tracer AT-6000 Digital Breath Alcohol Tester Instruction Manual

October 26, 2023
Tracer

tracer AT-6000 Digital Breath Alcohol Tester

Top 10 Best Mouse for Your Computer

Top 10 Best Mouse for Your Computer

tracer -AT-6000-Digital-Breat-Alcohol-Tester-PRODUCT

INSTALLATION

tracer -AT-6000-Digital-Breat-Alcohol-Tester-FIG1

  1. Mouthpiece (replaceable)
  2. Buzzer hole
  3. Power button
  4. Battery compartment
  5. LCD screen
  6. Imbedded Cover for Mouthpiece

Reference
BAC: Blood Alcohol Concentration BrAC: Breath Alcohol Concentration
0.03% BACrefers to there is 0.03g alcohol in each
100ml of blood 0.30%o BAC — refers to there is 0.30g alcohol in each
1000ml of blood

Features

  • ho-bit digital alcohol tester
  • Three kinds of unit conversion (%BAC I %oBACI mg/L)
  • Built-in Mouthpiece, Mouthpiece can be replaced
  • Both sides of the products can be installed with Mouthpieces
  • Blue backlit digital LCD screen
  • Lightweight stylish design, patented product
  • Loud alarm sounds

Installation battery

  • Open the back cover
  • Place 3 pieces of (AAA) alkaline batteries by following the positive and negative pole instructions.
  • Install the back cover.

How to use the alcohol tester – Warm-up

  • Press the power button for a second, and after a sound of, tick”, the tester’s LCD screen will start up.
  • Warm up, Warm-up” will appear on the screen, then under the Warm-up mode, will start to countdown from 15 to 00.

Note
There are often a number of gases or debris attached to the sensor surface of the tester. Therefore, when you removed the tester from its packaging for the first time, or you have used it for a long time, you need some time to clean and warm up the sensors. If possible, users need to push the power button as many as possible times.
Testing
After a successful, Warm-up”, a , Blow” logo will appear on the screen. Under the test mode, it will start to countdown from 10 to 00.  Hold the Mouthpiece in your mouth, and blow with the normal intensity for 2-3 seconds. It was recommended that users shall start to blow when the countdown is beginning from 09 seconds so that there is sufficient time for the tester to absorb their breath.
Readings

  1. When the display is more than 0.050% BAC or 0.500%o BAC or 0.250mg/L (BrAC), the tester will send an alarm.
  2. Unit conversion: under the test result mode, hold down The, Power button to change the units (%BAC/ %oBAC / mg/L), the final displayed units will be the units for the next test.

Auto power off
Test results will display about 20 seconds on the LCD, and then the
tester will automatically switch off.
Replace mouthpiece
Take a mouthpiece out of the nozzle box in the back, and mount it on the
left or the right side of the tester according to your own preferences.
Replace battery
LCD screen flashes for low power, please replace the alkaline batteries.

Specifications

  • Sensor: high-precision semiconductor alcohol sensor Detection range:
  • 0.000 0.199% BAC; 0.000 1.990%o BAC;
  • 0.000 0.995mg/L (BrAC) Alarm point: 0.050% BAC; 0.500%% BAC
  • 0.250mg/L (BrAC) Accuracy: 0.010% BAC; t0.100%o BAC; 0.050mg/L
  • Response Time: <5s
  • warm-up time: <20s Operating voltage:
  • 3x “AAA alkaline battery Operating current: $120mA Operating
  • environment: -10°C ~ 50°C Screen: blue backlight 3-digit LCD screen

Precaution

  • Take a test at least 20 minutes after drinking, as it will take about 20 minutes for alcohol to be absorbed from the digestive system into the bloodstream. Take the test immediately after drinking, the results will only reflect the alcohol concentration in your mouth, rather than the alcohol concentration contained in the blood.
  • To enable accurate test results, please take the test 20 minutes after drinking, preferably, the testing time shall be more than 3 minutes after the last test.
  • Do not clean the tester with direct use of chemicals or fluid containing dissolved corrosive matters, to avoid the liquid being blown into the inflatable tube.
  • If the rudimental air in the tester is very thick, the next test result will not be displayed, please shake slightly for several times so that the inside air can be volatilized out
  • If the test is under low voltage, there will be some deviation between the test values and real values.
  • Is strictly prohibited that the tester be placed and used in a closed environment with paint, pesticides, alcohol, and other corrosive gases or polluted air.
  • Unauthorized repairs and damages to internal parts will lead to product failure.
  • After being used for a long time, there may be dirt on the tester, clean it with a cloth.

Declaration
Regardless of whether the product is used, manufacturers and vendors will not bear any responsibility for the violations. For example drunk driving and high-altitude operations driving. Each person reacts differently to alcohol, so the test results are for reference only, which cannot serve as the criteria in determining the outcome.
Patent No.: ZL200830154590.9

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals