PENTAIR KS-JP50000 Dirt Water Pump Basement Drainage Pump Instruction Manual
- June 12, 2024
- Pentair
Table of Contents
KS-JP50000 Dirt Water Pump Basement Drainage Pump U3
U3 K Spezial
U3 KS Spezial
Instruction Manualwww.tuv.com
ID 1111219532
KS-JP50000 Dirt Water Pump Basement Drainage Pump
Installation GR 32
Installation example
40 x 40 mm / Ø 50 cm 50 x 50 mm / Ø 50 cm
You have purchased a product made by Pentair Jung Pumpen and with it,
therefore, also excellent quality and service. Secure this service by carrying
out the installation works in accordance with the instructions, so that our
product can perform its task to your complete satisfaction. Please remember
that damage caused by incorrect installation or handling will adversely affect
the guarantee. Therefore please adhere to the instructions in this manual!
This appliance can be used by children aged 8 years or over and by persons
with limited physical, sensory or intellectual capabilities, or with limited
experience and knowledge, provided that they are supervised or have been
instructed in the safe use of the appliance and are aware of the dangers
involved. Children must not be allowed to play with the appliance. Cleaning
and user maintenance must not be carried out by children unless they are
supervised.
Damage prevention in case of failure
Like any other electrical device, this product may fail due to a lack of mains
voltage or a technical defect.
If damage (including consequential damage) can occur as a result of product
failure, the following precautions can be taken at your discretion:
- Installation of a water level dependent (under circumstances, mains-independent) alarm system, so that the alarm can be heard before damage occurs.
- Inspection of the collecting tank/chamber for tightness up to the top edge before – or at the latest, during – installation or operation of the product.
- Installation of backflow protection for drainage units that can be damaged by wastewater leakage upon product failure.
- Installation of a further product that can compensate in case of failure of the other product (e.g. duplex unit).
- Installation of an emergency power generator.
As these precautions serve to prevent or minimize consequential damage upon product failure, they are to be strictly observed as the manufacturer’s guideline – in line with the standard DIN EN specifications as state of the art – when using the product (Higher Regional Court Frankfurt/Main, Ref.: 2 U 205/11, 06/15/2012).
SAFETY INSTRUCTIONS
This instruction manual contains essential information that must be observed
during installation, operation and servicing. It is therefore important that
the installer and the responsible technician/operator read this instruction
manual before the equipment is installed and put into operation. The manual
must always be available at the location where the pump or the plant is
installed.
Failure to observe the safety instructions can lead to the loss of all
indemnity.
In this instruction manual, safety information is distinctly labelled with
particular symbols. Disregarding this information can be dangerous.
General danger to people
Warning of electrical voltage
NOTICE! Danger to equipment and operation
Qualification and training of personnel
All personnel involved with the operation, servicing, inspection and
installation of the equipment must be suitably qualified for this work and
must have studied the instruction manual in depth to ensure that they are
sufficiently conversant with its contents. The supervision, competence and
areas of responsibility of the personnel must be precisely regulated by the
operator. If the personnel do not have the necessary skills, they must be
instructed and trained accordingly.
Safety-conscious working
The safety instructions in this instruction manual, the existing national
regulations regarding accident prevention, and any internal working, operating
and safety regulations must be adhered to.
Safety instructions for the operator/user
All legal regulations, local directives and safety regulations must be
adhered to. The possibility of danger due to electrical energy must be
prevented.
Leakages of dangerous (e.g. explosive, toxic, hot) substances must be
discharged such that no danger to people or the environment occurs. Legal
regulations must be observed.
Safety instructions for installation, inspection and maintenance works
As a basic principle, works may only be carried out to the equipment when it
is shut down. Pumps or plant that convey harmful substances must be
decontaminated.
All safety and protection components must be re-fitted and/or made operational
immediately after the works have been completed. Their effectiveness must be
checked before restarting, taking into account the current regulations and
stipulations.
Unauthorized modifications, manufacture of spare parts
The equipment may only be modified or altered in agreement with the
manufacturer. The use of original spare parts and accessories approved by the
manufacturer is important for safety reasons. The use of other parts can
result in liability for consequential damage being rescinded.
Unauthorized operating methods
The operational safety of the supplied equipment is only guaranteed if the
equipment is used for its intended purpose. The limiting values given in the
“Technical Data” section may not be exceeded under any circumstances.
Instructions regarding accident prevention
Before commencing servicing or maintenance works, cordon off the working area
and check that the lifting gear is in perfect condition.
Never work alone. Always wear a hard hat, safety glasses and safety shoes and,
if necessary, a suitable safety belt.
Before carrying out welding works or using electrical devices, check to ensure
there is no danger of explosion.
People working in wastewater systems must be vaccinated against the pathogens
that may be found there. For the sake of your health, be sure to pay
meticulous attention to cleanliness wherever you are working.
Make sure that there are no toxic gases in the working area.
Observe the health and safety at work regulations and make sure that a first-
aid kit is to hand.
In some cases, the pump and the pumping medium may be hot and could cause
burns.
For installations in areas subject to explosion hazards, special regulations
apply!
APPLICATION
WARNING!
The pump must only be connected to sockets that have been installed properly
in accordance with the regulations and are protected with at least 10 A (slow)
and RCD-safety switches (30mA).
DANGER!
The pump must never be used when a person is in the water.
Submersible pumps from the U3 and U3 Spezial series are suitable for pumping
domestic waste water without stones. This includes also water from household
dishwashers and household washing machines.
The U3 Spezial can also pump aqueous solutions with up to 15% salt content and
condensate from gas condensing boilers.
NOTICE! In outdoor applications, only pumps with at least a 10-metre
mains cable must be used.
When using the pumps, the relevant national laws, regulations and stipulations
must be adhered to, for example:
- Domestic contaminated and waste water (e.g. EN 12056 in Europe)
- Installation of low voltage systems (e.g., VDE 0100 in Germany)
For non-standard utilization conditions, further regulations must be observed
(e.g. VDE 0100 in Germany, part 701: bathrooms and shower rooms; part 702:
swimming pools and fountains and part 737: outdoor use).
Temperatures
The pumped medium must have a temperature of max 35 °C. For a short time 60 °C
are permissible (S2: 10 min, S3: 30%).
CAUTION!
Scalding by hot water – risk of injury!
The submersible pump is frost-resistant down to -20 °C when stored in dry
conditions. When installed, however, it must not be allowed to freeze in the
water.
Transport
The pump must always be lifted by the handle and never by the power supply
cable! The pump should only be lowered into deeper chambers or pits using a
rope or chain.
ELECTRICAL CONNECTION
NOTICE! Only qualified electricians may carry out electrical works to the
pump or the controls.
WARNING!
Before carrying out any works: disconnect the pump and the controls from the
mains and take steps to ensure that no one else can reconnect them to the
power supply.
The relevant standards (such as EN standards), country-specific regulations
(such as VDE in Germany), and the regulations of the local power supply
companies must be observed.
NOTICE! Never put the mains plug or a free lead end in water!
If water gets into the plug, this can cause malfunctions and damage.
Observe the operating voltage (see the type plate)!
The pump is provided with a winding thermostat. In case of unacceptably high
temperatures it switches off the pump to protect it against possible damage.
Unacceptably high temperatures may result e.g. from dry running or mechanical
or electrical overload.
CAUTION!
The pump is switched on again automatically after cooling down – risk of
injury!
For this reason, always disconnect the device from the mains before remedying
the fault! In order to do this, unplug from the mains supply or remove the
pre-fuses of the pump controls!
INSTALLATION
The pump must be installed as shown in the examples. For installations in
accordance with EN 12056-4, the pressure pipe must be laid in a loop above the
local backflow level and protected with a backflow prevention valve in
accordance with EN 12050-4.
A correspondingly larger diameter pipe should be used for longer pressure
pipelines to avoid pipe friction losses.
With any pump that has no automatic switching, the switch-on and switch-off
heights can be set variably with a separate level control. Our ready to
connect level controls can be installed without specific electrotechnical
skills.
The pump housing is automatically vented via the enclosed 90° elbow. If this
is not desired, the ventilation opening can be closed, e.g. for mobile
operation. Flushing device
The pump can keep the intake section at the bottom of the chamber clear of
deposits to a large extent if you carry out a small modification: Lever off
the foot strainer with a screwdriver, unscrew the three red caps and snap the
foot strainer back on. This reduces the performance of the pump only
insignificantly. Low level pumping
Flooded surfaces can be drained down to a residual water level of a few mm
without using any special accessories. To do so, the foot strainer must be
levered off with a screwdriver. In the case of pumps with an attached control,
the float switch must be locked in the ON position. It is not possible
therefore in low level pumping to operate the pump in switching mode.
To make the pump operate, the drainage hose must be emptied before each
pumping run and there must be a 40mm minimum water level available.
NOTICE! If the pump is malfunctioning, part of the contents of the oil
reservoir could escape into the pumping medium.
NOTICE! The floats of the level controller and alarm system (accessory)
are installed so that they are freely movable but not under the inlet. Please
observe the minimum distances, see installation example. The controls may only
be installed in a dry and well ventilated room!
CAUTION!
For safety reasons, mobile operation is only allowed vertically and with a
foot strainer!
If a hose is used as a pressure line, care must be taken to ensure that for
every pumping operation the hose is completely empty before the pump is
submersed. Any residual liquid would obstruct the ventilation of the pump
housing and therefore also hinder the pumping operation. For the same reason,
the pump would not operate if it was switched on before being submersed.
CLEANING
WARNING!
Before carrying out any works: disconnect the pump and the controls from the
mains and take steps to ensure that no one else can reconnect them to the
power supply.
WARNING!
Check the mains cable for signs of mechanical and chemical damage. Damaged or
kinked cables must be replaced by the manufacturer.
NOTICE! If the water contains high levels of iron or lime, insufficient
cleaning can result in irreparable damage to the seal and thus also to the
pump motor in the long term. Consequently, the pump must be cleaned at regular
intervals according to the hardness of the water.
Tightening torque MA for A2 screw materials
for M 5 | MA = 5 Nm |
---|---|
for Amtec 3 | MA = 0,7 Nm |
for Amtec 5 | MA = 2 Nm |
QUICK TIPS FOR REMEDYING FAULTS
Pump does not work
- Check mains current (do not use a pin gauge)
- Fuse faulty = may be too weak (please refer to Electrical Connection)
- Mains supply cable damaged = repair to be carried out by manufacturer only
Pump runs but does not pump
- Empty the pressure pipe or hose to allow the non-return valve to open and the air to escape from the pump housing, it may be necessary to carry out a ventilation drilling
Impeller blocked
- Solids and fibrous matter have become lodged in the pump housing = clean
Decreased pumping performance
- Foot strainer obstructed = clean
- Pressure pipe obstructed = clean
- Rotor worn out = repair to be carried out by the manufacturer
****0197
JUNG PUMPEN GmbH – Industriestraße. 4-6
33803 Steinhagen, Germany 20
401.17-22.02
EN 12050-2:2001; 2015
Lifting plant for faecal-free wastewater DN 32
U3 K (JP50002)
U3 KS (JP50000)
U3 KS (JP50001)| U3 K spez. (JP50007)
U3 KS spez. (JP50005)
U3 KS spez. (JP50006)
Collecting and automatically lifting faecal-free waste water above the
backflow level in buildings and sites
REACTION TO FIRE| NPD
---|---
WATERTIGHTNESS| Pass
EFFECTIVENESS (LIFTING EFFECT
– Pumping of solids
– Pipe connections
– Ventilation
– Minimum flow velocity
– Minimum free passage of the plant – Minimum useful volume| Pass
Pass
NPD
Pass
Pass
NPD
MECHANICAL RESISTANCE
– Load bearing capacity and structural stability of collection tank for use
– Structural stability of collection tank for use inside buildings| NPD
NPD
NOISE LEVEL| 70 dB(A)
DURABILITY
– of structural stability
– of lifting effectiveness
– of mechanical resistance| NPD Pass NPD
DANGEROUS SUBSTANCES| NPD
TECHNICAL DATA
| | U3 KS, 4m
U3 KS spezial, 4m| U3 KS, 10m
U3 KS spezial, 10m| U3 K. 10m
U3 K spezial, 10m
---|---|---|---|---
| [kg]| 3,5| 4,4| 3,8
| DN| 32| 32| 32
[mm]| 10| 10| 10
S1| 35°C| | |
S2| 60 °C| 10 min| 10 min| 10 min
S3| 60 °C| 30%| 30%| 30%
P1| [W]| 320| 320| 320
P2| [W]| 220| 220| 220
U| [V]| 1/N/PE -230| 1/N/PE -230| 1/N/PE -230
f| [Hz]| 50| 50| 50
I| [A]| 1,4| 1,4| 1,4
Performance
Declaration of Conformity
Directives – Harmonised standards
• 2006/42/EG
• 2011/65/EU
• 2014/30/EU| (MD)
(RoHS)
(EMC)| EN 809:1998/AC:2010, EN ISO 12100:2010, EN 60335- :2012/A13:2017
EN55014-1:2017/A11:2020, EN 55014-2:1997/A2:2008, 60034- 1AC:2010
EN 61000-3-2:2014, EN 61000-3-3:2013
---|---|---
JUNG PUMPEN GmbH – Industriestr.
4-6 – 33803 Steinhagen – Germany
www.jung-pumpen.de
We hereby declare, under our sole responsibility, that the product is in accordance with the specified Directives.
U 3 K (JP50002/3)
U 3 KS (JP50000/3)
U 3 KS (JP50001/3)
U 3 K SPEZ. (JP50007/3)
U 3 KS SPEZ. (JP50005/3)
U 3 KS SPEZ. (JP50006/3)
UV3 (JP50248)| UV3 S (JP50249)
UV3 S (JP50312)
UV3 SF (JP50313)
U 5 K (JP09386)
U 5 KS (JP09387)
U 5 KS (JP09417)
U 6 K E (JP00226/2)| U 6 K D (JP00228/3)
U 6 K ES (JP00227/2)
U 6 K ES (JP09260/2)
U 6 K DS (JP00229/3)
U 6 K DS (JP09261/3)
UB 62 ES (JP09818/3)| UB 62 DS (JP09819/2)
UB 102 ES (JP09283/0)
UB 102 DS (JP00534/8)
UB 152 ES (JP09439/0)
UB 152 DS (JP09440/0)
UB 251 DS (JP09298/1)
J 67 ET (JP09153/1)
---|---|---|---
Other normative documents
EN 60335-2-41:2003/A2:2010 VDE GS 40054271 (U3/3, UV3) EMC-VDE 40052857
(U3/3, UV3)
VDE GS 40020521 (U3/2, U5)
EMC-VDE 40020827 (U5)
VDE GS 40020499 (U6K D/3)
VDE GS 40020502 (U6K E/2)| EN 62233:2008/AC:2008
EMC-VDE 92272 (U6 E/D/1)
VDE GS 40018339 (US UB 62 105 D)
EMC-VDE 138689 (US UB 62_105 D)
VDE 40035932 (US UB 62_105 E)
EMC-VDE 129830 (US UB 62 105 E)
---|---
Authorized person for technical documentation
JUNG PUMPEN – Stefan Sirges – Industriestr. 4-6 – 33803 Steinhagen
Steinhagen, 01-02-2022
|
---|---
Stefan Sirges, General Manager
|
Pascal Kölkebeck, Sales Manager
Jung Pumpen GmbH
Industriestr. 4-6
33803 Steinhagen
Deutschland
Tel. +49 5204 170
kd@jung-pumpen.de| Pentair Water Italy Srl
Via Masaccio, 13
56010 Lugnano – Pisa
Italia
Tel. +39 050 716 111
info@jung-pumpen.it| Pentair Water Polska Sp.
z o.o.ul.
Plonów 21
41-200 Sosnowiec
Polska
Tel. +48 32 295 1200
infopl.jungpumpen@pentair.com
---|---|---
All indicated Pentair trademarks and logos are property of Pentair.
Third party registered and unregistered trademarks and logos are the property
of their respective owners.
© 2020 Pentair Jung Pumpen
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>