metabo Basic 250-24 W Compressor without Oil
Product Information
The product is a range of air compressors that includes Basic 250-24 W, Basic 250-24 W OF, Basic 250-50 W, Basic 250-50 W OF, and Basic 280-50 W OF models. The compressors are manufactured by Metabo and have different specifications such as power, voltage, and frequency. The compressors have IP 20 protection and come with different cable lengths. They have a maximum temperature of +40°C and a minimum temperature of +5°C. The compressors require oil for lubrication.
Product Usage Instructions
-
Read the user manual carefully before using the air compressor.
-
Wear protective gear such as safety glasses when using the air compressor.
-
Screw the provided air filter (11) onto the air intake (refer to Image C on page 3).
-
Ensure that the condensate drain (3) is closed.
-
Connect the air compressor to the power supply.
-
Adjust the pressure regulator (7) to set the desired pressure.
The current pressure is displayed on the pressure gauge (6). -
Use the air compressor with the appropriate air tools.
-
Perform regular maintenance on the air compressor. This
includes checking oil levels, changing oil, cleaning the air filter, and checking for leaks.
Declaration of Conformity
We, being solely responsible: Hereby declare that these compressors, identified by type and serial number 1), meet all relevant requirements of directives 2) and standards 3). issuing testing authority 4), measured LWA(M) / guaranteed LWA(G) sound power level 5), technical documentation for 6) – see page 4.
Specified Use
This tool is used for the generation of compressed air for professional tools
powered by compressed air.
The use in the medical and food sector as well as refilling of oxygen tanks is
not permitted.
Explosive, flammable or harmful gases must not be aspirated. Operation in
potentially explosive rooms is not permitted.
Any other use does not comply with the intended purpose. Unspecified use,
modification of the pump or use of parts that have not been tested and
approved by the manufacturer can cause unforeseeable damage!
Children, adolescents and untrained persons must not use the machine and the
connected compressed air tools.
Operate the device only unter supervision.
General Safety Instructions
WARNING – Reading the operating instructions will reduce the risk of injury.
General Safety Instructions
WARNING – Read all safety warnings and instructions. Failure to follow all
safety warnings and instructions may result in electric shock, fire and/or
serious injury.
Save all safety warnings and information for future reference! Pass on your
power tool only together with these documents. You and all other users must be
able to inform yourselves at any time.
Work area safety
-
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
-
b) Do not operate the device in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Tools create sparks that may ignite the dust or fumes.
-
c) Keep children and other persons away while operating the device.
Electrical safety -
a) Tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) tools. Unmodified plugs and matching outlets will reduce risk of electric shock.
-
b) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
-
Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
-
d) Do not abuse the cord. Never use the cord for carrying, hanging or unplugging the tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.
-
e) When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
Personal safety -
a) Stay alert, watch what you are doing and use common sense when operating a tool. Do not use a tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury.
-
b) Use personal protective equipment. Always wear eye protection. Protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection, depending on the type and application of the tool, will reduce personal injuries.
-
c) Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents.
-
d) Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
-
e) Do not overreach. Keep proper footing and balance at all times. This enables better control of the tool in unexpected situations.
-
f) Wear appropriate clothing. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts.
-
h) Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles. A careless action can cause severe injury within a fraction of a second.
Tool use and care -
a) Do not force the power tool. Use the correct tool for your application. The correct tool will do the job better and safer at the rate for which it was designed.
-
b) Do not use the tool if the switch does not turn it on and off. Electrical devices that can no longer be switched on or off are dangerous and must be repaired immediately.
-
c) Disconnect the plug from the power source and/or the battery pack from the tool before making any adjustments, changing accessories, or storing tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
-
d) Store idle tools out of the reach of children. Do not allow persons unfamiliar with the device or these instructions to operate the device. Devices are dangerous when used by inexperienced personnel.
-
e) Maintain power tools and accessories with care. Check that the moving parts are functioning properly and do not jam, that there is no breakage of parts or any other condition that may affect the device’s operation. If damaged, have the device repaired before using. Many accidents are caused by poorly maintained power tools.
-
g) Use the power tool, accessories, tool bits etc. in accordance with these instructions. Take into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.
-
h) Keep handles and grasping surfaces dryclean and free from oil and grease. Slippery handles and grasping surfaces do not allow safe handling and control of the tool in unexpected situations.
Service
-
a) Have your device serviced by a qualified repair person using only genuine replacement parts. This will ensure that the device functions safely.
Additional Safety Instructions -
These operating instructions are intended for people with basic technical knowledge in handling machines such as the one described here. If you have had no experience with machines of this kind, you should initially work under the supervision of people with previous experience.
-
The manufacturer bears no liability for damage caused by non-compliance with these operating instructions.
Information in these operating instructions is designated as shown below:-
Danger!
Risk of personal injury or environmental damage. -
Risk of electric shock!
Risk of personal injury from electric shock. -
Caution!
Risk of material damage.
-
Special Safety Instructions
The following residual risks basically exist for compressed air tools and
cannot be remedied completely even with safety installations:
Danger of injury due to escaping compressed air and parts, which are carried
along by compressed air!
-
Never direct compressed air on people or animals.
-
Ensure that all compressed air tools and accessories used are designed for the working pressure or can be connected via a pressure reducer.
-
When loosening the quick coupling pay attention that the compressed air contained in the compressed air hose escapes suddenly. Therefore get a firm grip of the end of the compressed air hose to be loosened.
-
Ensure that all screwed connections are always tightened properly.
-
Do not attempt to repair the pump yourself! Only professionals may carry out repairs on compressors, compressed containers and compressed air tools.
Danger from compressed air containing oil! (Basic 250-24 W, Basic 250-50 W) -
Use compressed air-containing oil exclusively for compressed air tools, which are designed for compressed air-containing oil.
-
Use a compressed air hose for compressed air-containing oil not for compressed air tools, which are not designed to be used with compressed air-containing oil.
-
Do not fill any car tyres etc. with compressed air containing oil.
-
Oil particles can be removed from the compressed air by means of appropriate filters. This permits the use of an oil-lubricated compressor even for compressed air tools requiring oil-free compressed air.
4.3 Risk of burns at the surfaces of the parts bearing compressed air! -
Let the tool cool down prior to the servicing work.
Risk of personal injury and crushing by moving parts! -
Do not operate the tool without installed guards.
-
Keep in mind that the tool starts up automatically when the minimum pressure is reached! – Ensure the tool is disconnected from power before servicing.
-
Ensure that when switching on (e.g. after servicing) no tools or loose parts are left on or in the tool.
Hazard generated by insufficient personal protection gear! -
Wear hearing protection.
-
Wear protective goggles.
-
Wear a breathing mask for applications generating dust or when harmful gases, mist or vapours are generated.
-
Wear suitable work clothes.
-
Wear non-slip footwear.
Hazard generated by tool defects! -
Keep tool and accessories in good repair. Observe the maintenance instructions.
-
Prior to each use check the tool for any eventual damage: Before continuing to use the tool, safety devices, protective devices or lightly damaged parts must be carefully inspected for correct and proper operation. A damaged device must only be reused after it has been correctly repaired.
-
Check to see that all moving parts work properly and do not jam. All parts must be correctly installed and fulfil all conditions necessary to ensure perfect operation of the unit.
-
Damaged protection devices or parts must be repaired or replaced by a qualified specialist.
Additional Safety Instructions -
Please also observe the special safety instructions in the respective chapters.
-
Observe any particular health and safety or accident prevention regulations governing the use of compressors and compressed air tools.
-
Observe the legal provisions for the operation of systems requiring monitoring.
-
Keep in mind that escaping condensate and other consumables contaminate the surrounding area and may trigger damage to the environment during operation and storage of the tool.
-
Consider environmental conditions:
Symbols on the machine (depends on model)
Safety devices
Safety valve
The spring-loaded valve (4) reacts if the permitted maximum pressure is
exceeded.
Overview
- compressor
- pressure vessel
- condensate outlet
- safety valve
- connection for compressed air (quick coupling), regulated compressed air
- manometer control pressure
- pressure regulator
- manometer boiler pressure
- ON/OFF Switch
- motor protection switch *
- air filter/air filter housing
- oil sealing plug *
- oil inspection glass *
- oil discharge plug *
- transport handle *
depends on model/equipment
Commissioning
Assembly (depending on model)
- Mount the tyres as shown (see fig. A, page 3).
- Mount the rubber feet as shown (see fig. B, page 3).
- Screw the enclosed air filter (11) onto the air inlet (see fig. C, page 3).
Check the condensate outlet Ensure that the condensate outlet (3) is closed.
Fill oil (Basic 250-24 W, Basic 250-50 W)
Oil quality and quantity (approx. details) see
Chapter 12. Technical data.
- Unscrew the oil plug (12) .
- Fill oil until the centre of the oil inspection glass (13) or the marking.
- Screw back in (12) the oil plug.
Installation
The positioning site of the device has to meet the following requirements:
- Dry, protected from frost
- Stable, horizontal and even surface
Operation
Power-supply connection
Danger! High voltage.
Operate the device in dry surroundings only.
Operate the device only at a power source meeting the following requirements:
Wall sockets installed according to regulations, earthed and tested; fuse
protection according to the technical data.
Position power supply cable so it does not interfere with the work and is not
damaged.
Check every time if the device is switched off, prior to plugging the mains
plug into the socket outlet.
Protect power supply cable from heat, aggressive liquids and sharp edges.
Use only extension cables with sufficient core cross-section (see chapter 12.
Technical Data).
Use extension cables for outdoor areas. When working outdoors, only use the
correspondingly marked extension cable approved for this purpose.
Do not switch off the compressor by pulling the mains plug, but use the ON/OFF
switch.
Always install an RCD with a maximum trip current of 30 mA upstream.
Generate compressed air
-
Switch on the device using the ON/OFF switch
(9) and wait, until the maximum boiler pressure has been reached (compressor switches off). The boiler pressure is shown at the boiler pressure manometer (8).
Set the control pressure at the pressure reducer (7) . The current control pressure is shown at the control pressure manometer (6) .
Attention!
The set control pressure must not exceed the maximum operating pressure of the connected compressed air tools! -
Connect the compressed air hose at the compressed air inlet (5) .
-
Connect the compressed air tool. Now you can work with the compressed air tool.
-
Switch off the tool if you don’t want to continue working immediately. Afterwards, pull the mains plug.
-
Drain the condensed water of the pressure vessel at the condensate outlet (3) on a daily basis.
Care And Maintenance
Danger!
Prior to all servicing:
Switch machine off. Disconnect the mains plug. Wait until the device has
stopped. Ensure that there is no more pressure on the device and all used
compressed air tools and accessories.
Leave the device and all used compressed air tools and accessories to cool
down.
After to all servicing:
Put back into operation and check all safety installations. Ensure that there
are no tools or similar at or in the device.
Repair and maintenance work other than that described in this section should
only be carried out by qualified specialists.
Important information
Maintenance and test have to be planned and carried out in accordance with the
legal provisions in line with the setup and mode of operation of the device.
Regulatory authorities may ask to view respective documentation.
Regular maintenance
Prior to every start
- Check compressed air hoses for damage and replace, if necessary.
- Check that all screw fittings are seated securely, and tighten if necessary.
- Check connection cables for damage, and, if necessary, have it replaced by a qualified electrician.
Daily
Drain the condensed water of the pressure vessel at the condensate outlet (3).
Every 50 hours of operation
The tank must be pressurized (preferably at least 80 % of the maximum
pressure). Turn the knurled screw of the safety valve (4) by hand in an anti-
clockwise direction until you can clearly hear compressed air escaping. Close
the safety valve (4) again, tighten the knurled screw by hand in a clockwise
direction until the stop. If no compressed air escapes even when the safety
valve is completely open, switch off the compressor and do not continue to
operate for safety reasons! Have the safety valve (4) replaced, see chapter 9.
Repairs.
-
Clean air filter (11) (see fig. D, page 3).
-
(Basic 250-24 W, Basic 250-50 W) Check the oil level of the compressor at the inspection glass (13), if necessary refill oil. (See chapter 6.)
Every 250 hours of operation -
Clean air filter (11) or replace (see fig. D, page 3).
Every 500 hours of operation -
(Basic 250-24 W, Basic 250-50 W) Completely drain the oil at the oil outlet plug (14) and replace. (See chapter 6.)
Every 1000 hours of operation -
Have an inspection carried out in an authorized service centre. This significantly increases the service life of the compressor.
Storage of device
- Switch off the device and pull mains plug.
- Depressurize the pressure vessel and all connected compressed air tools.
- Drain the condensed water of the pressure vessel at the condensate outlet (3).
- Store the device in such a way that unauthorized persons cannot start it.
- (Basic 250-24 W, Basic 250-50 W) Do not place the device on its side. Oil might leak!
Repairs
Danger!
Repair of tools must be carried out by qualified electricians only!
If you have Metabo devices that require repairs, please contact your Metabo
service centre. See www.metabo.com for addresses.
You can download a list of spare parts from www.metabo.com.
Environmental Protection
Danger!
The condensed water from the pressure vessel contains oil residue and /or
contaminations hazardous to the environment. Dispose of the condensed water in
an environmentally-friendly manner using respective collection sites!
Danger!
(Basic 250-24 W, Basic 250-50 W) Dispose of the old oil from the compressor in
an environmentally-friendly manner using respective collection sites.
Observe national regulations on environmentally compatible disposal and on the
recycling of disused machines, packaging and accessories. Only for EU
countries: Never dispose of devices in your household waste! In accordance
with European Guideline 2012/ 19/EU on used electronic and electric equipment
and its implementation in national legal systems, used devices must be
collected separately and returned for environmentally compatible recycling.
Troubleshooting
Danger!
Prior to all servicing:
Switch machine off. Disconnect the mains plug. Wait until the device has
stopped. Ensure that there is no more pressure on the device and all used
compressed air tools and accessories. Leave the device and all used compressed
air tools and accessories to cool down.
Any works other than the ones described in this chapter, must be carried out
only by a qualified electrician or the service branch in your country.
After to all servicing:
Put back into operation and check all safety installations. Ensure that there
are no tools or similar at or in the device.
Compressor does not run:
-
No mains voltage.
- Check cables, plug, outlet and mains fuse.
-
Mains voltage too low.
- Use only extension cables with sufficient core cross-section (see chapter 12. Technical Data). For cold device: Avoid extension cable. For cold device: Depressurise the pressure vessel.
-
Compressor was switched off by pulling the mains plug while it was running.
- First, switch off the compressor using the ON/OFF switch (9), then switch on again.
-
Motor overheated, e.g. due to insufficient cooling (cooling ribs covered).
-
Switch off the compressor using the ON/OFF switch (9) .
-
Remedy the cause for overheating. Leave to cool for about ten minutes.
-
Only model with motor protection switch (10): Check motor protection switch (10) , if required, reset by pressing it. (see fig. E, page 3).
-
Switch on the compressor again using the ON/OFF switch (9) .
The compressor runs without building up sufficient pressure. -
Condensate outlet leaking.
- Ensure that the condensate outlet (3) is closed.
- Check the seal of the drainage plug, if required, replace.
-
Check valve leaking.
- Have check valve serviced in authorized service center.
The compressed air tool does not get enough pressure.
- Have check valve serviced in authorized service center.
-
Pressure controller not open enough.
- Open pressure controller (7) further.
-
Hose connection between the compressor and compressed air tool leaking.
- Check hose connection; if required replace damaged parts.
Technical Data
Explanatory notes on the specifications on page 3. Changes due to technological progress reserved.
-
A =suction capacity
-
F =filling capacity
Leff =Effective output volume at 80% max. pressure -
p =max. pressure
-
V =vessel size
-
a =number of air outlets
-
z =number of cylinders
-
n0 =max. speed
-
P1 =rated input power
-
U =connection voltage
-
I =rated power
-
Fmin =min. fuse protection
-
IP =protection class
-
G =maximum overall length and core crosssection of extension cables
-
A =dimensions (lxwxh)
-
Tmax =max. storage / operating temperature *
-
Tmin =min. storage/operating temperature **
-
Oel =oil quantity and quality for oil change (depends on model)
-
m =weight
-
- = The service life of some components e.g. seal in check valve is significantly reduced, if the
compressor is operated at high temperatures
(max. storage / operating temperature and higher).
** = At temperature below the min. storage/operating temperature, there is a
danger of frost for the condensate in the pressure vessel.
The technical specifications quoted are subject to tolerances (in compliance
with the relevant valid standards).
Emission values
These values make it possible to assess the emissions from the device and to
compare different devices. The actual load may be higher or lower depending on
the operating conditions, the condition of the device or the accessories.
Please allow for breaks and periods when the load is lower for assessment
purposes. Arrange protective measures for the user e.g. organizational
measures based on the adjusted estimates.
Typical A-effective perceived sound levels:
LpA = sound-pressure level
LWA = acoustic power level
LWA(G) = gua2000/14rant /ECeed acoustic power level as per KpA,
KWA=uncertainty
Information on the nameplate:
- A Manufacturer
- B Item, version, serial number
- C Machine designation
- D Connection voltage/frequency
- E Rated input power
- F Rated power/protection type
- G Max. speed
- H Max. pressure
- I CE mark – This machine conforms to the EC directives as per the Declaration of Conformity
- J Year of manufacture
- K Suction capacity
- L Filling capacity
- M Compressor speed
- N Number of cylinders
- O Boiler size
- P Disposal symbol (see chapter 10.)
Metabowerke GmbH
Metabo-Allee 1
72622 Nuertingen
Germany