PiXAPRO MF-R76 Macro Ring Flash Instruction Manual
- June 4, 2024
- PiXAPRO
Table of Contents
- PiXAPRO MF-R76 Macro Ring Flash
- Features
- Name of Parts
- What’s in the Box
- Battery
- Loading and Unloading the Battery
- Installation and Disassembly of the Controller
- Installation and Disassembly of the ring flash
- Operating Instructions
- C.Fn: Setting Custom Functions
- Flash power setting
- **** Other Protections
- Technical Data
- Maintenance
- FCC Statement
- Declaration of Conformity:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PiXAPRO MF-R76 Macro Ring Flash
Foreword
Thank you for purchasing!
MACRO MF-R76 is a macro ring flash with compact structure of flash body and
convenient controller. The A/B flash tube can fire independently, set flash power
output to achieve precise brightness control, and provide a variety of options
and creations. It can be widely used in macro shooting scenes such as insect
photography, plant photography, jewelry photography and dental photography.
Features
- No vignetting and no shadows in macro shooting.
- Accurate power adjustment from 1/1 full power to 1/128 at 1/3E Vincrement each stop.
- Guide No. GN14, stable manual flash output and instant filling.
- Merely 1.5s full-power flash recycling time.
- Lithium battery power supply, up to 660 flash times in 1/1 full power.
- Easy to install and suitable for camera lens with a diameter of 49mm-77mm.
- Two LED Focus Assist Beam are designed with 10 levels of brightness adjustment.
- Simple user’s interface, convenient and comfortable operation.
Warning
- Always keep this product dry.
- Keep out of reach of children.
- As this product is not waterproof, do not use in rain or in damp conditions.
- Do not leave or store the flash unit if the ambient temperature reads over 50℃. Otherwise the electronic parts may be damaged.
- Do not disassemble. Should repairs become necessary, this product must be sent to an authorized maintenance center.
- Stop using this product if it breaks open due to extrusion, falling or strong hit. Otherwise, electric shock may occur if you touch the electronic parts inside it.
- Do not fire the flash directly into the eyes (especially those of babies) within short distances. Otherwise visual impairment may occur.
- Do not use the flash unit in the presence of flammable gases, chemicals and other similar materials. In certain circumstance, these materials may be sensitive to the strong light emitting from this flash unit and fire or electromagnetic interference may result.
- Turn off the devices immediately in the event of malfunction.
Name of Parts
- Flash head
- LED Focus Assist Beam button (1~10 stops)
- A /B group selection dial
- C.Fn: Setting Custom Functions button
- RATIO button
- Flash trigger button
- SET button
- Select dial
- ON/OFF Power switch button
- Lock ring
- Hotshoe
- Flash tube A
- Flash tube B
- Battery remove button
- Controller
- 3.5mm sync cord jack
- Connecting cable
- Lithium battery
- Adapter ring connecting port
- Detaching mount
What’s in the Box
-
Macro ring flash×1
-
Lithium battery×1
-
USB charger×1
-
Type-C-USB charging cable×1,
-
Storage bag×1
-
Instruction Manual×1
Battery
- This product uses 7.2V/2600mAh lithium battery which has long runtime. The available charge-and-discharge times are 480.
- It is reliably safe. The inner circuit is against overcharge, over discharge, overcurrent, and short circuit.
- Take only 3.5 hours to fully charge the battery by using battery charger. VC1(5V 2A,optional)
Tips: Macro ring flash MACRO MF-R76 is compatible with PIXAPRO GIO1 lithium battery VB26 and CITI100Pro lithium battery WB100 lithium battery
Cautions
- Do not short circuit.
- Do not expose to rain or immerse into water. This battery is not water proof.
- Keep out of reach of children.
- No over 24 hours’ continuous charging.
- Store in dry, cool, ventilated places.
- Do not put aside or into fire.
- Dead batteries should be disposed according to local regulations.
- If the battery had ceased using for over 3 months, please make a full recharge.
- Please charge the battery to approx. 60% before being placed for long time.
- Please replace a new battery after charging-and-discharging over 500 times or being used over 3 years.
Loading and Unloading the Battery
-
Unloading(1)
Long press the battery remove button and push right the battery to unload it. -
Loading(2)
Insert the lithium battery according to the direction, push in until it is locked.
Installation and Disassembly of the Controller
-
Loosening the lock ring
Rotate anticlockwise to loosen the lock ring. -
Installing the controller
Slide the hotshoe to completely insert it into the camera’s socket. -
Securing the lock ring
Rotate clockwise to secure the lock ring.
Installation and Disassembly of the ring flash
-
Installing the lens adapter ring
Rotate clockwise the proper adapter ring and mount it to the front of the lens.
Tips: There are 8 adapter rings applicable to MACRO MF-R76: 49mm, 52mm, 55mm, 58mm, 62mm, 67mm, 72mm and 77mm. -
Installing the ring flash
Insert the lens with adapter ring into the adapter ring connecting port until it is locked.
Note: It is normal that the mounted ring flash can be rotated 360°. -
Disassembling the ring flash
Slightly pull out the remove buckle on the back, and then rotate to the right to remove the ring flash.
Operating Instructions
-
Power switch
Toggle ON/OFF Power switch button toto power on, and to power off. -
Focus Assist Beam
Short press the LED Focus Assist Beam button to turn on or turn off the Focus Assist Beam. -
Modeling light adjustment:
Turn on the Focus Assist Beam short press SET button to enter the setting interface, then turn the select dial to adjust in 1-10 stops. -
A/B flash setting switch
Short press A/B flash selection dial to switch to A/B flash setting interface, turn the select dial to set flash output from 1/1 full power to 1/128 with 1/3 increment at each stop.
C.Fn: Setting Custom Functions
- Backlight dormancy setting
This product has backlight dormancy function to avoid battery consumption in long period of idle use.
Short press < > C.Fn button to enter the custom function setting interface, with “BL”(Backlight) and “dormancy time” displayed on the LCD panel. The dormancy time is set to 10s by default. You can change or turn off the dormancy time by turning the select dial, after which press the <C.Fn:> C.Fn button to return to the previous interface
Backlight Dormancy Setting
|
Description
---|---
ON| The backlight is constantly on.
OFF| The backlight is turned off, it is in the state of no backlight.
10s| Idle time before entering backlight dormancy mode is set to 10s.
20s| Idle time before entering backlight dormancy mode is set to 20s.
2. Auto sleep setting
This product has auto sleep function to avoid battery consumption in long
period of idle use.
Short press < > C.Fn button to enter the custom function setting interface,
with “SL”(Sleep) and “sleeping time” displayed on the LCD panel. The sleeping
time is set to 30min by default. You can change or turn off the sleeping time
by turning the select dial, after which press the < > C.Fn button to return
to the previous interface.
Auto sleep setting | Description |
---|---|
OFF | The Sleep Function is turned off. The flash unit will not automatically |
enter sleep mode.
30min| Idle time before entering sleep mode is set to 30 minutes. Press any
button to waken.
60min| Idle time before entering sleep mode is set to 60 minutes. Press any
button to waken.
Flash power setting
Short press RATIO button to switch among AB flash power common adjustment—A、B flash power individual adjustment—A flash power adjustment—B group flash power adjustment. You can set the manual flash output from 1/1 full power to 1/128 with 1/3 increment a teach stop by turning the select dial. The flash can fire in one of the four modes: 1. A group fires in the same power with B group, 2. A group fires in the different power with B group, 3. Only A group fires, 4. Only B group fires.
-
AB flash power common adjustment
-
A、B flash power individual adjustment
-
A flash power adjustment
-
B flash power adjustment
Note: The A、B flash power individual adjustment interface displays A flash
power adjustment by default, for B flash power adjustment, you need to switch
to B flash then turn the select dial.
Compatible Camera Models
This flash unit can be used on the following camera models: Canon, Nikon, Sony,
Fuji, Olympus, Panasonic, Pentax.
Over-Temperature Protection
- To avoid overheating and deteriorating the flash head, do not fire more than 35 continuous flashes in fast succession at 1/1 full power. After 35 continuous flashes, allow a rest time of at least 10 minutes.
- If you fire more than 35 continuous flashes and then fire more flashes in short intervals, the inner overtemperature protection function may be activated and < > is shown on the LCD panel. If this occurs, allow a rest time of about 10 minutes, and the flash unit will then return to normal.
Number of flashes that will activate over-temperature protection:
Power Output Level
|
Number of Flashes
---|---
1/1
| 35
1/2|
60
1/4
| 120
1/8|
196
1/16
| 285
1/32|
465
1/64
| 820
1/128|
1750
**** Other Protections
Prompts on LCD Panel
|
Meaning
---|---
E0| A failure occurs on the temperature sensor. Please send this kit to a
maintenance center.
El| A failure occurs on the recycling system so that the flash cannot fire.
Please restart the flash unit. If the problem still exists, please send this
product to a maintenance center.
E2| The system gets excessive heat. Please allow a rest time of 10 minutes.
E3| The voltage on two outlets of the flash tube is too high. Please send this
product to a maintenance center.
Technical Data
Product Name | Macro Ring Flash |
---|---|
Model | **** MACRO MF-R76 |
Guide No. | GN14 /46(IS0 100、in meter/feet) |
Compatible Cameras | Canon, Nikon, Sony, Fuji, Olympus, Panasonic, Pentax |
Lithium Battery | 7.2V/2600mAh |
Flash Power (1/1 Power Output) | 76Ws |
Focus Assist Beam Power | 0.7W*2 |
Focus Assist Beam CCT | 5000K |
Flash Power Range | 1/1-1/128(with 1/3 increment a teach stop) |
Flash Duration | 1/300s~1/20000s |
Inner Diameter of Light Body | 77mm |
Illuminating Distance | 3cm~1.5m |
Recycle Time | 0.1-1.5s |
Full Power Flashes | 660times |
Working Environment Temperature | -10~50℃ |
Ring Flash Dimension | 13013027mm/5.15.11 inches |
Controller Dimension | 1207050mm/4.72.71.9 inches |
Net Weight | ≈458g/16.1oz |
Net Weight (with battery) | ≈577g/20.3 oz |
Maintenance
- Shut down the device immediately should abnormal operation be detected.
- Avoid sudden impacts and the product should be dedusted regularly.
- It is normal for the flash tube to be warm when in use. Avoid continuous flashes if unnecessary.
- Maintenance of the flash must be performed by our authorized maintenance department which can provide original accessories.
- This product, except consumables e.g. flash tube, is supported with a one-year warranty.
- Unauthorized service will void the warranty.
- If the product had failures or was wetted, do not use it until it is repaired by professionals.
- Changes made to the specifications or designs may not be reflected in this manual.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Declaration of Conformity:
PIXAPRO Photo Equipment Co,Ltd. hereby declares that the This equipment are in compliance with the essential requirements and other relevant provisions of EU Directive 2014/30/EU. They are allowed to be used in all EU member states.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>