FUJITSU FOC1524VJAZCA1 iM Air Conditioners User Manual
- June 13, 2024
- FUJITSU
Table of Contents
- FUJITSU FOC1524VJAZCA1 iM Air Conditioners
- Product Information
- Product Usage Instructions
- Features and Benefits
- Air Conditioners
- General Data/Electrical Data
- Accessories
- Unit Dimensions
- CLEARANCES
- Control Wiring
- Application Guidelines
- Refrigerant Line Size Information
- Performance Data
- THE ECONET SMART THERMOSTAT
- GENERAL TERMS OF LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FUJITSU FOC1524VJAZCA1 iM Air Conditioners
Product Information
- The iM Air Conditioners FOC15 is a series of air conditioners manufactured by Fujitsu General America, Inc. It offers cooling efficiencies up to 15.2 SEER2/9.8 EER2 and comes in nominal sizes ranging from 2 to 5 tons (7.0 to 17.6 kW).
- The cooling capacities of the FOC15 range from 22.8 to 56.0 kBTU (6.68 to 16.4 kW).
- The FOC15 air conditioners provide precise temperature control, advanced humidity control, and greater efficiency. They feature a 3-speed operation when installed with a 24V two-stage thermostat.
Product Usage Instructions
To use the iM Air Conditioners FOC15, follow these instructions:
- Ensure that the air conditioner is properly installed according to the manufacturer’s guidelines.
- Connect the air conditioner to a suitable power source with the specified line voltage (208/230V-1-60Hz).
- Set the desired temperature and mode using the controls provided on the air conditioner or the connected thermostat.
- If available, use a 24V two-stage thermostat for optimal performance and access to the 3-speed operation feature.
- Monitor the air conditioner’s performance and adjust the settings as needed to maintain the desired temperature and humidity levels.
- If additional accessories are desired, refer to the accessories section of the user manual for compatibility and installation instructions.
- Regularly clean and maintain the air conditioner as recommended in the user manual to ensure efficient operation and prolong its lifespan.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks is under license. Other trademarks and trade names are those of their respective owners.
For detailed information on specific models and their electrical data, refer to the General Data/Electrical Data section of the user manual.
FOC15
- Cooling Efficiencies up to: 15.2 SEER2/9.8 EER2
- Nominal Sizes: 2 to 5 Ton [7.0 to 17.6 kW]
- Cooling Capacities: 22.8 to 56.0 kBTU [6.68 to 16.4 kW]
Features and Benefits
- EcoNet® Enabled: Automatic system configuration and optimization
- Diagnostics & Bluetooth®1 Connectivity: With the BluArch™ Contractor & EcoNet® Apps, built-in technology makes advanced set-up, monitoring, troubleshooting, and repairing the product easier than ever before
- Variable Speed Twin Rotary Compressor & Inverter Drive:
- Features Inverter operation from 40 to 70% capacity or 100% capacity via line voltage with the EcoNet® Smart Thermostat
- 3-speed operation when installed with a 24V two-stage thermostat
- Provides precise temperature control, advanced humidity control, and greater efficiency
- Swept Wing Fan Technology: Features quieter operation and improved unit acoustics
- 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller and lighter footprint while enhancing reliability
- Expanded Valve Space: 3 in. – 4 in. – 5 in. service valve space—provides a minimum working area of 27 square inches for easier access
- Triple Service Access: 15 in. wide, industry-leading corner service access – makes repairs easier and faster
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks is under license. Other trademarks and trade names are those of their respective owners.
Air Conditioners
F
Brand
| O
Product Category
| C
Type
| 15
SEER2
| 24 ****
Capacity BTU/HR
| 3
Type
| J
Voltage
| A
Region
| Z
Refrigerant
| C
Controls
| A
**Major Series**
| 1
**Minor Series**
---|---|---|---|---|---|---|---|---|---|---|---
F – Fujitsu| O – Outdoor Unit| C – AC| 15.2 SEER2| 24 – 24,000 [7.03 kW]
36 – 36,000 [10.55 kW]
48 – 48,000 [14.07 kW]
60 – 60,000 [17.58 kW]
| V – 3+ Stage| J – 1ph, 208-230/60| A – All| Z – R-410A| C – Communicating| A – 1st Design| 1 – 1st Series 2 – 2nd Series
Designates Metric Conversions
Available Models | Description |
---|---|
FOC1524VJAZCA1 | 2 ton 15.2 SEER2 3+ Stage iM Air Conditioner-208/230/1/60 |
FOC1536VJAZCA1 | 3 ton 15.2 SEER2 3+ Stage iM Air Conditioner-208/230/1/60 |
FOC1548VJAZCA1 | 4 ton 15.2 SEER2 3+ Stage iM Air Conditioner-208/230/1/60 |
FOC1560VJAZCA1 | 5 ton 15.2 SEER2 3+ Stage iM Air Conditioner-208/230/1/60 |
Standard Equipment
R-410A Refrigerant
Variable Speed Twin Rotary Compressor
Field Installed Filter Drier
Front Seating Service Valves
Internal Pressure Relief Valve
Internal Thermal Overload
Long Line capability
Low Ambient capability with Kit
3-4-5 Expanded Valve Space
Composite Basepan
2 Screw Control Box Access
15″ Access to Internal Components
Quick release louver panel design
No fasteners to remove along bottom
Optimized Venturi Airflow
Single row condenser coil
Powder coated paint
Rust resistant screws
QR code
External gauge ports
Service trays
General Data/Electrical Data
General Data
Model No.| FOC1524VJAZCA1| FOC1536VJAZCA1|
FOC1548VJAZCA1| FOC1560VJAZCA1
Nominal Tonnage| 2.0| 3.0| 4.0| 5.0
Valve Connections|
Liquid Line O.D. – in.| 3/8| 3/8| 3/8| 3/8
Suction Line O.D. – in.| 3/4| 3/4| 7/8| 7/8
Refrigerant (R410A) furnished oz.¹| 91| 119| 130| 154
Compressor Type| Twin Rotary
Outdoor Coil|
Net face area – Outer Coil| 11.79| 14.4| 16.42| 17.88
Net face area – Inner Coil| —| —| —| —
Tube diameter – in.| 0.276| 0.276| 0.276| 0.276
Number of rows| 1| 1| 1| 1
Fins per inch| 24| 24| 24| 24
Outdoor Fan|
Diameter – in.| 20| 24| 24| 26
Number of blades| 3| 3| 3| 3
Motor hp| 1/5| 1/5| 1/3| 1/2
CFM| 2908| 4138| 4529| 5274
RPM| 1075| 1000| 1075| 1075
watts| 170| 267| 294| 370
Shipping weight – lbs.| 174| 198| 230| 251
Operating weight – lbs.| 167| 191| 223| 244
Electrical Data
Line Voltage Data (Volts-Phase-Hz)| 208/230-1-60|
208/230-1-60| 208/230-1-60| 208/230-1-60
Maximum overcurrent protection (amps)²| 20| 30| 40| 50
Minimum circuit ampacity³| 12| 20| 25| 32
Compressor|
Rated load amps| 10| 15| 20| 25
Locked rotor amps| 65| 70| 96| 119
- Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required.
- HACR type circuit breaker of the fuse.
- Refer to the National Electrical Code manual to determine wire, fuse, and disconnect size requirements.
Accessories
Model No.| FOC1524VJAZCA1| FOC1536VJAZCA1|
FOC1548VJAZCA1| FOC1560VJAZCA1
---|---|---|---|---
Compressor crankcase heater*| N/A| N/A| N/A| N/A
Low ambient control| 47-102709-10| 47-102709-10| 47-102709-10| 47-102709-10
Compressor sound cover| 68-23427-27| 68-23427-28| 68-23427-29| 68-23427-29
Low pressure control| 47-103454-01| 47-103454-01| 47-103454-01| 47-103454-01
High pressure control| 47-103669-02| 47-103669-02| 47-103669-02| 47-103669-02
Liquid Line Solenoid (24 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG24V| 61-AMG24V| 61-AMG24V| 61-AMG24V
Liquid Line Solenoid (120/240 VAC, 50/60 Hz)| Solenoid Valve| 200RD2T3TVLC|
200RD2T3TVLC| 200RD2T3TVLC| 200RD2T3TVLC
Solenoid Coil| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V| 61-AMG120/240V
Crankcase Heater recommended with Low Ambient Kit.
Weighted Sound Power Level (dBA)
Unit Size – Voltage, Series| Standard Rating (dBA) Low Speed/ High
Speed| TYPICAL OCTAVE BAND SPECTRUM (dBA without
tone adjustment)| Sound Power Level [dB(A)] with Sound
Blanket
---|---|---|---
125| 250| 500| 1000| 2000| 4000| 8000
FOC1524VJAZCA1| 63.3| 35.9| 47.9| 55.3| 53.2| 50.4| 47.1| 43.8| ****
Sound Blankets – Standard
71.7| 46.1| 59.1| 63.2| 60.8| 58.7| 56.5| 47.9
FOC1536VJAZCA1| 61.4| 38.5| 48.0| 53.8| 49.2| 45.9| 47.0| 47.4
72.9| 47.5| 59.5| 64.9| 60.7| 62.6| 57.0| 49.6
FOC1548VJAZCA1| 63.8| 42.3| 45.9| 53.5| 48.9| 45.8| 59.1| 36.4
76.2| 49.4| 61.4| 68.1| 53.9| 60.8| 57.4| 48.5
FOC1560VJAZCA1| 65.7| 39.7| 49.0| 58.2| 54.5| 52.2| 53.8| 41.3
76.7| 49.3| 64.6| 68.1| 65.1| 62.6| 58.6| 53.0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
Unit Dimensions
Model No.
| Operating| Shipping
---|---|---
H (Height)| L (Length)| W (Width)| H
(Height)| L (Length)| W (Width)
Inches| mm| Inches| mm| Inches| mm| Inches|
mm| Inches| mm| Inches| mm
FOC1524VJAZCA1| 27.00| 686| 29.75| 756| 29.75| 756| 28.50| 724| 32.38| 822|
32.38| 822
FOC1536VJAZCA1| 27.00| 686| 33.75| 857| 33.75| 857| 28.50| 724| 36.38| 924|
36.38| 924
FOC1548VJAZCA1| 31.00| 787| 33.75| 857| 33.75| 857| 32.50| 826| 36.38| 924|
36.38| 924
FOC1560VJAZCA1| 31.00| 787| 35.75| 908| 35.75| 908| 32.50| 826| 38.38| 975|
38.38| 975
Designates Metric Conversions
CLEARANCES
NOTE: NUMBERS IN () = mm
IMPORTANT:
When installing multiple units in an alcove, roof well, or partially enclosed
area, ensure there is adequate ventilation to prevent re-circulation of the
discharge air.
Control Wiring
Application Guidelines
- Intended for outdoor installation with free air inlet and outlet. The outdoor fan external static pressure available is less than 0.01 -in. WC.
- The minimum outdoor operation air temperature for a cooling mode without a low-ambient operation accessory is 55°F (12.8°C).
- Maximum outdoor operating air temperature is 125°F (51.7°C).
- For reliable operation, the unit should be level in all horizontal planes.
- Use only copper wire for electric connections at the unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
- Do not apply capillary tube indoor coils to these units.
- Factory-supplied filter drier must be installed.
Refrigerant Line Size Information
15/16 SEER2 Variable Speed Air Conditioners
Unit Size| Allowable Liquid Line Size| Allowable Vapor
Line Size| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent
Length (Feet)
< 25| 26- 50| 51- 75| 76- 100| 101-
125| 126- 150
Maximum Vertical Separation/Capacity Multiplier
2.0 Ton*
SEE NOTE 3
| 1/4″| 5/8″| 25 / 1.00| 50 / 0.99| 32 / 0.98| 40 / 0.97| NR| NR
5/16″| 5/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.95
3/8″| 5/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.95
1/4″| 3/4″| 25 / 1.00| 50 / 1.00| 32 / 0.99| 40 / 0.99| NR| NR
5/16″| 3/4″| 25 / 1.00| 50 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.99| 50 /
0.98
3/8″| 3/4″**| 25 / 1.00| 50 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.99| 50 / 0.98
3 Ton
| 5/16″| 5/8″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 37 / 0.91| NR
3/8″| 5/8″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 50 / 0.91| NR
5/16″| 3/4″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 37 / 0.97| 22 / 0.96
3/8″| 3/4″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96
1/2″| 3/4″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96
4 Ton
| 3/8″| 3/4″| 25 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.94| 50 / 0.93
1/2″| 3/4″| 25 / 0.99| 50 / 0.98| 50 / 0.97| 50 / 0.96| 50 / 0.94| 50 / 0.93
3/8″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97
1/2″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97
5 Ton
| 3/8″| 3/4″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 50 / 0.91| NR
1/2″| 3/4″| 25 / 0.99| 50 / 0.97| 50 / 0.95| 50 / 0.93| 50 / 0.91| NR
3/8″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97| 38 / 0.96
1/2″| 7/8″| 25 / 1.00| 50 / 0.99| 50 / 0.98| 50 / 0.98| 50 / 0.97| 50 / 0.96
Designates Metric Conversions
NOTES:
- Do not exceed 150 ft. linear line length.
- *Do not exceed 50 ft. vertical separation if the outdoor unit is above the indoor unit.
- **A 3/4″ suction line should only be used for 2-ton systems if the outdoor unit is below or at the same level as the indoor unit to ensure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
15/16 SEER2 Variable Speed Air Conditioners
Unit Size
| ****
Allowable Liquid Line Size mm [in.]
| ****
Allowable Vapor Line Size mm [in.]
| Outdoor Unit ABOVE or BELOW Indoor Unit Equivalent Length (Meters)
< 25| 26- 50| 51- 75| 76- 100| 101-
125| 126- 150
Maximum Vertical Separation/Capacity Multiplier
2.0 Ton*
SEE NOTE 3
| 6.35 [1/4]| 15.88 [5/8]| 8 / 1.00| 15 / 0.99| 10 / 0.98| 10 / 0.97|
NR| NR
7.94 [5/16]| 15.88 [5/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.97| 15 /
0.96| 15 / 0.95
9.53 [3/8]| 15.88 [5/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96|
15 / 0.95
6.35 [1/4]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 10 / 0.99| 12 / 0.99| NR|
NR
7.94 [5/16]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.99| 15 /
0.99| 15 / 0.98
9.53 [3/8]| 19.05 [3/4]**| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.99| 15 /
0.99| 15 / 0.98
3 Ton
| 7.94 [5/16]| 15.88 [5/8]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 11 /
0.91| NR
9.53 [3/8]| 15.88 [5/8]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 15 / 0.91|
NR
7.94 [5/16]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 11 /
0.97| 7 / 0.96
9.53 [3/8]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 / 0.97|
15 / 0.96
12.70 [1/2]| 19.05 [3/4]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 /
0.97| 15 / 0.96
4 Ton
| 9.53 [3/8]| 19.05 [3/4]| 8 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96| 15 /
0.94| 15 / 0.93
12.70 [1/2]| 19.05 [3/4]| 8 / 0.99| 15 / 0.98| 15 / 0.97| 15 / 0.96| 15 /
0.94| 15 / 0.93
9.53 [3/8]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 / 0.98|
15 / 0.97
12.70 [1/2]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.99| 15 / 0.98| 15 /
0.98| 15 / 0.97
5 Ton
| 9.53 [3/8]| 19.05 [3/4]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 15 /
0.91| NR
12.70 [1/2]| 19.05 [3/4]| 8 / 0.99| 15 / 0.97| 15 / 0.95| 15 / 0.93| 15 /
0.91| NR
9.53 [3/8]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.98| 15 / 0.97|
12 / 0.96
12.70 [1/2]| 22.23 [7/8]| 8 / 1.00| 15 / 0.99| 15 / 0.98| 15 / 0.98| 15 /
0.97| 15 / 0.97
NOTES:
- Do not exceed 46 meters linear line length.
- *Do not exceed 15 meters vertical separation between indoor and outdoor units.
- **19.05mm [3/4″] vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor unit to assure proper oil return.
- Always use the smallest liquid line allowable to minimize refrigerant charge.
- Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not recommended, but are allowed.
- Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
Additional Oil, Oz.
Lineset Length| 50| 60| 70| 80| 90|
100| 110| 120| 130| 140| 150
2T| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6| 7
3T| N/A| N/A| N/A| N/A| N/A| N/A| 1| 2| 3| 5| 6
4T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
5T| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A| N/A
Performance Data
Performance Data @ AHRI Standard Conditions – Cooling
Designated Tested Combination (DTC)
Outdoor Unit| Air Handler| Total Capacity BTU/H
[kW]| Net Sensible BTU/H [kW]| Net Latent BTU/H [kW]|
SEER2| EER2| Indoor CFM [L/s]
FOC1524VJAZCA1| FHRNVV2417| 22,800 [6.7]| 17,600 [5.2]| 5,200 [1.5]| 15.2|
9.8| 750 [354.0]
FOC1536VJAZCA1| FHRNVV3617| 34,200 [10.0]| 26,600 [7.8]| 7,600 [2.2]| 15.2|
9.8| 1,125 [530.9]
FOC1548VJAZCA1| FHRNVV4821| 45,500 [13.3]| 35,500 [10.4]| 10,000 [2.9]| 15.2|
9.8| 1,425 [672.5]
FOC1560VJAZCA1| FHRNVV6024| 55,500 [16.3]| 43,000 [12.6]| 12,500 [3.7]| 15.2|
9.8| 1,675 [790.5]
NOTE:
This data includes DTC (Designated Test Combination) ratings and is for
reference purposes only. A full listing of official ratings and system match-
ups, along with downloadable certificates, can be accessed from the AHRI
website: www.ahridirectory.org.
Designates Metric Conversions.
THE ECONET SMART THERMOSTAT
BUILT-IN WIFI
4.3″ LCD TOUCH SCREEN
- LOCAL WEATHER – Current conditions plus 6-day forecast
- 5 OPERATING MODES – Heat, Cool, Auto, Emergency Heat and Fan Only
- 7-DAY PROGRAMMABLE SCHEDULE – Offers comfort without thought
- ONE-TOUCH AWAY – Quickly switch to your energy-saving away preferences
- VACATION SCHEDULING – Allows you to save while you’re away and come home to comfort
- STANDBY SCREEN – Displays indoor temperature and current weather
OPERATIONAL FEATURES
- AUTOMATIC CHANGEOVER – Transitions between heating and cooling automatically to keep the house comfortable
- INTEGRATED WATER CONTROL – Enables easy water heater management
- SMOOTH ARRIVAL – Prompts the system to start ahead of schedule to ensure the home is at the desired temperature at the scheduled time
- HUMIDITY CONTROL – Supports humidifier accessories or over-cool-based dehumidification
- DETAILED OPERATING STATUS – View pertinent equipment status information and run times
- CONTINUOUS FAN – Offers 5 speeds (Low, Medium Low, Medium, Medium High, High)
- SHORT-CYCLE PROTECTION – Avoids damage to equipment from short-run cycles
MONITORING & REMOTE CONTROL FEATURES
- ACTIVE MONITORING – Alerts to problems that need immediate attention
- REMOTE CONTROL – Allows adjusting of comfort and settings from anywhere using a mobile device
- SERVICE ALERTS – Sends routine maintenance reminders
- AIR FILTER MONITORING – Detects when it’s time to replace the air filter
- ALARM HISTORY – Displays time-stamped alarm codes with clear descriptions
GENERAL TERMS OF LIMITED WARRANTY
- Fujitsu General America, Inc. will furnish a replacement for any part of this product that fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty.
- For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts
(Registration Required)……………………………… Ten (10) Years
Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. “In keeping with its policy of continuous progress and product improvement, Fujitsu reserves the right to make changes without notice.”
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>