input connector
7 Serial number (& batch number)
8 Product group
9 Mandatory self-declaration (WEEE Directive)
10 CE marking
11 Part number

Commissioning

The activities described in this chapter may only be carried out by a qualified electrician! If the device is connected to a supply line with an insufficient cable cross-section and/or insufficient backup fuse, there is
a risk of fire which can cause injuries or an overload which can cause damage to the device. Observe the information on the type plate! Check the connection of the sockets

  • Supply the power distributor with power via the connection.
  • Switch on the protective devices.

Operation

This device is used to distribute electric current to several connected consumers. The devices are used as power distributors indoors and outdoors as mobile distributors. The device is designed for professional use and is not suitable for use in households. Only use the device as described in these operating instructions. Any other use, as well as use under other operating conditions, is considered improper and may result in personal injury or property damage. No liability is accepted for damage resulting from improper use. The device may only be used by persons who have sufficient physical, sensory, and mental capabilities as well as appropriate knowledge and experience. Other persons may only use the device if they are supervised or instructed by a person responsible for their safety. Only distributors with a degree of protection that corresponds to the degree of protection required at the place of use may be used.

Protection against foreign bodies and weather influences

The power distributors comply with protection class IP 44 according to DIN EN 60529 (VDE 0470-1), provided that the position of use is observed.
IP 44 means in detail:

  •  IP 4X: Protected against solid foreign bodies with a diameter of 1.0 mm or more, e.g. a wire.
  • IP X4: Protection against splashing water from all sides.
  • Both during storage and operation, the cPot plug and input connector must be covered or plugged in to comply with IP 44.

Cleaning

  • The housing, mounting materials, and suspensions must not show any signs of deformation. Cleaning of the interior of the device may only be carried out by qualified personnel.
  • Please check the local regulations for the product inspection details. For Germany: According to DGUV regulation 3, this inspection must be carried out by a qualified electrician or an electrically instructed person using suitable measuring and testing equipment. A period of 1 year has proven to be the testing interval. You must determine the interval in accordance with DGUV Regulation 3 Implementation Instructions to suit your actual operating conditions. The range is between 3 months and 2 years (office).
  • Switch off the product before cleaning. Then disconnect the plug of the product from the main socket. Then disconnect the connected consumer from the product.
  • A dry, soft and clean cloth is sufficient for cleaning. Dust can be easily removed using a long-haired, soft and clean brush and a vacuum cleaner.
  • Never use aggressive cleaning agents or chemical solutions, as this may damage the housing or impair function.

Disposal
Electronic devices are recyclable materials and do not belong in household waste. Dispose of the product at the end of its service life in accordance with the applicable legal requirements. By doing so, you fulfill the legal obligations and make your contribution to environmental protection. Send the device to the manufacturer for disposal free of charge..

Technical data

Further technical data can be found in the corresponding data sheets or at www.contrik.com

General specifications

  • Supply voltage 415 V/AC, 50 Hz
  • Rated current 32 A Power Turtle Xtreme Outdoor
  • Output connections 32 A Power Turtle Xtreme Outdoor
  • Output connections powerCON
  • TRUE1: 250 V 16 A 32 A CEE flat socket 415 V
  • LINK looped through and not fused
  • Protection class IP65
  • Operating temperature -25 to +40°C
  • Operating temperatures > 20° C change the tripping behavior of the circuit breakers.
  • Relative 95 % at –5 °C to +30 °C
  • Humidity 70 % at +35 °C
  • Indoor: 57 % at +40 °C
  • Outdoor: 100 % at –25 °C to +27 °C
  • Dimensions approx. ca. 255 mm x 155 mm x 188 mm
Pos. Description
1 Article description
2 QR code for further options such as: Manual
3 Protection class (IP)
4 Rated voltage
5 Number of outer conductors
6 Input connector
7 Serial number (& batch number)
8 Product group
9 Mandatory self-declaration (WEEE Directive)
10 CE marking
11 Part number

Imprint
Subject to change due to technical progress! These operating instructions correspond to the state of the art at the time of product delivery and not to the current development status at Neutrik. If any pages or sections of these operating instructions are missing, please contact the manufacturer at the address given below.

This user manual is protected by copyright. No part or all of this user manual may be reproduced, duplicated, microfilmed, translated, or converted for storage and processing in computer equipment without the express written permission of Neutrik.Copyright by: Neutrik AG
Document Identification:
Document No.: BDA 684 V1
Version: 2023/02
Original Language: German

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals