Lexman LX-M-101 Non-Contact Pocket Voltage Tester Pen User Guide
- October 30, 2023
- lexman
Table of Contents
Lexman LX-M-101 Non-Contact Pocket Voltage Tester Pen
Pocket voltage tester pen NCV LX4å-101
User guide
EAN CODE : 3276007463729
Safety Information
Safety Symbols Table
- indoor use
- Protection will be impaired if used in a manner not specified in this instruction.
- POLLUTlON DEGREE 2
- Attitude: 2000 m
Waming: To avoid possible electric shock or personal injury:
Please read the instruction manual carefully before use and strictly observe
the safety rules and warnings listed in the instruction manual.
- It the Voltage Detector is not used according to the instructions the protection function provided by the NCVD (Non-Contact voltage detector) may be affected and invalidate any warranties.
- Do not use if the LED display is not illuminated green when switched on.
- Before using the Voltage Detector, always test on a known power supply to onsuro it’s in good working condition.
- When using the Voltage Detector, if the tip does not illuminate or no beeping sound.voltage could still be present. Voltage Detector indicates active voltage in tho presence of electrostatic fields of sufficient strength generated from the source (Mains)voltage. If the field strength is weak the Voltage Detector may not provide indication of live voltages. The existence of voltage may be affected by several factors including but not limited to shielded wires / cables, thickness and type of insulation, distance from voltage source, differences in socket design / recessed sockets, condition of the Voltage Detector and batteries. • Always chock tho Voltage Detector before use to ensure there is no damage. Never use the equipment if any parts are damaged.
- Do not use tho detector on voltage exceeding the marking on the Voltage Detector.
- Do not use tho detector on voltage exceeding the marking on the Vottage Detector.
- Extra care should be taken when working with voltages above 30V, due to the risk of electric shock.
Limited warranty
5 years warranty against any manufacturing defects or faulty workmanship, This warranty does not cover fuses, disposable batteries or damage from accident, neglect. misuse, alteration, contamination or abnormal conditions of operation or handling.
Specification
- Operating voltage: AC Voltage: 12—1000V (50/60Hz)
- High Sensitivity: 12 – looov
- Middle sensitivity: 48 – 1000V
- Low Sensitivity: distinguish the Live & Neutral
- CAT 111 looov
Application Environment:
- Operating 0—400C.
- Storage Temperature: -10-500C
- Humidity: 85%
- Battery: 2 x 1.5V AAA
Product Introduction
Battery Replacement
- Rotate the battery cover anti-clockwise then remove the old batteries.
- Install the new batteries according to the positive and negative instructions on the underside of the detector.
Waming: To avoid electric shock, the battery cover should always be replaced before checking any voltage.
Operation
Tum NCVT Functionality On:
- Press and release the POWER / SEN button
- Listen for single-beep sound and watch tor tho green LED to illuminate and remain lit illuminate and remain lit indicating the unit is on.
Turn NCVT Functionality Off:
- Hold and roloaso the POWER / SEN button
- Watch tor the green LED turn off,
AC Voltage Detection:
- prior to use, test on known live circuit to verify functionality,
- Place tip Of tester near AC voltage. If voltage is sensed. the unit will ornit audible boops and tho proximity sensor will indicate strength of detected.
Auto Power Off:
- After 155 secondes of non-use, the NCVT tester automatically powers off to conserve battery life.
- Upon Off, the unit emit a sound and the LED wili tum off,
Turn Flashlight On/Off:
Turn on the power first. then….
- Press and release Flashlight button to turn flashbght on or off. After 90s of non-use, tho flashlight will automatically off to conserve battery life.
Adjust Sensitivity:
- Press and release the POWER / SEN button and the detector power on. At the same time one LED on the sensitivity indication bar gragh light up to enter the LOW sensitivity.
- Press the POWER / SEN button two times and two LED light up to enter the MIDDLE sensitivity.
- Press the POWER / SEN button three and three LED light up to enter the HIGH sensitivity.
- The sensitivity returns to the low sensitivity when you use it again. For example, the sensitivity is HIGH during the first testing. When you on again to detect, the sensitivity will be the low sensitivity.
Suggestion of SENSITIVITY setting
- Please adjust to MIDDLE SENSITIVITY when tost tho voltage around of Home Appliance powered by AC 110V – AC 240V, such as refrigerator;
- Adjust to LOW SENSITIVITY to distinguish the LIVE and NEUTRAL wire;
- Adjust to HIGH SENSITIVITY to test the voltage around the product powered under AC 48V.
Low Battery Indication:
- When the battery drops to approximately 2.4V, the green LED will turn red LED.
- When the battery drops to approximately 2.1V, the detector will automatically power Off,
Electrical products must not dispose of out with domestic waste They must take to a communal collecting for environmentally friendly disposal in accordance with focal, Contact your bcai homes or stockist for advice on teaching, The packaging material is recßable. Dispose of the packaging jn an environmentally friendly manner and make It available for recyclable materials collection-seme Don’t throw batteries or out of Oder products Mth the household waste (garbage). The dangerous substances that they are Ikety to milde may harm health or the environment Make your retail take back these ar use the seJectve cooed of garage imposed by yur aty.
Made in CHINA