AIPHONE IPW-10VC Analog to IP Converter kit
The IPW-10VC is an analog-to-IP converter kit that uses 2-conductor copper wire to connect IP intercom stations. The kit includes one IPW-10VR rack-mount receiver module and ten IPW-1VT transmitter modules.
Features
- Works with existing 2-conductor copper wire
- Provide PoE to door stations up to 1000 feet away
- Connects up to ten door stations with a single network port
- Rack mountable
- LED status indicators
Package Contents
-
IPW-10VR Rack Mount Receiver Module
-
4 M5 Screws
-
10 IPW-1VT Transmitter Modules
-
20 2-wire to RJ45 converters
-
Outlet Plug
Installation and Configuration
The IPW-10VR is configured out of the box to provide power and network connection on all ten of the PoU (Power over UTP wire) ports.
For each station connected to the IPW-10VC, use two of the 2-wire to RJ45 converters. One will plug into a port on the IPW-10VR, and the other will go into the IPW-1VT transmitter module. Use a small Phillips-head screwdriver to loosen and tighten the converters to connect the 2-conductor wires to both sides.
The four provided screws allow the IPW-10VR receiver module to be installed in a 1U server rack space.
The IPW-10VR is powered from a wall outlet, and is connected to the network by one of the two ethernet ports
Sample Wiring Diagram
Web Interface Instructions
The IPW-10VR features a web interface that can be used to adjust its network settings, change the log in credentials, restart, or factory reset the station. The network and security settings may not need to be adjusted on all sites, since the IPW-10VC kit can work on an isolated network. Consult on-site IT about networking requirements.
The default settings are already properly configured to power and connect A iphone stations, so this guide does not cover adjusting the power settings
Accessing the Web Interface
The IPW-10VR’s default IP address is 192.168.1.200. Set the programming PC’s IP address to be in the same range and enter 192.168.1.200 in the web browser. A log in page will appear. The default user name and password are admin. Once those are entered, the following home screen will be displayed. Navigate to System Configuration, Network Configuration.
Changing Network Settings
Navigate to System Configuration, Network Configuration. Configure the
network settings and click**Save**
.
It is not necessary or advisable to change the power settings under System Configuration, PoU Configuration.
Changing the User Name and Password
Navigate to System Configuration, User. Enter the desired login
credentials and click Save
.
Restarting the Station
Navigate to Maintenance, Restart Device. Click Yes
.
Factory Resetting the Station
Navigate to Maintenance, Factory Defaults. Enter the desired login
credentials and click Save
.
Specifications
Power Input: | 100-240V AC |
---|---|
Power Draw: | 260W max |
Mounting: | Supplied 1U rack mount |
LAN Ports: | 2 (RJ45) |
UTP Ports: | 10 (RJ45 to UTP connector) w |
Cat-5e/6 to 2-wire Converter: | 15 feet |
Calling Capacity: w/Video Station | 0-500 feet 5 master stations |
w/Video Station | 501-1000 feet 3 master stations |
w/Audio Station | 0-1000 feet 7 master stations |
Operation Temp: | -4°~158°F (-20°~70°C) |
Dimensions: | 1-3/4″ H x 19″ W x 11″ D |
FCC WARNING
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation.
For proper regulatory compliance, the drain wire should be disconnected at the
power supply end of the cable.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
CUSTOMERSSUPPORT
For more details about the features and information above, please contact
Technical Support.
06/23 Aiphone Corporation | www.aiphone.com |
800-692-0200
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>