Clean Ream Extreme®
Instructions
PPR75, PPR100, PPR125, PPR150, PPR200,
PPR250, PPR300, PPR400
ASSEMBLY
- Insert Shaft into Body.
- Make sure shaft is all the way through and flush with the bottom of the reamer.
- Using a 1/8” Allen wrench, tighten set screw.
NOTE: These reamers can be used with standard or cordless drills. For most
effective use, run the drill at a low or medium RPM. Do not use impact drills.
WARNING: 3” and 4” fitting reamers create a large reaction torque that
can cause injury to operator, therefore a standard 1/2” right angle drill is
recommended. Use caution when using these tools. For reaming 3” or 4”, a lower
RPM is recommended to reduce heat and possible distortion of the fitting.
INSTRUCTIONS
- Cut damaged pipe as close to fitting as possible.
- Select proper size fitting reamer, put it in drill chuck, and tighten.
- Insert fitting reamer into pipe, ensure tool stays on center to prevent binding. If no chips are being made, remove tool and check.
- Ream old pipe until proper depth is attained. Proper depth is when old pipe has been completely removed from fitting. Do not ream beyond end of the pipe or into the seat of the fitting. When close to end of ream, stop several times and remove reamer and visually check depth.
- Remove drill and clean out chips from fitting.
NOT recommended for high pressure supply systems or for vent side of gas burning appliance piping systems.
Parts
Parts List
¾” – 1” 1-¼” – 4”
Ref. No. | Description | Item Code | Item Code | Qty . |
---|---|---|---|---|
1 | SHAFT | 44525 | 44524 | 1 |
2 | CARBIDE INSERT | 24523 | 24524 | 1 |
3a | 8-32 CAP SCREW | — | 24525 | 1 |
3b | 4-40 CAP SCREW | 24522 | — | 1 |
4 | 1/4″ – 20 SET SCREW | 30087 | 30087 | 1 |
Rotate Carbide Insert: Carbide insert has four cutting edges. Change
cutting edge by removing the cap screw and rotating the carbide 180° then
reinsert cap screw and tighten. Replace carbide as needed.
0623-54521
See Also: RP-103
Reed Manufacturing
www.reedmfgco.com
Erie, PA USA
0623-54521
Documents / Resources
|
REEDY PPR100 Clean Ream
Extreme
[pdf] Instructions
PPR75, PPR100, PPR125, PPR150, PPR200, PPR250, PPR300, PPR400, 04521, 04522,
04523, 04524, 04525, 04526, 04527, 04528, 04532, PPR100 Clean Ream Extreme,
PPR100, Clean Ream Extreme, Ream Extreme, Extreme
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>