DENT INSTRUMENTS CT-CON-0150EZ-U 150A EZ Clamp Current Transformer Owner’s Manual
- June 12, 2024
- DENT INSTRUMENTS
Table of Contents
CT-CON-0150EZ-U 150A EZ Clamp Current
Transformer
Owner’s Manual
CT-CON-0150EZ-U 150A EZ Clamp Current Transformer
HIGH PERFORMANCE CLAMP-ONCURRENT TRANSFORMER
150A EZ Clamp
DENT’s affordable and compact 150A EZ Clamp current transformers are the one-
handed operating solution for temporary or long-term studies. They are
designed to work in tight places and clamp around insulated cables or wires.
DENT’s energy monitoring components are used for a variety of applications,
including building automation, tenant submetering, performance verification,
energy management and new technology assessment.
KEY SPECIFICATIONS
Window Size | 1” (25 mm) |
---|---|
Current Range | .5 to 300A AC |
Output | 333 mV @ 150 A AC |
2.22 mV/A AC
Accuracy| <1% From .5– 300 A AC
Phase Shift| <1° From 5-25 A AC
1° From 25-150 A AC
<1.5° from 150-300 A AC
ELECTRICAL
Max Output
Wire Polarity
Phasing
Orientation
Frequency Range| 666 mV @ 300 A
Red = High, positive (+)
Black = Low, negative (-)
Label on Case Points
Toward Source
50 Hz to 400 Hz
---|---
MECHANICAL
Case Material
Leads
Working Temperature| White ABS, UL 94 V-0
8’ (2.4M), 22 gage, 600V
-25° to 70 °C (-13° to 158 °F )
---|---
SAFETY
Working Voltage
Dielectric Strength
Certifications| 600 VAC Category III
5200 VAC, 50/60 Hz for one minu
Conforms to:
UL STD 61010-1
Certified to:
CAN/CSA STD C22.2 No. 61010-1
---|---
PART NUMBERS
CT-CON-0150EZ-U
CT-CON-0150EZ-B| Crimp ferrules on leads
With Banana Plugs (for use with Legacy Weather-tight PRO-Series Instruments)
---|---
CONTACT US
DENT Instruments, Inc.
Energy & Power Measurement Solutions
925 SW Emkay Dr
Bend, Oregon 97702 USA
541.388.4774 | 800.388.0770
www.DENTinstruments.com
All specifications contained in this document are
subject to change without notice.
© DENT INSTRUMENTS, INC.
rev 102814