metabo GB 18 LTX BL Q I Cordless Drill Driver Tapper Instruction Manual
- June 12, 2024
- metabo
Table of Contents
- GB 18 LTX BL Q I
- GB 18 LTX BL Q I Cordless Drill Driver Tapper
- Declaration of Conformity
- Specified Use
- General Safety Instructions
- Special Safety Instructions
- Figures
- Overview
- Use
- Troubleshooting
- Accessories
- Repairs
- Environmental Protection
- Technical Data
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GB 18 LTX BL Q I
Original Instructions
www.metabo.com
Made in Germany
GB 18 LTX BL Q I Cordless Drill Driver Tapper
Declaration of Conformity
We, being solely responsible, hereby declare that these cordless tappers /
cordless drills/drivers, identified by type and serial number 1), meet all
relevant requirements of directives 2) and standards 3). Technical documents
at 4)
– Fig. K+L.
For UK only:
*** We as manufacturer and authorized person to compile the technical file,
see 4) Fig. L, hereby declare under sole responsibility that these cordless
tappers / cordless drills/drivers, identified by type and serial number *1)
Fig. K, fulfill all relevant provisions of following UK Regulations S.I.
2016/1091, S.I. 2008/1597, S.I. 2012/3032 and Designated Standards EN
62841-1:2015, EN 62841-2-1:2018, EN 62841-2-2:2014, EN IEC 63000:2018.
Specified Use
The cordless tapper / cordless drills/drivers are suitable for drilling in
metal, wood, plastic and similar materials, and also for screwdriving and
cutting internal threads.
The user bears sole responsibility for any damage caused by inappropriate use.
Generally accepted accident prevention regulations and the enclosed safety
information must be observed.
General Safety Instructions
** For your own protection and for the protection of your power tool, pay
attention to all parts of the text that are marked with this symbol!
WARNING – Read the operating instructions to reduce the risk of injury.
WARNING** – Read all safety warnings, instructions, illustrations and
specifications provided with this power tool.
Failure to follow all instructions listed below may result in electric shock,
fire and/or serious injury. Keep all safety instructions and information for
future reference.
Always include these documents when passing on your power tool.
Special Safety Instructions
Use the additional handle supplied with the tool. Loss of control can cause
personal injury. Brace the power tool properly before use. This tool produces
a high output torque and without properly bracing the tool during operation,
loss of control may occur resulting in personal injury.
Hold the power tool by insulated gripping surfaces, when performing an
operation where the cutting accessory may contact hidden wiring. Cutting
accessory contacting a “live” wire may make exposed metal parts of the power
tool “live” and could give the operator an electric shock.
Safety instructions when using long drill bits:
a) Never operate at higher speed than the maximum speed rating of the drill
bit. At higher speeds, the bit is likely to bend if allowed to rotate freely
without contacting the workpiece, resulting in personal injury.
b) Always start drilling at low speed and with the bit tip in contact with the
workpiece. At higher speeds, the bit is likely to bend if allowed to rotate
freely without contacting the workpiece, resulting in personal injury.
c) Apply pressure only in direct line with the bit and do not apply excessive
pressure. Bits can bend causing breakage and loss of control, resulting in
personal injury.
Ensure that the spot where you wish to work is free of power cables, gas lines
or water pipes (e.g. using a metal detector).
Always hold the machine with both hands on the designated handles, take a
secure stance and concentrate on the work.
WARNING – Always wear protective goggles.
Protect battery packs from water and moisture!
Do not expose battery packs to fire!
Do not use faulty or deformed battery packs!
Do not open battery packs!
Do not touch or short circuit battery pack contacts!
A slightly acidic, flammable fluid may leak from defective Li-ion
battery packs!
If battery fluid leaks out and comes into contact with your skin, rinse
immediately with plenty of water. If battery fluid leaks out and comes into
contact with your eyes, wash them with clean water and seek medical attention
immediately!
If the machine is defective, remove the battery pack from the machine.
Remove the battery pack from the machine before making any adjustments,
changing tools, maintaining or cleaning.
Make sure that the tool is switched off before fitting the battery pack.
Keep hands away from the rotating tool!
Remove chips and similar material only when the machine is at a standstill.
Secure the workpiece to prevent slipping or rotation (e.g. by securing with
screw clamps).
LED light (14): do not observe the LED radiation directly with optical
instruments.
CAUTION Do not stare at operating lamp.
Reducing dust exposure:
WARNING – Some dust created by power sanding, sawing, grinding, drilling,
and other construction activities contains chemicals known to cause cancer,
birth defects or other reproductive harm. Some examples of these chemicals
are:
– Lead from lead-based paints,
– Crystalline silica from bricks and cement and other masonry products, and
– Arsenic and chromium from chemically treated lumber.
Your risk from these exposures varies, depending on how often you do this type
of work. To reduce your exposure to these chemicals: work in a wellventilated
area, and work with approved safety equipment, such as those dust masks that
are specially designed to
filter out microscopic particles.
This also applies to dust from other materials such as some timber types (like
oak or beech dust), metals, asbestos. Other known diseases are e.g. allergic
reactions, respiratory diseases. Do not let dust enter the body.
Observe the relevant guidelines and national regulations for your material,
staff, application and place of application (e.g. occupational health and
safety regulations, disposal).
Collect the particles generated at the source, avoid deposits in the
surrounding area.
Use suitable accessories for special work. In this way, fewer particles enter
the environment in an uncontrolled manner.
Use a suitable extraction unit.
Reduce dust exposure with the following measures: – do not direct the escaping
particles and the exhaust air stream towards yourself or nearby persons or
towards dust deposits,
– use an extraction unit and/or air purifiers,
– ensure good ventilation of the workplace and keep
it clean using a vacuum cleaner. Sweeping or blowing stirs up dust.
– Vacuum or wash protective clothing. Do not blow, beat or brush protective
gear.
Transport of li-ion battery packs:
The shipping of li-ion battery pack is subject to laws related to the carriage
of hazardous goods (UN 3480 and UN 3481). Inform yourself of the currently
valid specifications when shipping li-ion battery packs. If necessary, consult
your freight forwarder. Certified packaging is available from Metabo.
Only send the battery pack if the housing is intact and no fluid is leaking.
Remove the battery pack from the machine for sending. Prevent the contacts
from short-circuiting (e.g. by protecting them with adhesive tape).
Figures
Illustrations are provided at the beginning of the operating instructions.
Symbol explanation:
| Movement direction
---|---
| Drill bit
| Slow
| Fast
1| First gear
2| Second gear
| Screws
| Drilling, screwing
| Thread tapping
Nm| Torque
Overview
Fig. A
- Keyless chuck
- Additional handle
- Slide switch (drilling, threadtapping)
- Gear switch
- Rotation selector switch (rotation setting, transport lock) – both sides of the machine
- Handle
- Bit depot *
- Belt hook *
- Battery pack release button
- Capacity indicator button *
- Capacity and signal indicator *
- Battery pack *
- Setting wheel (pulse function, torque control, max. torque)
- LED lamp (Working light and red warning lamp)
- Trigger switch
*equipment-specific
Use
7.1 Electronic safety shutdown (…LTX BL…)
In case of sudden rotation of the power tool around the drill axis, e.g. due
to catching/jamming of the accessory, the machine switches off automatically –
for better control of the machine and high user protection compared to
machines without this function.
The shutdown is indicated by a single red flashing of the LED light (14) and a
single beep.
7.2 Battery pack, capacity and signal indicator vFig. B
Charge the battery pack before use.
Recharge the battery pack if performance diminishes.
Instructions on charging the battery pack can be found in the operating
instructions of the Metabo charger.
7.3 Removing and inserting the battery pack Fig. C
7.4 Setting the direction of rotation, engaging the transporting safety
device (switch-on lock) Fig. D
7.5 Select the gear Fig. E
** Do not set the gear switch (4) unless the motor has stopped completely!
7.6 Set drill, thread tapping Fig. A
Activate slide switch (3).
Note: To screw the sliding switch (3) select the “Drill” position.
7.7 Setting torque control, maximum torque, pulse function
** Do not work for long periods with pulse function switched on! (The motor
can overheat.)
Fig. F
Set the desired operating mode at the setting wheel (13):
= Pulse function
1…10 = Torque control
= maximum torque
Note: Pulse function is only available when sliding switch (3) is set to
“Drill”.
7.8 Switching On/Off, setting the speed Fig. A
Switching on, speed: press the trigger switch (15).
Press in the trigger switch to increase the rotational speed.
Switching off: release the trigger switch (15).
Note: the noise that the machine makes when it switches off is due to the
design (quick stop) and has no influence on the function or the service life
of the machine.
7.9 Keyless chuck Fig. G
With a soft tool shank, retightening may be required after a short drilling
period.
Cleaning: from time to time, hold the machine vertically with the chuck facing
downwards and turn the sleeve fully in the direction “GRIP, ZU” and then turn
fully in the direction “AUF, RELEASE”. The dust collected falls from the
keyless chuck.
7.10 Threadcutting Fig. H
** Only use machine tappers, which fulfil the following conditions:
– Only use undamaged and sharp machine taps.
– Only use machine taps for right-hand threads.
Preparations:
– Make a hole (with a diameter that fits the tap used).
– Set the gear switch (4) to Gear “1”.
– Move the sliding switch (3) to “Thread tapping”
– Adjust setting wheel (13) (see fig. below):
The appropriate setting depends on many factors, in principle the following
applies:
a) Blind holes and small through holes:
For blind holes, do not select too much torque so that the tap does not snap
when it reaches the bottom of the hole. The Pulse position corre-sponds to the
smallest torque and the smallest speed. Both values increase up to position 4.
b) Through holes:
Select a larger torque. From position 4 the speed remains the same and only
the torque increases. For “Maximum torque” select position . – Attach the chuck matching the tap (chuck “M8-12”/”M 4-6”)
– Open the chuck.
– Insert tap.
– Insert taps of sizes M8 – M12, to the stop in the chuck “M8-12” so that the
square is held by the holder inside the chuck.
– Insert taps of sizes M4 – M6, to the stop in the chuck “M4-6” so that the
square is held by the holder inside the chuck.
– Close chuck and clamp tight.
– Lubricate hole and tap with appropriate cutting oil.
Tappingthread
– Place tap on the hole.
– Move machine in axial direction.
– Depress the trigger switch (15) and at a low speed and with moderate
pressure, let the tap cut into the hole. The speed can be increased during the
thread tapping.
– When the desired thread depth is reached, pull the machine evenly from the
hole while keep the trigger switch (15) depressed. The machine automatically
changes its direction of rotation.
Note: If the sliding switch (3) is in the “Thread tapping” position,
right and left pulse functions are not available.
Note:** If the sliding switch (3) is in the position “Thread tapping”
position and there is no pressure on the tap, the machine runs in left mode!
If pressure is placed on the tap, the machine automatically changes to right
mode.
7.11 Chuck with quick-change system Quick
Fig. I
To remove: Push the interlock ring forward (a), advance and pull off the chuck
(b).
To fit: push the interlock ring forward and move the chuck as far as the limit
stop on the drill spindle.
7.12 Fitting the belt hook (equipmentspecific) / bit depot (equipment-
specific) Fig.J
Fit the belt hook (8) as shown.
Fit the bit depot (7) as shown.
Troubleshooting
8.1 Defective electronic safety shutdown
(…LTX BL…)
Red continuous lighting of the LED lamp (14) signals a defective safety
shutdown.Have the machine repaired. See chapter 10.
8.2 The machine’s multifunctional monitoring system
If the machine switches off automatically, the machine electronics have
activated automaticprotection mode. There will be a warning signal (beep). The
beeping stops after a maximum of 30 seconds or when the trigger switch (15) is
released.
