PHILIPS BRP591 RoadFlair Pro Street Light Instruction Manual

June 12, 2024
Philips

PHILIPS-LOGO

PHILIPS BRP591 RoadFlair Pro Street Light

Product Information

The RoadFlair Pro is a lighting fixture with the following specifications:

  • Model: RoadFlair Pro
  • Mounting Instruction: 4441 702 64751
  • Standards: AS/NZS 1158.6, RoHS
  • IP Rating : IP66
  • Input Voltage: 220-240V
  • Frequency: 50/60Hz
  • Impact Protection: IK08
  • Temperature Ambient (GM): ta50
  • Temperature Ambient (AS/NZS): ta40

The technical description of the product is as follows:

LEDs Power/W (max.) Driver Qty Class Weight (kg)

42 42 42 60 60 60 60 42 42 42 60 60 60 60 72 72 72 72 72 96 96
96 96 96 96 96 96 114 114 114 114 114 114 15 15| 70 80 90 100 110 120 130 70 80 90 100 110 120 130 110 120 130
140 150 160 170 180 190 200 210 220 230 210 220 230 240 250 240 13
14| 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1| I I I I I I I I I I I I I I I I I I I I I I I I II II| 3.3 3.5 4.0 4.6 3.1 0.11 0.13 0.08
99 99 99 99 99 117 117 117 117 117 144 144 144 144 144 144 144
144 144 144 144 144 144 144 144 30 30 45 45 42 42 60 60 72 72| 160 170 180 190 200 210 220 230 240 250 260 270 280 290 300 35
43 51 59 65 68 76 84 92 100| 2| I I I I I I I I I I I I I I I I I I I I I I II II II II II II
II II II| 7.1
6.3| 4.0| 0.18| 0.11

This product is classified as energy efficiency class D.

The maximum number of luminaires that can be connected to an MCB 16A Type C is 5. The maximum number of luminaires that can be connected to an MCB 16A Type B is 11. The electrical circuit’s touch current or protective conductor current may vary depending on the electrical supply cables used, their rating and length, proper connection of electrical supply cables to luminaires, wiring connection topology of luminaires, and other site conditions.

PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-1

TECHNICAL DESCRIPTION

Technical Description| LEDs| Power/W

( max. )

| Driver

Qty

| Class| Weight

(kg)

| Wind force

area (m²)

---|---|---|---|---|---|---
BRP591 42LED(265-275)| 42| 70| 1| I|

≈3.3

|

0.08

BRP591 42LED(305-315)| 42| 80| 1| I
BRP591 42LED(340-350)| 42| 90| 1| I
BRP592 60LED(270-280)| 60| 100| 1| I|

≈3.5

|

0.09

BRP592 60LED(300-305)| 60| 110| 1| I
BRP592 60LED330| 60| 120| 1| I
BRP592 60LED350| 60| 130| 1| I
BRP593 42LED(260-275)| 42| 70| 1| I|

≈4.0

|

0.11

BRP593 42LED(305-310)| 42| 80| 1| I
BRP593 42LED(340-350)| 42| 90| 1| I
BRP593 60LED(270-280)| 60| 100| 1| I
BRP593 60LED(300-305)| 60| 110| 1| I
BRP593 60LED(330-335)| 60| 120| 1| I
BRP593 60LED350| 60| 130| 1| I
BRP593 72LED250| 72| 110| 1| I
BRP593 72LED275| 72| 120| 1| I
BRP593 72LED(300-305)| 72| 130| 1| I
BRP593 72LED(320-330)| 72| 140| 1| I
BRP593 72LED(345-350)| 72| 150| 1| I
BRP594 96LED(275-285)| 96| 160| 1| I|

≈4.6

|

0.13

BRP594 96LED(295-300)| 96| 170| 1| I
BRP594 96LED(310-315)| 96| 180| 1| I
BRP594 96LED330| 96| 190| 1| I
BRP594 96LED(345-350)| 96| 200| 1| I
BRP594 96LED365| 96| 210| 1| I
BRP594 96LED385| 96| 220| 1| I
BRP594 96LED400| 96| 230| 1| I
BRP594 114LED(305-310)| 114| 210| 1| I
BRP594 114LED325| 114| 220| 1| I
BRP594 114LED335| 114| 230| 1| I
BRP594 114LED350| 114| 240| 1| I
BRP594 114LED350| 114| 250| 1| I
BRP594 114LED354| 114| 240| 1| I
BRP591 15LED140| 15| 13| 1| II|

≈3.1

|

0.08

BRP591 15LED144 WW| 15| 14| 1| II
Technical Description| LEDs| Power/W

( max. )

| Driver

Qty

| Class| Weight

(kg)

| Wind force

area (m²)

---|---|---|---|---|---|---
BRP595 99LED(265-270)| 99| 160| 2| I|

≈7.1

|

0.18

BRP595 99LED(280-285)| 99| 170| 2| I
BRP595 99LED(300-305)| 99| 180| 2| I
BRP595 99LED(315-320)| 99| 190| 2| I
BRP595 99LED(330-335)| 99| 200| 2| I
BRP595 117LED300| 117| 210| 2| I
BRP595 117LED(310-315)| 117| 220| 2| I
BRP595 117LED(320-330)| 117| 230| 2| I
BRP595 117LED(335-345)| 117| 240| 2| I
BRP595 117LED350| 117| 250| 2| I
BRP595 144LED(300-305)| 144| 260| 2| I
BRP595 144LED(310-315)| 144| 270| 2| I
BRP595 144LED(320-325)| 144| 280| 2| I
BRP595 144LED(330-340)| 144| 290| 2| I
BRP595 144LED(340-350)| 144| 300| 2| I
BRP595 144LED40 O5| 144| 35| 1| I|

≈6.3

|

0.18

BRP595 144LED50 O5| 144| 43| 1| I
BRP595 144LED60 O5| 144| 51| 1| I
BRP595 144LED70 O5| 144| 59| 1| I
BRP595 144LED78 O5| 144| 65| 1| I
BRP595 144LED80 O5| 144| 68| 1| I
BRP595 144LED90 O5| 144| 76| 1| I
BRP595 144LED100 O5| 144| 84| 1| I
BRP595 144LED110 O5| 144| 92| 1| I
BRP595 144LED120 O5| 144| 100| 1| I
BRP593 30LED121| 30| 22| 1| II|

≈4.0

|

0.11

BRP593 30LED125 WW| 30| 23| 1| II
BRP593 45LED124| 45| 34| 1| II
BRP593 45LED128 WW| 45| 35| 1| II
BRP593 42LED217| 42| 55| 1| II
BRP593 42LED224 WW| 42| 57| 1| II
BRP593 60LED321| 60| 115| 1| II
BRP593 60LED332 WW| 60| 119| 1| II
BRP593 72LED314| 72| 134| 1| II
BRP593 72LED325 WW| 72| 139| 1| II

Factory Description
BRP59x LEDaaa/bb cccW dddV eee fff hhh IlI |J. The explanation for model list BRP59X:x= | denotes small version housing, x=2 denotes middle version housing, x=3 denotes middle plus version housing, x=4 denotes large version housing, x=5 denotes large plus version housing; aaa denotes rated lumen output, could be 90, 91 to 494, E.g. aaa=494, the rated lumen output 49400lm;bb denotes color temperature, CW=Cool White, NW=Neutral White, WW=Warm White, 727=CRI70&2700K, 722=CRI70&2200K; ccc denotes rated system power, E.g ccc=300, the rated system power 300W; ddd denotes 220-240V or 120 -270V also can be blank; eee denotes Lens type: DM/DMI/DW2/DWV/DWP/DWP3; ff denotes type of insulation protection, I1/nil, nil means class I; gag denotes type of driver, PSR/PSD/GL/TWE/PSA/PSRD/SR/nil; hhh denotes socket, P7/P7T SRB/SRB/nil; iii denotes LED type, E.g. 05/nil; jij denotes country code: ANZ/GM/nil, nil means blank.

This product contains a light source of energy efficiency class: D

*Maximum Number of Luminaire on MCB 16A Type C

1.6 Time of type B for MCB 16A

| *Maximum Number of Luminaire on

MCB 16A Type B

| Alternative Program Driver Inrush

Current

|

Driver Description

|

Product

|

Driver Qty

---|---|---|---|---|---

The electrical circuit Touch current or protective conductor current (in some cases referred to Earth Leakage Current) may be greatly dependent upon electrical supply cables used such as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions.

| 5| 46A/440us @230V| Xitanium Dim 150W 1.05A 1-10V 230V Y| BRP595 PSR| 2
11| 46A/440us @230V| Xitanium Dim 150W 1.05A 1-10V 230V Y| BRP593 PSR| 1
11| 46A/440us @230V| Xitanium Dim 150W 1.05A 1-10V 230V Y| BRP592 PSR| 1
11| 46A/440us @230V| Xitanium Dim 150W 1.05A 1-10V 230V Y| BRP591 PSR| 1
4| 78A/174us @230V| EP 150W 1-10V WL IP42| BRP595 PSA| 2
4| 78A/238us @230V| EP 250W 1-10V WL IP42 1.05-1.5| BRP594 PSA| 1
6| 175A/100us @230V| EP 200W 1-10V WL IP42 0.86-1.3| BRP594 PSA| 1
9| 78A/174us @230V| EP 150W 1-10V WL IP42| BRP593 PSA| 1
9| 78A/174us @230V| EP 150W 1-10V WL IP42| BRP592 PSA| 1
9| 79A/122us @230V| EP 100W 1-10V WL IP42| BRP592 PSA| 1
9| 79A/122us @230V| EP 100W 1-10V WL IP42| BRP591 PSA| 1
4| 45A/315μs @230V| Xi LP 150W 0.3-1.05A S1 WL I175| BRP595 PSRD| 2
8| 53A/300μs @230V| Xi LP 150W 0.2-0.7A S1 230V S240 sXt| BRP595 PSRD| 1
4| 44A/422μs @230V| Xi LP 250W 0.3-1.05A S1 WL B215| BRP594 PSRD| 1
2| 51A/585μs @230V| Xi LP 220W 0.3-1.05A S1 230V F3| BRP594 PSRD| 1
9| 45A/315μs @230V| Xi LP 150W 0.3-1.05A S1 WL I175| BRP593 PSRD| 1
9| 45A/315μs @230V| Xi LP 150W 0.3-1.05A S1 WL I175| BRP592 PSRD| 1
9| 48A/278μs @230V| Xi LP 100W 0.3-1.05A S1 WL I155| BRP592 PSRD| 1
9| 48A/278μs @230V| Xi LP 100W 0.3-1.05A S1 WL I155| BRP591 PSRD| 1
11| 46A/250μs @230V| Xi LP 75W 0.2-0.7A S1 230V S240 sXt| BRP595 PSRD| 1
4| 53A/300μs @230V| Xi FP 150W 0.3-1.05A SDAE 230V F sXt| BRP595 PSD| 2
8| 53A/300μs @230V| Xi FP 150W 0.3-1.05A SDAE 230V F sXt| BRP593 PSD| 1
4| 53A/300μs @230V| Xi FP 150W 0.3-1.0A SNLDAE 230V S240 sXt| BRP595 PSD| 2
8| 53A/300μs @230V| Xi_FP_150W_0.2-0.7A_SNLDAE_230V_S240_sXt| BRP595 PSD| 1
8| 53A/300μs @230V| Xi FP 150W 0.3-1.0A SNLDAE 230V S240 sXt| BRP593 PSD| 1
11| 46A/250μs @230V| Xi_FP_75W_0.2-0.7A_SNLDAE_230V_S240_sXt| BRP595 PSD| 1
11| 46A/250μs @230V| Xi FP 75W 0.3-1.0A SNLDAE 230V S240 sXt| BRP593 PSD| 1
7| 37A/500μs @230V| Xi SR 150W 0.3-1.0A SNEMP 230V S240 sXt| BRP595 SR| 2
15| 37A/500μs @230V| Xi_SR_150W_0.2-0.7A_SNEMP_230V_S240_sXt| BRP595 SR| 1
15| 37A/500μs @230V| Xi SR 150W 0.3-1.0A SNEMP 230V S240 sXt| BRP593 SR| 1
31| 30A/420μs @230V| Xi_SR_75W_0.2-0.7A_SNEMP_230V_S240_sXt| BRP595 SR| 1
31| 30A/420μs @230V| Xi SR 75W 0.3-1.0A SNEMP 230V S240 sXt| BRP593 SR| 1
2| 55A/530μs @230V| Xi LP 150W 0.3-1.05A S1 GL 200| BRP595 GL| 2
5| 88.5A/220μs @230V| Xi LP 220W 0.3-1.05A S1 TWE I230| BRP594 TWE| 1
4| 55A/530μs @230V| Xi LP 150W 0.3-1.05A S1 GL 200| BRP593 GL| 1
7| 44A/400μs @230V| Xi LP 100W 0.3-1.05A S1 GL I175| BRP592 GL| 1
7| 44A/400μs @230V| Xi LP 100W 0.3-1.05A S1 GL I175| BRP591 GL| 1
9| 79A/122us @230V| EP 100W 1-10V WL IP42| BRP593 PSA| 1
9| 48A/278μs @230V| Xi LP 100W 0.3-1.05A S1 WL I155| BRP593 PSRD| 1
7| 44A/400μs @230V| Xi LP 100W 0.3-1.05A S1 GL I175| BRP593 GL| 1
26| 21A/225μs @230V| Xi FP 40W 0.3-1.0A SNLDAE 230V S175 sXt| BRP593 PSD| 1
29| 15A/295μs @230V| Xi FP 22W 0.3-1.0A SNLDAE 230V S175 sXt| BRP591 PSD| 1

PRODUCT SIZE

PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-4

INSTALLATION

Shorting cap (only for P7 NEMA/SRB version)

  1. Shall be fixed by a qualified electrician.
  2. Shall be fixed clockwise until the end. Rotation angle is about 10°。
  3. Shorting cap provided with the luminaire is rated for 3 years service life.
  4. Shorting cap should be replaced with intended device or replaced within 3 years.

Node and sensor installation refer to their MI.
Note: Must use Signify suggested short cap to ensure IP66

Open the cover

(Only for GM, With 8M cable for ANZ

  1. Press the cover by hand and slide from lock to unlock.
  2. Open the cover.

PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-6

Connect the power cord

Only for GM, With 8M cable for ANZ II)

PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-7PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-8

MORE INFO

PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-9 PHILIPS-BRP591-RoadFlair-Pro-Street-Light-FIG-10

©2020 Signify Holding
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.

  • Signify Holding
  • The Netherlands

Please inform yourself about the local waste disposal, separation and collection system for electrical and electronic products and packaging. Please act
according to your local rules and do not dispose your old product and packaging with your normal household waste. The correct disposal of the packaging, your product and/or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed separately from the municipal waste stream via designated collection facilities. When disposing a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional.

Waming

  1. The luminaire shall be installed by a qualified electrican and wired in accordance with the latest IEEE electrical regulations or the national requirements.
  2. Turn power off before inspection, installation or removal.
  3. The light source and/or control gear contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
  4. Refer to technical datasheet for additional electrical properties to ensure safe installation.
  5. Luminaire installed must not be in contact with combustible materials.
  6. Ensure power supply cables (L-N/ L-N-E) are connected correctly before switching on.

Maintenance

  1. Ensure power supply is switched off before attempting any maintenance work.
  2. Periodic cleaning of the luminaire optical lens cover will ensure maximum optical efficiency.
  3. Luminaire optical lens cover shall be cleaned with clean water and non-abrasive soap, cleaner or detergent solution.

Caution: The Luminaire must be used within the applicable product specifications, installation instructions and environmental conditions for storage & operations according to application guidelines provided by Signify for product Warranty to be valid.

CONTACT

  • Signify (China) Investment Co., Ltd.
  • ADDRESS: Building No. 9, Lane 888 Tianlin Road, Minhang District, Shanghai, China
  • Postal code: 200233

Philips and the Philips shield emblem are registered trademarks of Koninklijke Philips N.V.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals