ACME BL-200 CW Stage Blinder IP User Manual
- June 4, 2024
- acme
Table of Contents
- ACME BL-200 CW Stage Blinder IP
- Safety Instructions
- Technical Specifications
- Installation and Connection
- How to set the unit
- How to control the unit
- DMX512 configuration
- DMX512 Connection
- Error Information
- Troubleshooting
- Fixture Cleaning
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ACME BL-200 CW Stage Blinder IP
Safety Instructions
Please read the instruction carefully which includes important information about the installation, usage and maintenance.
- Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
- Please unpack and check carefully there is no transportation damage before using the fixture.
- Please disconnect main power before servicing and maintenance.
- The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
- The maximum ambient temperature is Ta: 40℃. DO NOT operate it where the temperature is higher than this.
- DO NOT connect the device to any dimmer pack.
- The housing must be replaced if they are visibly damaged.
- Unit surface temperature may reach up to 60℃. Don’t touch the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
- There are no user serviceable parts inside the fixture. Do not open the housing or attempt any repairs by yourself. In the unlikely event your fixture may require service, please contact your nearest dealer.
- In the event of serious operating problem, stop using the fixture immediately. Never try to repair the fixture by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.
For AC 220-240V power supply, the maximum fixtures that can be connected on
one power cable is 8(including the first fixture) ;
For AC 100~120V power supply, the maximum fixtures that can be connected on
one power cable is 4 (including the first fixture).
Technical Specifications
- 4 channel Mode switchable : 6CH/7CH/10CH/HSIC Channel Modes;
- Dimmer, Strobe;
- Ideal for Professional stages, Concerts, clubs, discotheques, Mobile DJs, etc.
- Input Voltage: 100-240V~ 50/60Hz
- Total Power consumption: 235W
- Beam Angle:
- IP Grade:
- LED Sources: 37° IP X4
- TX-5260RGBW150C33
- Dimension/Weight:
- 534 x 281 x 224mm, 4.5Kg
- 21″x11″x8.8″in, 9.9lbs
Installation and Connection
The unit should be mounted via its screw holes on the bracket. Always ensure
that the unit is firmly fixed to avoid vibration and slipping while operating.
Always ensure that the structure to which you are attaching the unit is secure
and is able to support a weight of 10 times of the unit’s weight. Also always
use a safety cable that can hold 12 times of the weight of the unit when
installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place
where is out of the touch of people and has no one pass by or under it. The
unit should be mounted in the height of 0 to 30m. Hanging with Hanging bracket
Fixture Jointing (Between two fixtures)
Hanging with Big hanging bracket (Optional)
Fixture jointing (Between more than two units) Warning: Max. load≤10 fixtures vertical.
How to set the unit
Rear Panel
-
DMX input/output:
For DMX512 link, use 3-pin/5-pin XLR plug cable to input DMX signal, and to link the next unit. -
LED indicator:
POWER| On| Power On
---|---|---
DMX| On| DMX input present -
Button:
MENU| To select the programming functions
---|---
DOWN| To go forward in the selected functions
UP| To go backward in the selected functions
ENTER| To confirm the selected functions -
Display: Show the various menus and the selected functionsï¼›
-
Mains input/output::Use Powercon true one mains connection.
Main Function
To select any functions, press MENU button until the required one is shown on the display. Select the function by ENTER button. Use DOWN and UP button to change the mode. Once the required mode has been selected, press ENTER button to setup or it will return to the main functions without any change after idling 30 seconds automatically. Back to the functions without any change press MENU button. The main functions are shown below:
-
DMX 512 Address Setting
Select the , press the ENTER button and the display will blink. Use the DOWN and UP button to change the DMX 512 address(001-512). Once the address has been selected, press the ENTER
button to setup or exit menu mode without any change after 30 seconds automatically. Back to the previous functions without any change press the MENU button. -
Channel Mode
Select the , press the ENTER button. Use the DOWN and UP button to select the channel mode (6 Channel Mode), (7Channel Mode), (10 Channel Mode), (HSIC Channel Mode). Once selected, press the ENTER button to setup or exit menu mode without any change after 30 seconds automatically. To go back to the functions without any change press the MENU button -
Dimmer Mode
Select the , press the ENTER button. Use the DOWN and UP button to select (Dimmer Mode 4). Once selected, press the ENTER button to setup or exit menu mode without any change after 30 seconds. Back to the functions without any change press the MENU button again.
Mode 1(Optically Linear): The increase in light intensity appears to be linear
as DMX value is increased.
Mode 2(Square Law): Light intensity control is finer at low levels and coarser
at high levels.
Mode 3(Inverse Square Law): Light intensity control is coarser at low levels
and finger at high levels.
Mode 4(S-cure): Light intensity control is finger at low levels and high
levels and coarser at medium levels.
-
Dimmer Speed
Select the , press the ENTER button. Use the DOWN and UP button to select (Smooth). Once selected, press the ENTER button to setup or exit menu mode without
any change after 30 seconds. Back to the functions without any change press the MENU button again. -
DMX State
Select the , press the ENTER button. Use the DOWN and UP button to select button to setup or exit menu mode without any change after 30 seconds. Back to the functions without any change press the MENU button again. -
LED Display
Select the , press the ENTER button. Use the DOWN and UP button to select (LED display off, after 30 sec. without any move, display will off again). Once selected, press the ENTER button to setup or exit menu mode without any change after 30 seconds automatically. Back to the functions without any change press the MENU button again. -
Display Inverse
Select the , press the ENTER button. Use the DOWN and UP button to select (Display mode without any change after 30 seconds automatically. Back to the functions without any change press the MENU button again. -
Auto Test
Select the , press the ENTER button and the unit will run self-test by built- in program. To go back to the functions press the MENU button again. Hold and press the MENU button about one second or wait for one minute to exit the menu mode. -
Temperature Display
-
Select the , press ENTER button and the display will show the temperature of each unit . To go back to the functions press the MENU button.
-
Fixture Hour
Select the , press ENTER button and the display will show the number of working hours of the unit. To go back to the functions press the MENU button. -
Factory Setting
Select the , Use the DOWN and UP button to select YES,, fixture will restore factory settings.. To go back to the functions press the MENU button.
How to control the unit
- By DMX controller;
No need to turn the unit off when you change the DMX address, as new DMX address setting will be affected at once. Turn on the unit, under the DMX signal , the LED will display the saved channel address (001-512).
DMX512 configuration
DMX512 Connection
- Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” cable. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system
- The DMX output and input connectors are pass-through to maintain the DMX circuit when one of the units’ power is disconnected.
- At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
- Each lighting fixture needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
- 3/5 pin XLR connectors:. 3/5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
Error Information
Error code
Err1| CPU-B ERROR Check whether the communication plug is loose / detached Check whether the PCB related circuits are damaged
Err2
| Temperature Error Check whether the test lead is in good contact and disconnected, and check whether the thermistor is broken Check whether the PCB related circuits are damaged
Troubleshooting
Following are a few common problems that may occur during operation. Here are
some suggestions for
easy troubleshooting:
- A. The fixture does not work, no light
- Check the connection of power and main fuse.
- Measure the mains voltage on the main connector.
- B. Not responding to DMX controller
- DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
- If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
- If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the previous one.
- Try to use another DMX controller.
- Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit.
Fixture Cleaning
The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics.
- Clean with soft cloth using normal glass cleaning fluid.
- Always dry the parts carefully.
- Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>