Qlima MS-AC 5001 Split Unit Air Conditioner User Manual

June 12, 2024
Qlima

Qlima MS-AC 5001 Split Unit Air Conditioner Qlima MS-AC 5001 Split Unit Air Conditioner

Qlima MS-AC 5001 Split Unit Air Conditioner

IMPORTANT COMPONENTS

Important Components
Important Components

  1. Hose
  2. Handle
  3. Control panel
  4. Outdoor unit air outlet
  5. Indoor unit air outlet
  6. Indoor unit air inlet
  7. Outdoor unit air outlet

WHAT’S INCLUDED

What's Included

  1. Outside bracket
  2. M6 Screw
  3. Gasket of M6 screw
  4. Protection sleeve
  5. Drain hose
  6. Shockproof rubber dampers
  7. Inside bracket
  8. Hand screw

Dear Sir, Madam,

Congratulations on the purchase of your air conditioner. You have acquired a high quality product that will provide you with many years of pleasure, on condition that you use it responsibly. Reading these instructions for use before operating your air conditioner will optimise its life span. We wish you comfort with your air conditioner.

Yours sincerely,
PVG Holding B.V.
Customer service department

SAFETY INSTRUCTIONS

Read this user manual carefully before using the appliance and keep it for future reference. Install this device only when it complies with local/national legislation, ordinances and standards. This product is intended to be used as an air conditioner in residential houses and is only suitable for use in dry locations, in a caravan, in normal household conditions, indoors in living room, kitchen and garage.

IMPORTANT

  • Never use the device with a damaged power cord, plug, cabinet or control panel. Never trap the power cord or allow it to come into contact with sharp edges.
  • The installation must be completely in accordance with local regulations, ordinances and standards.
  • The device is suitable exclusively for use in dry places, indoors.
  • Check the mains voltage. This device is suitable exclusively for earthed sockets – connection voltage 220-240 Volt/ 50 Hz.
  • The device MUST always have an earthed connection. You may absolutely not connect the device if the power supply is not earthed.
  • The plug must always be easily accessible when the device is connected.
  • Read these instructions carefully and follow the directions.

Before connecting the device, check that:

  • The connection voltage corresponds to that on the type plate.
  • The socket and power supply are suitable for the device.
  • The plug on the cable fits the socket.
  • The device is on a stable and flat surface.

Have the electrical installation checked by a recognised expert if you are not sure that everything is in order.

  • The air-conditioned is a safe device, manufactured in accordance with CE safety standards. Nevertheless, as with every electrical device, exercise caution when using it.
  • Never cover the air inlets and outlets.
  • Empty the water reservoir through the water drain before moving it.
  • Never allow the device to come into con- tact with chemicals.
  • Do not insert objects into the openings of the device.
  • Never allow the device to come into con- tact with water. Do not spray the device with water or submerge it as this may cause a short circuit.
  • Always take the plug out of the socket before cleaning or replacing the device or a part of the device.
  • NEVER connect the device with the aid of an extension cable. If a suitable, earthed socket is not available, have one fitted by a recognised electrician.
  • Always consider the safety of children in the vicinity of this device, as with every electrical device
  • Always have any repairs – beyond regular maintenance – carried out by a recognised service engineer. Failure to do so may lead to invalidation of the guarantee.
  • Always take the plug out of the socket when the device is not in use.
  • If the power cable is damaged it must be replaced by the manufacturer, its customer service department or persons with com- parable qualifications in order to prevent danger.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be made by children without supervision.

ATTENTION!

  • Never seal the room – where this device will be used – completely airtight. This will prevent under pressure in this room. Under pressure can disrupt the safe operation of geysers, ventilation systems, ovens, etc.
  • Failing to follow the instructions may lead to nullification of the guarantee on this device.

Specific information regarding appliances with R290 refrigerant gas.

Thoroughly read all of the warnings.

  • When defrosting and cleaning the appliance, do not use any tools other than those recommended by the manufacturing company.
  • The appliance must be placed in an area without any continuously sources of ignition (for example: open flames, gas or electrical appliances in operation).
  • Do not puncture and do not burn.
  • This appliance contains X g of R290 refrigerant gas.
  • R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the refrigerant circuit. Be aware the refrigerants may not contain an odour.
  • If the appliance is installed, operated or stored in a nonventilated area, the room must be designed to prevent to the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters, stoves, or other sources of ignition.
  • The appliance must be stored in such a way as to prevent mechanical failure.
  • Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in the industry.
  • Repairs must be performed based on the recommendation from the manufacturing company.

Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of an individual specified in the use of flammable refrigerants.

Appliances shall be installed, operated and stored in a room with a floor area larger than 4 m2. The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.

INSTRUCTIONS FOR REPAIRING APPLIANCES CONTAINING R290

GENERAL INSTRUCTIONS

This instruction manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic, refrigerant and mechanical experience.

  1. Checks to the area
    Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

  2. Work procedure
    Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed.

  3. General work area
    All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided.
    The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

  4. Checking for presence of refrigerant
    The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non sparking, adequately sealed or intrinsically safe.

  5. Presence of fire extinguisher
    lf any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

  6. No ignition sources
    No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

  7. Ventilated area
    Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it extremally into the atmosphere.

  8. Checks to the refrigeration equipment
    Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. lf in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants: – the charge size is in accordance with the room size within which the refrigerant containing parts are installed;
    • the ventilation machinery and outlets are operating adequately and are not obstructed;
    • if an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    • marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    • refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or are suitably protected against being so corroded.

  9. Checks to electrical devices
    Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. lf a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. lf the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised. initial safety checks shall include:
    • that capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
    • that there no live electrical components and wiring are exposed while charging, recovering or purging the system;
    • that there is continuity of earth bonding.

REPAIRS TO SEALED COMPONENTS

  1. During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. lf it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
  2. Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc.
    Ensure that apparatus is mounted securely.
    Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres.
    Replacement parts shall be in accordance with the manufacturer’s specifications.
    NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. intrinsically safe components do not have to be isolated prior to working on them

REPAIR TO INTRINSICALLY SAFE COMPONENTS

Do not apply any permanent inductive or capacitance loads to the circuit without ensuring that this will not exceed the permissible voltage and current permitted tor the equipment in use.

intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.

Replace components only with parts specified by the manufacturer. Other parts may result in the ignition of refrigerant in the atmosphere from a leak.

CABLING

Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the effects of aging or continua! vibration from sources such as compressors or fans.

DETECTION OF FLAMMABLE REFRIGERANTS

Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame} shall not be used.

LEAK DETECTION METHODS

The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need recalibration. (Detection equipment shall be calibrated in a refrigerant- free area.)
Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25 % maximum} is confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipework.
lf a leak is suspected, all open flames shall be removed/extinguished.
lf a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves} in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.

REMOVAL AND EVACUATION

When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. The following procedure shall be adhered to: remove refrigerant; purge the circuit with inert gas; evacuate; purge again with inert gas; open the circuit by cutting or brazing.
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be “flushed” with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system.
When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipework are to take place. Ensure that the outlet tor the vacuum pump is not close to any ignition sources and !here is ventilation available.

CHARGING PROCEDURES

In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. Label the system when charging is complete (if not already). Extreme care shall be taken not to overfill the refrigeration system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow up leak test shall be carried out prior to leaving the site.

DECOMMISSIONING

Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. lt is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. lt is essential that 4 GB electrical power is available before the task is commenced.

a) Become familiar with the equipment and its operation.
b) lsolate system electrically.
c) Before attempting the procedure ensure that: mechanical handling equipment is available, if required, for handling refrigerant cylinders;
d) All personal protective equipment is available and being used correctly; the recovery process is supervised at all times by a competent person; e) recovery equipment and cylinders conform to the appropriate standards.
f) Pump down refrigerant system, if possible. g) lf a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system. h) Make sure that cylinder is situated on the scales before recovery takes place.
i) Start the recovery machine and operate in accordance with manufacturer’s instructions.
j) Do not overfill cylinders. (No more than 80 % volume liquid charge).
k) Do not exceed the maximum working pressure of the cylinder, even temporarily.
l) When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. m) Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.

LABELLING

Equipment shall be labelled stating that it has been de-commissioned and emptied of refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant.

RECOVERY

When removing refrigerant from a system, either for servicing or decommissioning, il is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants. In addition, a set of calibrated weighing scales shall be available and in good working order. Hoses shall be complete with leak-free disconnect couplings and in good condition. Before using the recovery machine, check that il is in satisfactory working order, has been properly maintained and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders. lf compressors or compressor oils are to be removed, ensure that they have been evacuated to an acceptable level to make certain that flammable refrigerant does not remain within the lubricant. The evacuation process shall be carried out prior to returning the compressor to the suppliers. Only electric healing to the compressor body shall be employed to accelerate this process. When oil is drained from a system, il shall be carried out safely.

INSTALLATION OF THE AIR CONDITIONER

  1. Unpack the machine and accessories and check that the hose between the indoor and outdoor unit is properly connected. Also check whether the condensation drain has a rubber cover. Finally, check whether the accessories are complete.
  2. 1 Install the accessories as shown in the picture. Connect the outer bracket to the support block and the inner bracket by tightening the M6 screws. This is how you form the carrying handle.

2.2 Place the shockproof rubber dampers on the back of the outdoor unit.
Installation Of The Air Conditioner
2.3 Install the bracket as shown in the figure below. Install the indoor and outdoor units on the bracket to fix the two parts. To secure the units to the bracket, tighten the M6 screws in the appropriate holes.
Installation Of The Air Conditioner
2.4 Install the indoor unit on the bracket and tighten the bracket properly. Next, wrap the protection sleeve on the hose between the outdoor and indoor unit.(See the illustration below )
Installation Of The Air Conditioner
2.5 Install the complete unit in the caravan window and tighten the bracket properly.
Installation Of The Air Conditioner

OPERATION OF CONTROL PANEL

Operation Of Control Panel

  1. Power
    Press this key to turn the device on and off.
    When the air conditioner is switched on, the temperature is set to 22ºC by default. The temperature sensor measures the ambient temperature and if exceeds 22ºC, the outdoor unit starts to work to bring the temperature down. If the ambient temperature already below 22ºC, then the outdoor unit does not start.

  2. Mode
    Press this key to select cooling, fan, dehumidification modes;
    In standby/turned on mode, by pressing this key for 3 seconds to set timing on/ off.

  3. Temperature / time adjustment
    In cooling mode, press the key to increase or decrease the temperature, the setting temperature adjustable from 16~30ºC; In timer mode, press the key to adjust time to turn on/turn off the machine.
    Press Up/Down key at the same time to transfer between ºC and ºF.

  4. Fan speed
    Press the key to choose low/high fan speed.

  5. Sleep mode
    Press the key to enter or quit sleep mode. After 20 seconds, all lights and the digital display turn off and the air conditioner goes to sleep. The indoor unit fan continues to run at low fan speed.

  6. Display window
    Check temperature and time from this window.

  7. Swing
    Press fan speed and sleep mode key at the same time to turn on/off swing function.

MAINTENANCE

DECLARATION:

  1. Ensure the machine is unplugged before maintenance.
  2. Do not use gasoline or other chemicals to clean the unit;
  3. Do not wash the unit directly;
  4. If the air conditioner is damaged, please contact the dealer or repair shop.

CLEANING

CAUTION: Unplug the power cord before cleaning the maintenance.

  1. AIR FILTER
    • It is important to regularly remove the dust from the filter.
    • Remove the filter as shown in the picture below.
    • Clean the filter with tap water and / or a vacuum cleaner to remove any dirty from the filter.
    • Do not use water hotter than 40°C for cleaning and do not expose the filter to the sun.
    • Make sure the filter has dried before putting it back in the air conditioner.
    Maintenance

  2. CLEAN THE AIR-CONDITIONER SURFACE
    • First clean the surface with a neutral detergent and wet cloth;
    • Then dry the device thoroughly with a dry cloth.
    • Do not allow water or deterrent to enter the machine.
    • Do not clean the air conditioner with an aggressive cleaning agent and/or petrol.

STORAGE

If you are planning to store the machine without needing to use it for a long time, please remove the drain cover from the drainage hole at the bottoms both of indoor unit and outdoor unit, and drain all the condensation water appropriately in available place.

Maintenance

  1. Remove the unit from the window.
  2. Remove the rubber seal from the indoor unit and outdoor unit, drain the condensate water.
  3. Keep running in fan mode to make the internal dry.
  4. Turn off the conditioner and pull down the plug.
  5. Wash the filter then install.
  6. Remove all the brackets on the air conditioner, install the brackets of the indoor unit on the outdoor unit, assemble as shown in the figure below, and then store the unit against the wall.
  7. Store the air conditioner in a cool and dry place.
  8. We recommend that you put the air conditioner back in its packaging when you store it. This prevents dirt and dust from collecting on the air conditioner.
    Maintenance

WIFI SETUP AND SMART FEATURES

WIFI SETUP

BEFORE YOU START

  • Ensure your router provides a standard 2.4ghz connection.
  • If your router is dual band ensure that both networks have different network names (SSID). The provider of your router / Internet service provider will be able to provide advice specific to your router.
  • Place the air conditioner as close as possible to the router during setup.
  • Once the app has been installed on your phone, turn off the data connection, and ensure your phone is connected to your router via wifi.

DOWNLOAD THE APP TO YOUR PHONE

  • Download the ”SMART LIFE” app, from your chosen app store, using the QR codes below, or by searching for the app in your chosen store.

|
---|---

Android

|

IOS

CONNECTION METHODS AVAILABLE FOR SETUP

  • The air conditioner has two different setup modes, Quick Connection and AP (Access Point). The quick connection is a quick and simple way to set the unit up. The AP connection uses a direct local wifi connection between your phone and the air conditioner to upload the network details.
  • In Standby mode press and hold the fan button for 3 seconds (until you hear a bleep) to enter the wifi connection mode.
  • Please ensure your device is in the correct wifi connection mode for the connection type you are attempting, the flashing of the wifi light on your air conditioner will indicate this.
Connection Type Frequency of Flashes Frequency of Flashes
Quick Connection Flashes twice per second
AP (Access Point) Flashes once per three seconds

CHANGING BETWEEN CONNECTION TYPES

To change the unit between the two wifi connection modes, hold the fan button for 3 seconds.

DOWNLOAD Icon| QR
Code
---|---
WIFI MANUAL

TROUBLE SHOOTING GUIDE

Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here.

Problem Reasons Solution
The device does not turn on. No power. Turn power on.
Damaged electrical outlet. Turn off the power and check/repair the power

outlet.
Unknown reason.| Contact the dealer.
Little air displacement or limited cooling effect.| The lowest ventilation setting is selected.| Select the high ventilation speed mode.
The air filter is dirty.| Check and clean the filter.
The air supply or exhaust of the indoor unit is blocked.| Check that the unit is not blocked and remove the obstruction.
The air supply or exhaust from the outdoor unit is blocked.| Check that the unit is not blocked and remove the obstruction.
The ambient temperature is too low or high.| The ambient temperature must be between 18 and 40ºC.
Insufficient voltage from the power supply.| Consult an installer or use a different power connection.
Air displacement only but no cooling effect.| The device runs in ventilation mode.| Select the cooling mode (A/C).
The cooling mode has just turned off automatically.| Wait about 3-5 minutes until the thermostat switches on again.
Abnormal sounds or vibrations.| The mounting brackets are not properly installed on the vehicle, or the device mounting screws are not sufficiently tightened.| Check that the mounting bracket is tight and tighten the device mounting screws.
Water is leaking from the indoor unit.| The rubber stopper on the bottom of the indoor unit is missing, or is not pressed enough.| Check or replace the rubber stopper.
The device is at an angle| The device must be mounted horizontally (maximum angle <3°C.
The appliance emits a related odor.| There is a serious problem.| Switch off the device immediately and contact the dealer.

If problems not listed in the table occur or recommended solutions do not work, please contact the service centre.

ERROR CODE LIST

If the device does not work or works insufficiently:
Check if an error code is visible in the display, refer to the code table for a solution. If no error code is visible in the display, go through the error table for a possible solution.

Error code Cause Solution
FL Water full alarm Contact the dealer
E1 System temperature sensor fault
E2 Room temperature sensor fault
EF Indoor motor fault
Eb Lack of fluorine
E4 Freeze protection

GUARANTEE CONDITIONS

The air conditioner is supplied with a 24-month guarantee, commencing on the date of purchase. All material and manufacturing defects will be repaired or replaced free of charge within this period. The following rules apply:

  1. We expressly refuse all further damage claims, including claims for collateral damage.
  2. Repairs to or replacement of components within the guarantee period will not result in an extension of the guarantee.
  3. The guarantee is invalidated if any modifications have been made, non genuine parts are fitted or repairs are carried out by third parties.
  4. Components subject to normal wear, such as the filter, are not covered by the guarantee.
  5. The guarantee is valid only when you present the original, dated purchase invoice and if no modifications have been made to the product nor to the purchase invoice.
  6. The guarantee is invalid for damage caused by neglect or by actions that deviate from those in this instruction booklet.
  7. Transportation costs and the risks involved during the transportation of the air conditioner or air conditioner components shall always be for the account of the purchaser.
  8. Damage caused by not using suitable filters is not covered by the guarantee.

To prevent unnecessary expense, we recommend that you always first carefully consult the instructions for use. Take the air conditioner to your dealer for repairs if these instructions do not provide a solution.

Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. Do not throw batteries into the fire, where they can explode or release dangerous liquids. If you replace or destroy the remote control, remove the batteries and throw them away in accordance with the applicable regulations because they are harmful to the environment.

Environmental information: This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It should only be serviced or dismantled by professional trained personnel.

This equipment contains R290 refrigerant in the amount as stated in the table above. Do not vent R290 into atmosphere: R290, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 3.

Symbol

Distributed in Europe by PVG Holding B.V.

If you need information or if you have a problem, please visit the our website (www.qlima.com) or contact our sales support (T: +31 412 694 694).

Symbol

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals