Instruction

Installation Precautions

Cautions

  • The wall for mounting the appliance shall be able to withstand at least fourfold of the total mass of the appliance when filled with water. Take reliable reinforcement measures when necessary.
  • Appliance should be installed as close as possible to frequent water points to reduce heat loss from pipelines.
  • Adequate space must be left around the appliance to facilitate future maintenance. When the appliance is installed above the ceiling, the ceiling shall be provided with a movable plate and a maintenance window for removing and installing the appliance.
  • Safety drainage measures such as floor drains must be in place to prevent leakage of appliances from causing damage to other facilities.
  • It must be installed indoors and where the temperature of the link is above 0°C,  so as not to cause ice to break the water pipe of the tank.
  • There should be no inflammable or explosive objects around the installation appliance.
  • Do not reverse connection of inlet and outlet water pipes. Sealing gaskets should be installed at the interface of inlet and outlet water pipes, and the rotating force should be appropriate during installation.
  • A safety valve (a pressure relief device) shall be installed at the inlet of the appliance through which water may flow out of the relief valve drain pipe. The outlet of the relief valve shall be maintained in contact with the atmosphere. The drain pipe should be securely fixed at the outlet of the relief valve.
  • The attachments provided by our company must be used.
  • Sockets providing power to appliances must be reliably grounded. Do not install power sockets in places that may be damp or wet.
  • The installation must be performed by professional installation personnel.

Packing List

Name Quantity Name
■ Water Heater 1 ■ Bracket
■ Manual 1 ■ Sealing Gasket
■ Safety Valve 1 ■ Plastic Expansion Tube
■ Water Drain Pipe 1
■ Fastening Screw 2

Installation

Methods of Installation

Equipment installation

  1. After the installation position of the appliance is determined, drill two holes with a spacing of 62mm and a diameter of ¢10mm in the horizontal direction of the wall according to the size as shown in the following figure, and the hole depth shall not be less than 90mm. Insert two plastic expansion tubes into the hole, and secure Ficha the host mounting plate with fastening screws.
  2. Align the two hanging holes on the back of the appliance with the two hooks of the hanging plate and pull down with force to make the hanging holes hang into the hook.
    Installation

Warning: The appliance must be hung securely to prevent personal injury and property damage from falling.

Tube Connection
The specification of inlet and outlet water interface of this appliance is GI/2. Saida entrada (azul) Connect pipes according to the following figure.

  1. Connect the gasketed safety valve attached to the inlet port of the appliance with the arrow pointing in the direction of flow.
  2. Insert the drain pipe into the bottom of the safety valve outlet, the other end of the continuous downward to the safe drainage (such as into the floor drain), the drain pipe should be unobstructed installation, and the safety valve outlet is connected with the atmosphere.
  3. When the water inlet pressure is more than 0.55 MPa, an additional safety valve should be added on the water inlet pipe.
    Tube Connection

Multiple Outlet Connection
If the user wants to implement a multi-pipe supply system, please refer to the method shown on the drawing for connection.
Instruction

Notice

  • The rated pressure of safety valve is 0.75MPa. When the pressure of the pipeline system exceeds its rated pressure, the safety valve will automatically drain and relieve pressure, and water flow out of the outlet is a normal phenomenon.
  • The drain pipe connected to the pressure relief device (safety valve) must be installed in a continuous downward direction in a frost-free environment. (Lead the other end continuously downward to a safe drain (such as into a floor drain) to prevent hot water from flowing out).
  • The blue is the water inlet, and the red is the water outiet.
  • If the hot water pipe is too long, it should be insulated to reduce heat loss.
  • When setting a power socket, determine the installation position according to the actual length of the cable.

Test Run

  1. After all installation is completed, open all valves in the pipeline, then open the hot water tap, fill the appliance with water and close the hot water tap. Check whether the pipes are leaking. If so, reconnect the pipes.
  2. Unscrew the stop screw at the handle of the safety valve, pull the handle of the safety valve, and check whether the water discharge of the safety valve is smooth (continuous water outlet means normal).
  3. After confirming normal operation, switch on the power and run the appliance according to the operation method section. Power off and disconnect when all is well.

Product Specifications

ModelParameter CTWD15CM CTWD3OCM
Rated Capacity 15L 28L
Net Weight(anhydrous condition) 8kg 11.2kg
Rated Power 1500W
Product Size(AxBxCmm) 380x380x325mm 440x440x390mm
Rated Voltage 220-240V— / 50-60Hz
Rated Pressure 0.75MPa
Waterproofing Grade IPX4
Setting Temperature Range 30 to 75°C

Product Dimensions

Dimensions

Maintenance

Cleaning

  • Use dry cloth or wet cloth to dip a little of neutral cleaner to wipe water heater surface, do not use gasoline or other solvents, mustn’t spray water.

Descaling

  • According to the local water quality condition, when water heater using a certain time (usually 1 months), need to remove dirty scale: first turn off the water heater, close the inlet valve, separate the connection between inlet and outlet, empty inner tank water. After descaling, reinstall the inner tank connection between inlet and outlet.

Draining

  • With long-term outage or maintenance, first cut off the power supply, turn off the inlet water valve, separate the connection between the inlet and outlet water pipe, empty it by upside down, and reinstall the connection between the inner tank and the connection between inlet and outlet water pipe. When using again, the inner tank must be filled with water before connecting the power supply.

Replace magnesium anode

  • The magnesium anode is to prevent corrosion in the inner tank, which is a consumptive part. After installation, need to check once a year. If the magnesium anode is about to run out or has been run out, should be replaced immediately with the same specifications of the magnesium anode, to ensure the service life of the water heater.

Caution

  • Pull out the power plug before maintaining.
  • Non-professional maintenance personnel disassembly, maintenance and modification of water heater shall be strictly forbidden.
  • The safety valve (pressure relief devices) need to regular take action, to remove calcium carbonate sedimentary and prove that it is not blocked. If blocked, please repair in time.
  • Drainage must be within the container under the water temperature below 40 °C, avoid scald.

Warning

  • he pressure relief temperature of the safety valve may cause scalding.
  • Scalding may occur if the temperature is set to more than 50°C. It mustbe mixed with cold water before use.
  • The appliance uses 220-240V~/50Hz power supply.
  • Do not pull or plug the power plug with wet hands.
  • Do not close the water inlet valve, and do not tumn on the power supply when the appliance is not filled with water, so as not to damage the appliance.
  • The safe service life is 8 years. When the product is still used after the safe service life, it may cause fire or injury due to the deterioration of quality as years of disrepair.
  • Do not allow children to operate the appliance to avoid accidental injury.
  • Please confirm the actual water temperature before use to avoid too low or too high water temperature.
  • Tumn the thermostat to the lowest temperature before unplugging the power plug.
  • Periodically pull the safety valve handle to check whether the relief valve drain is unblocked. If not, please contact us.
  • In cold areas, when the appliance is not used for a long time in winter, the water should be emptied to prevent the appliance from freezing and damage.
  • When the appliance is installed under the sink, check frequently whether the sink is leaking to avoid danger to the appliance.

Method of Usage

  • Water Injection
    When the water heater use at the first time or used again after outage for a long time, should inject water. Open all valves in pipeline, and then turn on the hot water tap. When the water continuously flow, it replies that water heater have been filled with water. Turn off the hot water tap, kept cold water pipe valve opening, make sure that cold water could automatically add after hot water usage. And make appliance has always been filled with water.

  • Switch on power
    Insert the power plug into reliable electric grounding outlet, switch on the power, the power indicator will lighten, according to the following method to adjust the temperature control knob, water heater immediately operates.

  • Temperature regulation
    Adjust temperature by temperature control knob. Turn clockwise to raise the setting temperature, turn anticlockwise to lower the setting temperature, and the temperature adjustment range is about 75°C at room temperature. After setting the temperature, the water heater automatically work and the heating indicator lights up. When the water temperature reaches the setting temperature, the power will be cut off automatically, and the heating indicator will light out to enter the heat preservation state. When the water temperature falls in some period, the water heat automatically again and the heating indicator lights up. When set to “OFF”, water heater will not work.
    Temperature Control Knob

Identify and Deal with Common

Identify and Deal with Common Faults
If water heater broke down during normal use, please immediately cut off the power, check according to the following content.

Faults

  • No flowing water
  • No hot flowing water
  • Flowing water com out hot and cold
  • Water drips from safety valve outlet
  • Water continuously drips from safety valve outlet

Wiring diagram

Wiring Diagram

Documents / Resources

| Corbero CTWD15CM Electric Water Heater [pdf] User Manual
CTWD15CM, CTWD30CM, CTWD15CM Electric Water Heater, Electric Water Heater, Water Heater, Heater
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals