HACH CL17sc Colorimetric Chlorine Analyzer Owner’s Manual

June 12, 2024
HACH

HACH CL17sc Colorimetric Chlorine Analyzer

Product Information

By pairing the Ultra Low Range CL17sc with Hach’s SC controller platform, your options increase significantly: internal data logging; external analog and digital communication alternatives; and multi-parameter instrument flexibility.

Ultra Low Range CL17sc with Standpipe Installation Kit PN9790200

  • Comes with Ultra Low Range CL17sc analyzer, standpipe installation kit, tubing kit, and user manual.
  • Hach SC controller is required to operate the Ultra Low Range CL17sc. Compatible with all current Hach SC controllers.

Ultra Low Range CL17sc with Pressure Regulator Installation Kit PN9790300

  • Comes with Ultra Low Range CL17sc analyzer, pressure regulator installation kit, tubing kit, and user manual.
  • Hach SC controller is required to operate the Ultra Low Range CL17sc. Compatible with all current Hach SC controllers.

Cumulative Chlorine Counter™
Understand the true impact of chlorine exposure. The Ultra Low Range CL17sc allows for process control across your water cycle, including visibility into GAC exhaustion or channeling and dechlorinating agent dosage. It is the only instrument with a cumulative chlorine counter, which helps you forecast your RO membrane efficiency and its useful life.

Accuracy at Lower Range
With a limit of detection of 8 ppb, you can take control of your dechlorination process, protect your assets from chlorine damage, and meet strict residual chlorine limits.

Parts per Billion Reading
Eliminate reading confusion when process adjustments and chlorine discharge require ultra low range control.

Total chlorine confidence. From the global leader in chlorine analysis.
Meet your unique water cycle needs with the new Ultra Low Range CL17sc online total chlorine analyzer from Hach®. Whether treating utility water, product water, or wastewater discharge, you’ll have the direct chlorine measurements you need to optimize your process. You’ll be able to protect valuable assets and report to regulatory agencies with confidence.

Applications

  • Drinking Water
  • Wastewater
  • Food and Beverage
  • Pharmaceutical
  • Power
  • Semiconductor
  • Field Use

OVERVIEW

HACH-CL17sc-Colorimetric-Chlorine-Analyzer- \(1\)

  1. Indicator bottle
  2. Measurement cycle lights
  3. Pump clamp
  4. Pump tubing assembly
  5. Analyzer status light
  6. Flow meter
  7. Buffer bottle
  8. Cell

Monitor and Optimize your Dechlorination process

Chlorine breakthroughs can adversely affect your process, product, or equipment. You’ll be able to mitigate issues and optimize your process with the Hach Ultra Low Range CL17sc analyzer, which has the lowest limit of detection at less than 8 ppb. It’s time to accurately measure your total residual chlorine and take control of your dechlorination process.

Depend on direct measurements
Online residual chlorine measurement options for ultra-low range have been either inadequate or inefficient – until now. The Ultra Low Range CL17sc gives you direct total chlorine results, eliminating the need for ORP or amperometric measurement. The Ultra Low Range CL17sc uses colorimetric DPD Standard Method 4500-Cl G and consistently maintains accuracy without loss of sensitivity in your new target range.

Protect your assets
Understand the true impact of chlorine exposure. The Ultra Low Range CL17sc allows for process control across your water cycle, including visibility into GAC exhaustion or channeling and dechlorinating agent dosage. It is the only instrument with a cumulative chlorine counter, which helps you forecast your RO membrane efficiency and its useful life.

Connect with Claros
When the new Ultra Low Range CL17sc analyzer is connected to Claros™, Hach’s Water Intelligence system, it provides realtime visibility into your processes so you can optimize and automate your chlorination/dechlorination. You’ll have peace of mind and more time to focus on high-value tasks.

Technical Data

  • Range 0.008 – 5 mg/L Cl2
  • Accuracy ± 5% or ± 0.01 mg/L (whichever is greater) from 0 – 4 mg/L; ± 10% from 4 – 5 mg/L
  • Lower Limit of Detection (LOD) 0.008 mg/L Cl2 at 25 °C
  • Cycle Time 2.5 minutes
  • Inlet Pressure
    • 0.3 – 5.2 bar (4.5 – 75 psig) supplied to Y-strainer
    • 0.1 – 0.3 bar (1.5 – 5 psig) supplied to analyzer
  • Inlet ¼-inch OD polyethylene tube, quick-disconnect fitting
  • Drain ½-inch ID flexible hose
  • Air Purge Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar (20 psig) maximum
  • Sample Requirements Y-strainer filtration with 40-mesh screen or higher
  • Sample Flow Rate 60 – 200 mL/min through the instrument
  • Sample Temperature 5 – 40 °C (41 – 104 °F)
  • Operating Temperature Range 5 – 40 °C (41 – 104 °F)
  • Operating Humidity 0 – 90% relative humidity, non-condensing
  • Interferences Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference.
  • Reagent Consumption 0.5 L of buffer solution and 0.5 L of indicator solution in 31 days
  • Certifications
    • CE compliant with: EN 61326-1, CISPR 11, EN 50581 ACMA RCM South Korea KC Certificate
    • North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003
  • Light Source LED, measurement at 510 nm, 1 cm light pathlength
  • Enclosure Rating IP66
  • Mounting Wall mount
  • Power Requirements (Voltage) 12 VDC, 400 mA maximum (supplied by the controller)
  • Dimensions ( H x W x D) 342 mm x 329 mm x 177 mm
  • Weight 4.1 kg (9.0 lbs.)

Principle of Operation
The Ultra Low Range CL17sc Colorimetric Chlorine Analyzer has three operating components:

  • A linear peristaltic pump to precisely control the volume of incoming samples and reagents
  • A colorimeter
  • Indicator and buffer solutions

A zero reference point is established at the beginning of the cycle by measuring blank absorbance. (This compensates for the sample’s color intensity and turbidity before the chlorine measurement is made.) Indicator and buffer solutions are then added to the sample while a magnetic stirrer mixes the solution and the sample changes color. A colorimeter then measures the light transmitted through the sample. The measured color intensity is compared to a reference standard. Finally, the sample cell is flushed with new sample so that the cycle can repeat every 2.5 minutes.

Dimensions

The Ultra Low Range CL17sc is designed to be wall-mounted with four ¼-inch screws. Adequate clearance must be left for plumbing and controller connection. The sample inlet connection is a ¼-inch quick-connect fitting and the drain connection is ½-inch ID flexible hose. The analyzer receives power from connection to a Hach SC controller. (The analyzer’s cable is approximately 6.5 ft. in length.)

HACH-CL17sc-Colorimetric-Chlorine-Analyzer- \(7\) HACH-CL17sc-Colorimetric-Chlorine-Analyzer- \(8\)

Order Information

Hach Ultra Low Range CL17sc Colorimetric Chlorine Analyzers are shipped with an installation kit, user manual, and one month of reagents where noted. The user selects a standpipe installation kit or a pressure regulator installation kit at the time of purchase. Hach SC controllers are required for operation and are sold separately.

Ultra Low Range CL17sc Colorimetric Chlorine Analyzers

  • 9790200 Ultra Low Range CL17sc Colorimetric Chlorine Analyzer with Standpipe Installation Kit
  • 9790300 Ultra Low Range CL17sc Colorimetric Chlorine Analyzer with Pressure Regulator Installation Kit
  • 9793300 Ultra Low Range CL17sc Colorimetric Chlorine Analyzer with Standpipe Installation Kit and Reagents for Total Chlorine
  • 9793400 Ultra Low Range CL17sc Colorimetric Chlorine Analyzer with Pressure Regulator Installation Kit and Reagents for Total Chlorine

Accessories

  • 8568200 CL17sc Calibration Verification Kit
  • 8573200 CL17sc Calibration Verification Refill Kit
  • 8560500 CL17sc Standpipe Installation Kit
  • 8565700 CL17sc Pressure Regulator Installation Kit

Reagents and Consumables

  • 9791100 Ultra Low Range Total Chlorine Reagents Set
  • 8560400 CL17sc Tubing Kit (pre-assembled)
  • 8573100 CL17sc Cell Cleaning Kit

This instrument connects to Claros, Hach’s innovative Water Intelligence System. Claros allows you to seamlessly connect and manage instruments, data, and process – anywhere, anytime. The result is greater confidence in your data and improved efficiencies in your operations. To unlock the full potential of Claros, insist on Claros Enabled instruments.

With Hach Service, you have a global partner who understands your needs and cares about delivering timely, high-quality service you can trust. Our Service Team brings unique expertise to help you maximize instrument uptime, ensure data integrity, maintain operational stability, and reduce compliance risk.

Features

HACH-CL17sc-Colorimetric-Chlorine-Analyzer- \(9\)

| CL17| CL17sc| Ultra Low Range CL17sc
---|---|---|---
Accuracy at Lower Range With accuracy in the parts-per-billion measurement range, you can take control of your dechlorination process, protect your assets from chlorine damage, and meet strict residual chlorine limits.| | | 
Cumulative Chlorine Counter™ Understand the true impact of chlorine exposure on downstream assets over time by tracking chlorine exposure in ppm- hours.| | | 
Parts per Billion Reading Eliminate reading confusion when process adjustments and chlorine discharge require ultra low range control.| | | 
Reliable, Accurate Colorimetric Technology Reliable colorimetric DPD chemistry to continuously monitor water for chlorine.| | | 
Service Protected A complete portfolio of service plans to help you protect your investment and peace of mind.| | | 
Claros™ Enabled Claros – The Water Intelligence System from Hach. Claros provides greater confidence in your data, resulting in improved efficiencies in your plant’s operation.| | | 
Enhanced Connectivity Compatibility with the SC controller platform, giving users more flexibility to store, transfer, and interact with their process chlorine data.| | | 
Maintenance Made Easy Reduces your routine maintenance touch time with simplified tubing replacement and step-by-step, on-screen workflows.| | | 
Flow Sensor A built-in flow meter to notify you when there’s an unexpected change in flow that could compromise your measurements.| | | 

Technical Specifications

| CL17| CL17sc| Ultra Low Range CL17sc
---|---|---|---
Accuracy| ± 5 % or ±0.04 mg/L (ppm) as Cl2, (whichever is greater)| ±5% or ±0.04 mg/L from 0 to 5 mg/L (whichever is greater) as Cl2 ±10% from 5 to 10 mg/L as Cl2| ± 5% or ± 0.01 mg/L as Cl2 (whichever is greater) from 0 – 4 mg/L; ± 10% from 4 – 5 mg/L as Cl2
Communication Capabilities| 4-20mA Output| Current output, relays and bus communication via SC controller| Current output, relays and bus communication via SC controller
Cycle Time| Fixed 2.5 min.| Fixed 2.5 min.| Fixed 2.5 min.
Dimensions (H x W x D)| 45.4 cm x 31.4 cm x 17.9 cm (17.9 in. x 12.4 in. x 7.0 in.)| 32.9 cm x 34.2 cm x 17.7 cm (12.9 in. x 13.5 in. x 7.0 in.)| 32.9 cm x 34.2 cm x 17.7 cm (12.9 in. x 13.5 in. x 7.0 in.)
Controller| No| Hach SC controllers| Hach SC controllers
Enclosure Rating| IP62| IP66| IP66
Flow Meter| No| Yes| Yes
Measurement Range| 0-5 mg/L (ppm)| 0-10 mg/L (ppm)| 0-5 mg/L (ppm)
Limit of Detection (LOD)| 0.03 mg/L (ppm)| 0.03 mg/L (ppm)| 0.008 mg/L (ppm)

Hach World Headquarters: Loveland, Colorado USA
United States: 800-227-4224 tel 970-669-2932 fax [email protected]
Outside United States: 970-669-3050 tel 970-461-3939 fax [email protected]
hach.com

Printed in U.S.A.
©Hach Company, 2021. All rights reserved.
In the interest of improving and updating its equipment, Hach Company reserves the right to alter specifications to equipment at any time.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HACH User Manuals

Related Manuals