In spite of this protective function, overloadingis still possible with
certain applications and can result in damage to the machine.
Causes and remedies:
-
Battery pack almost empty Fig. A, B (Theelectronics protect the battery pack against damage through total discharge).
If one LED (11) is flashing, the battery pack is almost flat. If necessary, press the button (10) and check the LEDs (11) to see the charge level.If the battery pack is almost flat, it must be recharged. -
Long continuous overloading of the machine willactivate the temperature cut-out.
Leave the machine or battery pack to cool.
Note: if the battery pack feels very warm, the
pack will cool more quickly in an “AIR COOLED”charger.
Note: the machine will cool more quickly if you operate it at idling speed. -
Metabo safety shutdown: the machine has SHUT DOWN by itself. If the speed suddenly drops (for example, if the machine suddenly seizes or kickback occurs), the machine switches off. Switch off the machine at the trigger switch (15). Switch it on again and continue to work as normal. Try to prevent the machine from seizing.
8.3 Note:
The LED lamp (14) switches off automatically after a specific time.
Accessories
Use only original Metabo or CAS (Cordless Alliance System) battery packs and
accessories.
Use only accessories that fulfil the requirements and specifications listed in
these operating instructions.
Fit accessories securely. If the machine is operated in a holder: secure the
machine well. Loss of control can cause personal injury.
For a complete range of accessories, see www.metabo.com or the catalogue.
Repairs
**** Repairs to electrical tools must ONLY be carried out by qualified
electricians!
Contact your local Metabo representative if you have Metabo power tools
requiring repairs. See www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.
Environmental Protection
Observe national regulations on environmentally compatible disposal and on the
recycling of disused machines, packaging and accessories.
Packaging materials must be disposed of according to their labelling in
accordance with municipal guidelines. Further information can be found at
www.metabo.com in the “Service” section.
Battery packs may not be disposed of with regular waste. Return faulty or used
battery packs to your Metabo dealer!
Do not allow battery packs to come into contact with water!
Protect the environment, and do not dispose of power tools and battery packs
with household waste.
Observe national regulations on separated collection and recycling of disused
machines, packaging and accessories.
Discharge the battery pack in the power tool before disposal. Prevent the
contacts from short-circuiting (e.g. by protecting them with adhesive tape).
Technical Data
Fig. K. We reserve the right to make technical improvements.
U = Voltage of battery pack
n0 = No-load speed
Tightening torque for screwing:
M1 = Soft screwing application (wood)
M2=Pulse torque
M3 = Hard screwing applications (metal)
M4 = Adjustable torque
D1 max = Max. thread diameter
D2 max = Max. drill bit diameter in steel
D3 max = Max. drill bit diameter in soft wood
m = Weight (with the smallest battery pack)
G = Spindle thread
D max = Chuck clamping range
Measured values determined in conformity with EN 62841.
Permitted ambient temperature during operation: -20 °C to 50 °C (limited
performance with temperatures below 0 °C). Permitted ambient temperature for
storage: 0 °C to 30 °C
Direct current
The technical specifications quoted are subject to tolerances (in compliance
with the relevant valid standards).
Emission values
These values make it possible to assess the emissions from the power tool and
to compare different power tools. The actual load may be higher or lower
depending on the operating conditions, the condition of the power tool or the
accessories.
Please allow for breaks and periods when the load is lower for assessment
purposes. Arrange protective measures for the user, such as organisational
measures based on the adjusted estimates.
Vibration total value (vector sum of three directions) determined in
accordance with EN 62841:
ah, ID = Vibration emission value (impact drilling in concrete)
ah, D = Vibration emission value (Drilling in metal)
ah, S = Vibration emission value (screwing without impact)
Kh, … = Uncertainty (vibration)
Typical A-effective perceived sound levels:
LpA = Sound-pressure level
LWA = Acoustic power level
KpA, KWA=Uncertainty (noise level)
The noise level can exceed 80 dB(A) during operation.
**** Wear ear protectors!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>