COSLUS F5029A Water Dental Flosser Teeth Pick User Manual
- June 12, 2024
- COSLUS
Table of Contents
Oral Irrigator
User Manual
Model:F5029A
Thanks for your purchasing, please read this manual carefully before using, and save it for future use.
**** IMPORTANT SAFETY CAUTIONS
All information in this part is provided to instruct you to use the appliance in a correct and safe way so that you can avoid injures to yourself and others. as well as damage to property.
Dangers
- Toddlers, infants, people who are unable to operate are prohibited from using the appliance. Please keep it away from children.
- Never alter the appliance. Never try to disassemble or repair it by yourself.
- Do not place or store the appliance where it may fall or be pulled into tub or sink.
- Do not touch the appliance if it has fallen into water. Unplug the appliance immediately.
- Do not use the appliance while bathing.
**Warnings**
- The appliance can be used by children aged 8 years and above. Person with reduced physical, sensory or mental capabilities or lack of experience and knowledge are not allowed to use unless they have guardian supervision or instruction concerning safe using.
- Children shall not play with the appliance. Cleaning and maintenance shall not be made by children without supervision.
- The appliance is only to be used with power supply unit provided with the appliance.
- The battery must be removed from the appliance before it is scrapped.
- Unplug the appliance from power supply before removing the battery.
- The battery should be disposed of safely. Regarding how to remove the battery, please refer to disposal instructions.
- If external cable or cord is damaged, please ask manufacturer, service agent or qualified professional person for help to avoid hazard.
- Keep the cable or cord away from heated surfaces.
- Please do not use the appliance if you lost the nozzle.
- Do not fill water tank with liquid warmer than 40 C .
Note:
There may be some liquid remaining inside the main appliance before use (tank,
water suction tube, etc), this is the remaining distilled water for
performance (water flow) test, so there are no health concerns.
WHAT’S IN THE BOX
-
Main unit x 1
-
Micro bubble nozzle x 2
-
U-type nozzle x 1
-
Periodontal nozzle x 1
-
Tongue scraper x 1
-
Dental mirror x 4
-
Type-C cable x 1
(adapter is not included) -
User manual x 1
PRODUCT OVERVIEW
**USE INSTRUCTION
**
How to charge
- Take down the cover to open charging port, securely plug cable into the charging port on the main unit Make sure no liquid remaining inside the port before plugging.(Fig. 1)
- Connect charging adaptor USB securely into power outlet. (Fig. 2)
- “CH” indicator blinks during the appliance is charging, and it will be steady on after it is fully charged. (Fig. 3)
- Cover the charging port again after charging is finished. (Fig. 4)
Note: If “CH” indicator is blinking during or after an irrigating, that
means the battery need to be recharged. One full charging will take about 2.5
hours.
How to Operate
Do not switch on the appliance before placing the nozzie in your mouth.
-
Attach nozzle onto the main unit. (Fig.5)
-
Open the water tank .(Fig .6)
-
. Fill the tank with water(not warmer 40 C), then close the cap. (Fig.7)
-
Press mode button to select desired mode. During irrigating, you can change the working mode.
(Fig.8)
Normal: For normal cleaning.
Soft: For gently cleaning sensitive gums.
Puts: For cleaning and massaging gums.
Custom: Long press mode button for 3s, indicator light will flash, and water pressure will increase one level (level 1~6) after each pressing. If you release the mode button, water pressure will be selected. -
Upright hold the main unit with nozzle tip point toward your teeth. (Fig.9)
-
Keep your mouth open slightly so that water can flow out. (Fig.10)
-
Press On/Off button to start irrigating. (Fig. 11)1). Direct water flow at 90° to teeth and gums
2). Direct water flow slowly along teeth
3). Direct water flow along gum line with nozzle tip at 90°4).
4)Clean between teeth and around any braces, crowns or bridgework thoroughly
5}Press On/Off button to turn it off, then press nozzie release button to replace other nozzie you need.
9. After irrigating, press On/Off button to turn the appliance off.
After Using (Fig.12)
- Open water tank cap and dispose of water inside the tank.
- Press On/Off button to turn on and drain water inside the appliance.
- Press On/Off button again to turn it off, and close water tank cap.
- Wipe the appliance with dry cloth.
- It is recommended to clean the inside of water tank once a week
Note:
To prevent bacteria breeding, make sure there is no remaining water inside. If
you’re not going to use the appliance for a long time, be sure to wipe and dry
it as soon as possible before storing.
NOZZLE INSTRUCTION
Micro bubble nozzie: daily clean teeth, gum line, fissure, remove food residue, stain, plaque, etc.
U-type nozzle: Clean teeth internally. Clean dirt and residues that cannot be removed from outside to inside.![COSLUS F5029A Water Dental Flosser Teeth Pick
- Nozzle 3](https://manuals.plus/wp-content/uploads/2023/07/COSLUS-F5029A-
Water-Dental-Flosser-Teeth-Pick-Nozzle-3.png) Periodontal nozzle: clean
gingival sulcus, especially suitable for those who are suffering from
periodontal diseases. When cleaning periodontal pocket, please use the lowest
water pressure. Direct water flow along the gum line with nozzle tip at 45°
and turn it on. Tongue Scraper: clean tongue surface,
remove bad breath, food residue and thick tongue fur. When cleaning tongue,
please use the soft mode. Lean forward, put scraper on your tongue and tum it
on, then move gently from back to front. You can adjust water pressure
according to your need.
Note:
It is recommended to replace cleaning nozzle every 6 months for better cleaning experience.
MAINTENANCE
Use only water or neutral cleaning agent to clean the appliance. Never use caustic or abrasive agents (e.g., vinegar or lime scale removers), since they may damage the appliance. Do not use water warmer than 40C. Keep the appliance away from high temperature and avoid direct sunlight.
Main unit
- Wipe the dirt by cloth with soapy water.
- Do not submerge the main unit in water to clean.
- Dry after washing with water.
Water tank cap
- Wipe off any grime and dirt with a cloth.
Nozzle
- Wash with water and wipe with soft cloth.
- Replace the nozzle every 6 months.
Water suction tube
- Wash with water and wipe with soft cloth.
- Do not bend, pull or twist the water suction tube.
Tank
- Wash with water and wipe with soft cloth.
- Dry the tank when not using for a long period.
TROUBLESHOOTING
Problem | Cause | Solution |
---|---|---|
It does not work | You’ve just purchased the appliance or it has been left | |
unused for more than 3 months. | Charge the appliance for at least 3 hours. | |
It only works for a few minutes even after charging | The battery has reached | |
the end of its service life. | Contact service center for support. | |
Charging time was insufficient. | Charge the appliance for at least 3 hours. | |
Water pressure is very low | There is dirt stuck in the nozzle. | Replace the |
nozzle.
The nozzle is deformed.
There is dirt stuck in the filter.| Clean the filter.
Water does not come out| The tank is empty.| Fill up tank.
The appliance is tilted too much while using.| Use the appliance in a vertical
direction.
You’ve just purchased the appliance or it has been left unused for a period.|
Pull out the nozzle, then flush nozzle hole on the main unit.
DISPOSAL
Rechargeable battery inside the appliance is easy to remove for recycling.
At the end of its service life and prior to disposal, please remove the
battery following instructions below.
Note: During below operation, be sure to protect your eyes, hands,
fingers, and the surface on which you work.
- Remove screw caps and screws on the bottom with screwdriver.(Fig. 13)
- Open the bottom cover.(Fig.14)
- Open the shell and take out core components.(Fig.15)
- Cut off battery wire and pull out batteries from the inner. (Fig. 16
Warm up : if you have any question about recycling, please contact your local waste management office.
www.coslus.com
Tel: +1(855) 594-3950
E-mail: support@coslus.com
fade in China Made in China
Documents / Resources
|
COSLUS F5029A Water Dental Flosser Teeth
Pick
[pdf] User Manual
B0C33D7Y24, B0BZ7Y37N3, B0BS1CFTTS, F5029A, F5029A Water Dental Flosser Teeth
Pick, Water Dental Flosser Teeth Pick, Dental Flosser Teeth Pick, Flosser
Teeth Pick, Teeth Pick, Pick
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>