Yale D002 Floodlight Camera User Guide
- June 12, 2024
- Yale
Table of Contents
Yale D002 Floodlight Camera
Product Information
The product is a floodlight camera designed for security purposes. It comes with a manual that provides information and safety instructions for installing and operating the camera. The product requires an electrical connection and should be installed by a licensed electrician to ensure safety.
Disclaimer
Working with electricity can be dangerous unless proper safety precautions are
taken. If you are not comfortable or inexperienced with the processes and
tools described in this manual, we recommend that you hire a licensed
electrician.
Product Usage Instruction
Installation
The camera should be installed on a strong wall surface with a distance of
110mm between the two holes. The installation involves drilling holes,
attaching the mounting box to the wall, connecting the wires, and fixing the
camera with mounting screws. It is important to follow code standards when
installing wired connections and to ground the fixture properly. Do not
install the camera near combustible or flammable surfaces.
Step-by-Step Installation Instructions
- Insert the drilling template where you want the floodlight camera to be installed. Using the drilling template drill the two holes indicated on the template.
- Turn the adjusting knobs to loosen the lights, and adjust the light angles to give space to the mounting screw. Loosen the mounting screw to open the mounting box, and then loosen the screw on the ground terminal to remove the ground wires.
- Attach the mounting box to the wall with the self-tapping screws as the UP arrow shows. Before using the self-tapping screws, attach the wall plugs to the self-tapping screws.
- Hook one end of the hook into the hole on the mounting box, and the other end to the edge of the camera, so you can free both hands for the installation.
- Take out the terminal board from the mounting box. Connect the blue wires (neutral wires) to terminal N, the brown wires (live wires) to terminal L, and then the yellow and green strip wire to the ground terminal on the board.
- Put away all the wires, attach the camera to the mounting box, and fix the camera with mounting screws.
- Adjust the light and lens angle, and keep the PIR detector parallel to the ground to ensure optimal detection.
Operating with Yale View App
The camera can be operated using the Yale View app, which can be downloaded
from Google Play or App Store. The app allows you to view live streams and
recorded video footage from your camera.
Step-by-Step Operating Instructions
- Power on the camera.
- Scan the QR code or search the Yale View app in Google Play or App Store to download and install the Yale View app. If you have installed the app, update it to the latest version.
Disclaimer
This guide is for informational purposes only. Working with electricity can be dangerous unless proper safety precautions are taken. If you are not comfortable or are inexperienced with the processes and tools described in this manual, we recommend that you hire a licensed electrician.
About the Guide
- All the design and software here are subject to change without prior written notice.
- All trademarks and registered trademarks mentioned are the properties of their respective owners.
- Please visit our website or contact your local service engineer for more information.
- If there is any uncertainty or controversy, please refer to our final explanation.
Identifying the parts
Note
In the screw package, there are 3 expansion bolts, 3 silicone gaskets, and 3
self-tapping screws.
Assembly
Application
When mounted at 3 m (10 feet) off the ground, with the PIR lens parallel to the ground, the motion detector is optimized to detect human-sized objects at up to 10 m (33 feet).
Camera Introduction
Note: Press and hold the reset button for 10 s to reset the camera.
The pattern of the LED indicator is included in the following table.
LED Indicator Status | Device Status |
---|
Off
| Powered off/LED turned off
Rebooting after reset
Red light on
| Booting
Device malfunction
Green light flashing| Waiting for network
Green light on| Operating properly
Red light flashing| Network connection failed
Green and red light
flashing alternately
| Firmware updating
Installing Camera
WARNING
Risk of electrical shock.
- Be sure to disconnect the power at the fuse or circuit breaker before installation.
- Verify that the supply voltage is correct. Connect the fixture to a 100–240VAC 50/60 Hz power source.
- Properly ground fixture.
- Always follow code standards when installing a wired connection.
- We strongly suggest that you hire a licensed electrician to install the camera.
- For permanently connected equipment, a readily accessible disconnect device shall be incorporated external to the equipment.
- For pluggable equipment type B or permanently connected equipment, the maximum rating of an overcurrent protective device to be provided external to the equipment is 20A.
Risk of fire.
Do not install the camera near combustible or flammable surfaces.
Note
- Do not connect this light fixture to a dimmer switch or timer.
- Make sure that the mounting surface is strong enough to hold at least three times of the device’s weight.
Step 1
- Insert the drilling template where you want the floodlight camera to be installed. Using the drilling template drill the two holes indicated on the template.
- If there are no holes in the wall, drill two parallel holes on the wall (the distance is 110 mm between the two holes), and then put in the wall plugs.
Step 2
Turn the adjusting knobs to loosen the lights, and adjust the light angles to
give space to the mounting screw. Loosen the mounting screw to open the
mounting box, and then loosen the screw on the ground terminal to remove the
ground wires.
Step 3
Attach the mounting box to the wall with the self-tapping screws as the UP
arrow shows.
Note:
Before using the self-tapping screws, attach the wall plugs to the self-
tapping screws.
Step 4
Hook one end of the hook into the hole on the mounting box, and the other
end to the edge of the camera, so you can free your both hands for the
installation.
Step 5
Take out the terminal board from the mounting box. Connect the blue wires
(neutral wires) to terminal N, the brown wires (live wires) to terminal L, and
then the yellow and green strip wire to the ground terminal on the board.
Step 6
Connect the two removed yellow and green striped wires (ground wires) to the
ground terminal again, tighten the screw on the ground terminal, and then put
back the terminal board with the insulating gasket in the mounting box.
Step 7
Put away all the wires, attach the camera to the mounting box, and fix the
camera with mounting screws.
Step 8
Adjust the light and lens angle, and keep the PIR detector parallel to the
ground to ensure optimal detection.
Operating with the Yale View app
-
Step 1
Power on the camera. -
Step 2
Scan the following QR code or search the Yale View app in Google Play or App Store to download and install the Yale View app.
Note If you have installed the app, update it to the latest version. -
Step 3
Run the Yale View app, and then register an account for first use. -
Step 4
Wait for booting to be finished, and then the camera indicator flashes with green light. -
Step 5
Connect your smartphone to your Wi-Fi network, make sure that your smartphone is connected to a Wi-Fi network with a 2.4 GHz band, and then do the following operations to finish adding the camera.
Note
- If you have more than one camera, do step 5 to add them one by one.
- If the Wi-Fi network changes or the indicator status goes wrong, reset the camera, and then do step 5 to add it again.