Beca BHT-7000 Smart Knob Thermostat User Manual
- June 12, 2024
- BECA
Table of Contents
Beca BHT-7000 Smart Knob Thermostat User Manual
New heating thermostat with knob BHT-7000 Six characteristics on the design
- 1.32 inch circular and 240*240 TFT shows your artistic taste.
- Superfine aluminum side knob lets your fingers feel delicate.
- Above 6H tempered glass keeps your screen away from scratches.
- Agile push button gives you an excellent experience.
- Seven colors ambient light increase color to your life.
- Variety brushed back panel options are suitable for different home styles.
ABOUT YOUR THERMOSTATS
The BHT-7000 range has been developed to control electric underfloor, water heating or water/ gas boiler systems. These units are designed for use in commercial, industrial, civil and domestic properties
MODEL DEFINITION
GA: Water heating, 5A
GB: Electric floor Heating, 16A
GC: Water/Gas Boiler, 5A
L: Backlight
N: Modbus Communication
W: Wifi
S2: Both internal sensor and floor external sensor
For example: BHT-7000GA
In the box you will find
Thermostat 1pc Screws 2pc
User Guide 1pc Wall plate 1pc
QC Passed 1pc
(Floor sensor is Optional)
TECHNICAL DATA
Power Supply:95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz
Please check the information laser printed on the back of the thermostat for
the actual voltage.
Current Load: 5A (water heating, gas boiler), 16A (electric heating)
Sensor: NTC3950, 10K
Accuracy: ±1°C
Set Temp. Range: 5-35°C
Room Temp. Range: 5-99°C
Display Temp. Range: 5 ~ 99°C
Ambient Temp.: 0~ 45°C
Ambient Humidity: 5 ~ 95 % RH (Non Condensing)
Storage Temp.:-10~ 45°C
Power Consumption: <1. 5W
Timing Error: < 1%
Shell Material: PC +ABS ( Fireproof)
Installation Box: 86 * 86mm Square or European 60mm Round Box
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2
Protection Class: IP20
Buttons: Capacitive Touch Buttons
DIMENSION: (mm)
BEFORE WIRING AND INSTALLING
- Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
- Check the rathings given in the instructions and on the product to make sure the product is suitable for your application.
- Installer must be a trained, experienced service technician.
- After installation is complete, check out product operation as provided in these instructions.
WIRING
Please check the information laser printed on the back of the thermostat for the actual voltage
Note:
GA is for water heating;
GB is for electric heating;
GC is for water/gas boiler;
NTC and Modbus is optional.
INSTALLATION
Your thermostat is suitable for installation within a standard 86mm pattress box or European 60mm pattress box.
Step 1. Keep power off. See Fig 1.
Step 2. Remove the mounting plate by pushing the display assembly. See Fig 2.
Step 3. Connect power supply, load into the appropriate terminals.
(see “Wiring your thermostat” for details).
Step 4. Fix the mounting plate into the wall with screws in the box(Fig 4).
Step 5. Fix the thermostat body and the mounting plate by the lower button(Fig
5).
Step 6. Installation complete(Fig 6).
CAUTION
Electrical Shock or Equipment Damage
Hazard. Can shock individuals orshort
equipment circuitry. Disconnect power supply before installation.
HOME SCREEN QUICK REFERENCE
Note:
The weather and humidity will be synchronized within 1 hour after the device
is connected to the Internet for the first time, and the weather will be
synchronized every hour thereafter.
Main control interface
Tip: Press the screen to enter the Main control interface.
OPERATION
During Power On
- Press the home screen to enter the control interface.
- Rotate the control interface to select
- Press the control interface to confirm
- Long press the control interface to return the home screen
-
Power
ON: The thermostat is controlling the heating device.
OFF: The thermostat stops controlling the heating device. -
Sensor types
In: Internal Sensor(to control the temp.)
Ou: External Sensor(to control the temp.)
AL: Internal/External Sensor (Internal sensor to control the temp., external sensor to limit the temp.) -
Clock
Clock setting, the wifi version will automatically synchronize the local time after networking. -
Brightness
Standby screen brightness setting. When set to 0, the screen will turn off the display. -
Mode
Manual Mode Programming mode (Schedule mode.) -
WiFi
ON: The thermostat is in the wifi distribution network state.
OFF: The thermostat is not in the wifi distribution network state -
Temp calibration
Please perform temperature correction after the thermostat has been working for 30 minutes. -
Set temp.
Set temperature range 5~45℃
Set week program on your App
Default settings for program schedule
Time display| WEEKDAY (MONDAY一FRIDAY)
(1 2 3 4 5 shows on screen)| WEEKEND (SATURDAY)
(6 shows on screen)| WEEKEND (SUNDAY)
(7 shows on screen)
---|---|---|---
TIME| TEMPERATURE| TIME| TEMPERATURE| TIME|
TEMPERATURE
Period 1| 06:00| 20 ℃| 06:00| 20 ℃| 06:00| 20 ℃
Period 2| 08:00| 15 ℃| 08:00| 20 ℃| 08:00| 20 ℃
Period 3| 11:30| 15 ℃| 11:30| 20 ℃| 11:30| 20 ℃
Period 4| 13:30| 15 ℃| 13:30| 20 ℃| 13:30| 20 ℃
Period 5(1+2)| 17:00| 22 ℃| 17:00| 20 ℃| 17:00| 20 ℃
Period 6(3+4)| 22:00| 15 ℃| 22:00| 15 ℃| 22:00| 15 ℃
A separate schedule may be set for weekdays (Mon – Fri) and for weekends (Sat or Sun).
ABOUT WIFI / WI-FI CONNECTION
Before using your Wi-Fi thermostat for the first time,you must configure the Wi-Fi signal and settings through your smartphone or tablet ,This will allow communication between your connected devices
Step 1 Downlosd your APP
Fig 1-1
Search for “Smartlife” in Apple Store or Google Play or use a browser to scan the QR code above (Figure 1-2), and complete account registration and installation according to the guidance of the APP.
Step 2. Connect the thermostat
Method 1: Bluetooth network distribution (Fig 2.1-Fig 2.4), turn on the Bluetooth switch of the mobile phone and set the thermostat to the WiFi enabled state, see the following tutorial to complete the connection and settings.
Method 2: Scan the QR code to configure the network guide
(Fig 2.5-Fig 2.9) complete the connection and setup
Method 3: Ordinary distribution network guidance
(Fig. 2. 5.1-Fig. 2.9)
APP operation interface description (heating thermostat))
More settings
SIMPLE EXCEPTION HANDLING
No. | Phenomenons | Handling |
---|---|---|
1 | Power is on but without display. | *Check if the terminals between LCD panel |
and Power Unit Box is loosen.
2| Without output but display works.| Usea new LC panel or new Power Unit
Box toreplace the old one.
3| Room Temp. Is a lttle different from the actual.| Do temperature
calibration in item 1 of high senior options
SERVICE
Your thermostat carries an 24 months warranty from date of purchase. Service out with the warranty period may incur a charge. More detail please contact with us directly.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>