ATTENTION!
Read all safety rules carefully before attempting to operate. Retain for future reference.
DANGER!
Never operate this unit when flammable materials or vapors are present because electrical devices produce arcs or sparks that can cause a fire or explosion. NEVER OPERATE UNATTENDED!
For your records, please record the following information and store this user manual in a safe location.
Catalog No…………………………… (Located on the carton)
Model No…………………………….. (Located on the unit)
Purchase Date:………………………..
TOOLS NEEDED

  • Safety Glasses

IMPORTANT SAFETY INSTRUCTIONS

When using an electric appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:

  1. Do not leave the appliance when plugged in. Unplug from outlet when not in use and before servicing. Connect to a properly grounded outlet only. See Grounding Instructions.
  2. Do not expose to water or rain – store indoors.
  3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  4. Use only as described in this manual. Use only the manufacturer’s recommended attachments.
  5. Do not operate Air Mover with a damaged cord or plug. Discard Air Mover or return to Shop-Vac for examination and/or repair. If the appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, contact Shop-Vac for assistance.
  6. Do Not: pull or carry by cord, use cord as a handle, close door on cord or pull cord around sharp edges or corners. Do not run appliance over cord. Keep the cord away from heated surfaces.
  7. Do not unplug by pulling on the cord. To unplug, grasp the plug; not the cord.
  8. Do not handle the plug or appliance with wet hands.
  9. Do not put any object into openings. Do not use any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow.
  10. Keep hair, loose clothing, fingers, and all parts of the body away from openings and moving parts.
  11. Turn off all controls before unplugging.
  12. WARNING! To avoid injury or property damage: do not use explosive liquids or vapors, as electrical devices produce arcs or sparks, which can cause a fire or explosion.
  13. Do not store or use near flammable or combustible liquids such as gasoline, toxic, carcinogenic, combustible, or hazardous materials such as asbestos, arsenic, barium, beryllium, lead, pesticides, or other health-endangering materials.
  14. Do not run cord under carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Arrange the cord away from the traffic area so that it will not be tripped over.
  15. Operation of this unit can result in foreign objects being blown into the eyes, which can result in eye damage. Always wear safety goggles when operating Air Mover.
  16. STAY ALERT , Watch what you are doing and use common sense.
  17. Use only GFCI Protected Receptacles.
  18. Do not use an extension cord with this Air Mover.

READ AND SAVE THESE INSTRUCTIONS
WARNING – DO NOT LEAVE THE AIR MOVER UNATTENDED WHEN IT IS PLUGGED IN AND/OR OPERATING. UNPLUG THE UNIT WHEN NOT IN USE.

GROUNDING INSTRUCTIONS

This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING – IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRIC SHOCK. CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO WHETHER THE OUTLET IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG PROVIDED WITH THE APPLIANCE – IF IT WILL NOT FIT THE OUTLET, HAVE A PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN.
GROUNDING INSTRUCTIONS (CONT’D.)
This appliance is for use on a nominal 120-volt circuit and has a grounded plug that looks like the plug illustrated in sketch A. A temporary adaptor that looks like the adaptor illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (sketch A) can be installed by a qualified electrician. The green-colored rigid ear, lug or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw. IN CANADA, THE USE OF A TEMPORARY ADAPTOR IS NOT PERMITTED BY THE CANADIAN ELECTRICAL CODE. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance.

GROUNDING METHODS

shop-vac 1032005 Professional 500 Max CFM Air Mover - GROUNDING
METHODS

UNPACKING

Unpack air mover from the carton.

OPERATION

WARNING – TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS AIR MOVER WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
Follow these instructions to operate your air mover:

  1. To use your unit, place the unit in the area most suitable for your application. Several factors need to be considered; the unit must be placed close enough to an AC outlet to be plugged in, there must be a minimum clearance of two feet from either side of the unit to allow for proper airflow, and the unit should not be placed where it can become a tripping or safety hazard.
  2. Place the unit in the proper operating position for your application. Refer to the Operating Positions section in this manual.
  3. To use multiple air movers, refer to the Multiple Air Mover instructions in this section.
  4. Plug the unit into the wall.
  5. Turn the unit on and select the air speed by turning the switch, located near the top handle, clockwise.
  6. When your drying job is completed, turn the unit off and follow the directions for Storage in this manual.

USING MULTIPLE AIR MOVERS

  1. Your unit comes with receptacles for use with multiple units. To use this feature, position the first air mover following the instructions listed above in this section. This unit may be turned on while connecting multiple units.
  2. Plug the second unit into one of the receptacles on the first unit. Place the second unit in the operation position and the area most suitable for your application. The second unit may be turned on at this time.
  3. A third unit may be plugged into the remaining receptacles on the first unit or plugged into one of the receptacles in the second unit. The third unit may be turned on at his time.
  4. The receptacles on the unit are equipped with a circuit protector that will shut off power to the unit should the receptacles become overloaded. If this happens, move the switch to the off position on the unit and any units connected to it. Press the reset button located above the receptacle; then turn the unit on and any units
    connected to it.

OPERATION (CONT’D.)
NOTE:
It is not recommended to use the receptacles on the unit for appliances other than another air mover of the same ampere rating. To determine the ampere rating of your unit, refer to the nameplate located on the unit.
OPERATING POSITIONS
The air mover may be set in one of three operating positions. Pick the position best suited for your application.

  1. Use the down position for applications such as; drying wet floors, shampooing carpets, etc. To use this position simply place the unit on its base.

  2. Use the angle position for applications such as, drying plaster on walls or drying wet furniture. To use this position, tilt the unit backward so it rests on the support.

  3. Use the up position for applications such as; drying paint on the ceiling. To use this position, lay the unit on the back side with the front grill pointing towards the ceiling.

CLEANING

WARNING – TO REDUCE THE RISK OF INJURY FROM THE AIR MOVER ACCIDENTALLY STARTING, UNPLUG THE POWER CORD BEFORE CLEANING.
The outside of the unit may be cleaned with a damp cloth to remove any dust or residue.

USER SERVICING INSTRUCTIONS

WARNING – BE SURE TO DISCONNECT THE POWER SUPPLY BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY COMPONENTS.
Do not attempt to service your air mover beyond that described in the user manual. For all other servicing, follow instructions under Warranty Section.

LUBRICATION

No lubrication is necessary as the motor is equipped with lifetime lubricated bearings.

STORAGE

  1. Before storing your air mover it should be cleaned. For cleaning instructions, refer to the Cleaning section in this manual.
  2. Wrap the power cord around the carry handle on the top of the unit to keep it untangled.

3. If you have more than one unit to store they may be stored by stacking them. Stack the units by placing them on their sides making sure the indented side is facing down. Do not stack the units more than 3 high. Never operate the unit while it is on its side or stacked. THE AIR MOVER SHOULD BE STORED INDOORS.

shop-vac 1032005 Professional 500 Max CFM Air Mover -
STORAGE

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSES SOLUTION
Will not start 1. Power cord not plugged into an outlet

2. No Power at the outlet
3. Defective switch or motor| 1. Plug cord into an outlet
2. Plug the cord into another outlet
3. Contact Shop-Vac® customer service

WARNING – IF ANY OF THE MOTOR HOUSING PARTS SHOULD BECOME DETACHED OR BROKEN, EXPOSING THE MOTOR OR ANY OTHER ELECTRICAL COMPONENTS, OPERATION SHOULD BE DISCONTINUED IMMEDIATELY TO AVOID PERSONAL INJURY OR FURTHER DAMAGE TO THE AIR MOVER. REPAIRS SHOULD BE MADE BEFORE REUSING THE AIR MOVER.
.ONE-YEAR HOME USE WARRANTY
Your Shop-Air® Air Mover is warranted for normal household use, in accordance with the User Manual, against original defects in material and workmanship during the warranty period. A 90-day limited warranty will apply for commercial or rental use. Shop-Vac warrants placing this product in correct operating condition, by repair or parts replacement, during the warranty period, without charge. Shop-Vac ® assumes no responsibility for damage or faulty performance caused by misuse, careless handling, and where repairs or modifications have been made. Do not attempt to service your air mover beyond that described in the User Manual. Proof of purchase date is required. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province. The warranty is void outside the United States and Canada.
Customers in the United States: for product service contact Shop-Vac Customer Service, at www.shopvac.com/support. Visit www.shopvac.com for your parts list schematic.

S HOP-VAC®
2323 Reach Road
Williamsport, PA 17701
570-326-3557
www.shopvac.com
Patents Issued and Pending.
© 2021 Shop-Vac®.
All Rights Reserved.
Shop-Vac® is a registered trademark of Shop-Vac USA, LLC.

Documents / Resources

| shop-vac 1032005 Professional 500 Max CFM Air Mover [pdf] User Manual
1032005, Professional 500 Max CFM Air Mover, 1032005 Professional 500 Max CFM Air Mover
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

shop vac User Manuals

Related Manuals