FS S3400-48T4SP PoE Managed Switch User Guide
- October 30, 2023
- FS
Table of Contents
FS S3400-48T4SP PoE Managed Switch
S3400-48T4SP Switch
ERPS Configuration Guide
The S3400-48T4SP switch is a product that supports Ethernet ring protection
protocol. It allows for the configuration of a switch into nodes of multiple
physical ring networks to form tangent
rings. The ring protection protocols do not support intersecting rings with
common links. ERPS (Ethernet Ring Protection Switching) is a protocol used to
protect Ethernet rings from failures. This guide provides instructions on how
to configure ERPS on the S3400-48T4SP switch.
Chapter 1: Introduction to Fast Ethernet Ring Protection
Overview
The company’s ring network protection protocol supports the configuration of a switch into nodes of multiple physical ring networks to form tangent rings. Ring protection protocols do not support intersecting rings with common links.
ERPS Related Concepts
ERPS supports multi-loop or hierarchical transport network topology. The
main ring is a complete single ring, and the sub-loop is connected to the main
loop (or sub-loop) through two
interconnected nodes (interconnection-node). Each switch that forms the ring
network is a ring network node. There are four kinds of ring network node
roles: RPL protection node, RPL neighbor node, interconnected node
(interconnection-node), and common node (node).
The ERPS port configuration monitors the state of its ring network link
through the down mep, and the ring network port of the interconnected node
accessing the sub-ring also has to configure the up mep to monitor the
connectivity on the main ring.
Chapter 2: ERPS Configuration
ERPS Configuration Notes
Before configuring ERPS, make sure that the network topology is a ring, and
the switches are interconnected as per the topology.
Identify the RPL protection node and RPL neighbor node on each ring network.
Ensure that the ERPS port configuration is monitored through the down mep, and
the ring network port of the interconnected node accessing the sub-ring also
has to configure the up mep to monitor the connectivity on the main ring.
ERPS Configuration Tasks
The following are the steps to configure ERPS on the S3400-48T4SP switch:
- Enable ERPS on the switch.
- Configure ERPS on each ring network.
- Identify the RPL protection node and RPL neighbor node on each ring network.
- Configure the ERPS port on each switch.
- Configure the MEP (Maintenance End Point) on the ring network port.
- Configure the virtual ports of interconnected nodes on Up MEP ports.
Reference: For more information and detailed configuration steps, refer to the S3400-48T4SP Switch ERPS Configuration Guide available at www.fs.com.
Introduction to Fast Ethernet Ring Protection
Overview
The fast Ethernet protection protocol is a kind of special link layer
protocol, which is used to construct the ring-like Ethernet topology. Ethernet
protection protocol blocks a link in the case of complete topology of the ring
network to prevent the occurrence of data loops to form a broadcast storm. In
the case of link interruption, the protocol quickly recovers the previously
blocked link, so that the communication between the nodes of the ring network
is restored. Fast loop protection protocol ensures that data packets can be
sent to the correct link when topology changes by controlling the aging of
switch MAC address table. generally, the aging time of MAC address in address
table is 300 seconds. a ring network protection protocol can control MAC aging
of the switch address table in a very short time. both ring protection
protocol and spanning tree protocol are used for link layer topology control.
the spanning tree protocol is suitable for various complex networks, which use
the hop-by-hop method to propagate network topology changes. The loop
protection protocol is dedicated to the loop topology and propagates the
topology change information using diffusion method. Therefore, in the ring
network, the convergence performance of the ring network protection protocol
is better than that of the spanning tree protocol. When the network is in good
condition, the time for the ring protection protocol to recover the network
communication can be less than 50 milliseconds.
Description: The company’s ring network protection protocol supports the configuration of a switch into nodes of multiple physical ring networks to form tangent rings. ring protection protocols do not support intersecting rings with common links.
ERPS Related Concepts
Figure 1: Example of ERPS Ethernet
Ring Network Level
ERPS support multi-loop or hierarchical transport network topology, as shown
in Figure 1. The main ring is a complete single ring, and the sub-loop is
connected to the main loop (or sub-loop) through two interconnected nodes
(interconnection-node), In Figure 1, The red line is the main ring, node S1、
link S1-S2、 node S2、 link S2-S4、 node S4、 link S4-S3、 node S3、 link S3-S1; The
blue line is a subring, node S3、 link S3-S5、 node S5、 link S5-S6、 node S6、
link S6-S4、 node but excluding link S4-S3.
Network Node Role
Each switch that forms the ring network is a ring network node. There are four
kinds of ring network node roles: RPL protection node, RPL neighbor node,
interconnected node (interconnection-node) and common node (Node).one physical
link is selected on each single loop as the RPL protection link, one of the
two switches directly connected to this link is used as the RPL protection
node, the other is used as the RPL neighbor node, and the remaining other
switches are used as ordinary nodes. and the interconnected node
(interconnection-node) is the two intersection nodes in which the sub-ring is
connected to the main ring (or sub-ring).
the S1 is the RPL protection node in the main loop, as shown in figure 1, S3
is the RPL neighbor node, while the S2 and S4 are the ordinary nodes; in the
subloop, the S6 is the RPL protection node, and is connected to the main loop
through the interconnected node (interconnection-node).
the node type of the ERPS protocol is mainly determined by the port role, but
the node type of the interconnected node (interconnection-node) needs to be
determined first when configured. by default, the node is not the
interconnected node (interconnection-node).
The function of the ring network node is basically the same: detect the state
of the local ring network port and give notice when the link fails. the
difference is that RPL protect nodes and RPL neighbor nodes normally block RPL
links, while ordinary nodes do not. the interconnected node (interconnection-
node) has only one ring-net port connected sub-rings, and the node must also
be a node on another main ring (or sub-ring).
Ring Network Port Role
ERPS protocol requires that each node has two ports connected to the ring
network, and each port is called the ring network port (Ring Port).
furthermore, on each single loop, there exists a ring network port as the ring
network protection link (RPL).For interconnected nodes (interconnection-node),
although there is only a loop network port connected subloop, there is also a
virtual port to detect the connectivity between the two interconnected nodes
(interconnection-node), which will be discussed later.
normally, all ring network ports on the ring network except the RPL link are
in the forwarding state, RPL the RPL ports of the protection node and the RPL
neighbor node are blocked to avoid the loop. RPL protect node and RPL neighbor
node to unblock the RPL port in case of ring network link failure to restore
network communication.
At one switch, only one RPL port can be configured for each ring node
instance.
Description: ERPS protocol supports configuring the aggregation port as a ring
network port.
ERPS and CFM
the ring network link is monitored MEP, the ERPS port configuration. the ring
network port monitors the state of its ring network link through the down mep;
the ring network port of the interconnected node accessing the sub-ring also
has to configure the up mep to monitor the connectivity on the main ring, as
shown in figure 2.
Figure 2: Virtual ports of interconnected nodes configured on Up MEP ports
In figure 2, all ERPS ring network ports are configured down mep, monitor ring network links through down mep, e.g. ring network links are configured on a ring network port C by nodes and nodes respectively down mep later monitored, the link fails or recovers from the failure, sends corresponding notifications to the ERPS control module; at the same time, the down mep is responsible for receiving and sending R-APS messages. up mep is only configured on the ring network port of the interconnected node to access the sub-ring to monitor the connectivity of the main ring. when the direct main ring path of the interconnected node is impassable or the communication is restored, the corresponding notification is sent to the ERPS control module. Moreover, the ring network port for an interconnected node to access a sub-loop is not only configured up mep, because it is also a ring network port, it is also configured down mep..
Description: An interconnected node connects to the ring network port of the sub-ring up mep is configured to monitor the connectivity of the main ring, which is equivalent to the virtual port to monitor the main ring link.
Connectivity Mode Using R-APS Virtual Channels
For a sub-loop, an interconnected node is a node that connects the sub-loop to
the rest of the network, as shown in Figure 1. the up mep port of the
interconnected node monitors the connectivity of the main ring, which is
called the R-APS virtual channel. by R-APS virtual channels, two
interconnected nodes can communicate R-APS through the rest of the network.
the sub-loop sends (and receives) R-APS information to the network via R-APS
virtual channel, while R-APS information can be transmitted in the network as
a data stream. Of course, R-APS information is to be distinguished from
ordinary data streams, so different control vlan are used to carry R-APS
information for different ERPS ring networks.
Of course, there is also a network state is the interconnection node in
connection with the sub-ring and the rest of the network, do not use the R-APS
channel, its R-APS channel state is the forwarding state.
R-APS Transmission VLAN
R-APS message is transmitted in a R-APS channel, so set up a VLAN.
specifically for the R-APS channel The different nodes set up different VLAN,
but for one node, the other nodes set up VLAN can be used as the VLAN. of
common data stream transmission When configuring a R-APS VLAN, if the VLAN is
not created, the ERPS system automatically creates the VLAN. for it
the state of the ERPS loop network port in the R-APS channel is consistent
with the state of the common data stream, except for the sub-loop that does
not use the R-APS virtual channel, because the R-APS channel of the
interconnected node on this sub-loop is aborted, so the node on the sub-loop
of the R-APS virtual channel is not used, and the state of its R-APS channel
is forwarding state.
Description: the VLAN of the MEP port where the ERPS port is located should be
consistent with the R-APS transmission.
Return Mode
For some ring networks, the network resources of the link channel in which the
data stream is normally transmitted will be better, while the RPL channel is
only used for backup, so the return mode is used to return the data stream
back to the channel with better network resources when switching and clearing.
And some ring networks, the requirements for network resources are not so
high, do not need to reverse the recovery immediately back to the original
link channel, so the use of non-return mode, but also reduce the number of
return switching.
During the return mode operation, when a switch is cleared, the data stream
returns to the original channel, blocking the RPL.. The return of the data
stream in the case of clearing the fault needs to be used to avoid protection
switching in the case of intermittent failure after the WTR timer timeout;
while the WTB timer needs to be waited in the case of clearing the manual or
forced switching command. and in non-return mode operation, when a switching
is cleared, the data stream will still be on the RPL channel as long as the
RPL channel is not faulty.
Description: WTR timer and WTB timer only take effect in return mode.
ERPS Message Type
ERPS type of message used by the protocol is shown in Table 2.1.
ERPS Type of message for the protection protocol
ERPS Ring Network Protection Mechanism
Stable State
the loop network protects the node from blocking the RPL port in a stable
state and continuously sends NR-RB protocol messages in a configurable period.
All common nodes that receive NR-RB messages set the local ring network port
as forwarding state. In stable state, the common node does not send the
protocol message.
the period of the NR-RB message sent by the protection node can be modified by
send-time node configuration command.
Local Link Failure Processing
Once a loop node detects a local link failure, it first de-blocking the local
un-failed port (including RPL port or normal loop port that has not yet
entered the forwarding state), then starts sending SF protocol messages and
aging the local MAC address table.
All other nodes that receive SF messages first stop sending local messages,
then unblock local un-failure ports, and aging address tables. The link
failure node continuously sends the SF message in the configured send-time
cycle. During this process, if the port of another node recovers from the
failure state, the node sets the recovery port to the forwarding state after
receiving the SF message.
Local Link Recovery Processing
If the loop node detects that the local loop network port recovers from the
failure state, it will maintain the blocking state of the port and start
sending NR messages continuously.
When a node receives a SF message from another node, which indicates that
there are other invalid links in the network, the local node stops sending NR
message and sets the restored port to forwarding state. when the local node
does not receive a new SF message, after the ring network protection node (RPL
node) receives the NR message, the switching recovery timer is started. after
the timer timeout, the RPL node re-blocking the RPL port, sending the NR-RB
message, and then the address table aging, the network communication is
restored to original stable state.
Protection of Switching —— Link Recovery
If the loop node detects that the local loop network port recovers from the
failure state, it will maintain the blocking state of the port and start
sending NR messages continuously.
When a node receives a SF message from another node, which indicates that
there are other invalid links in the network, the local node stops sending NR
message and sets the restored port to forwarding state.
When the local node does not receive the new SF message, the link recovery is
carried out after the network protection node (RPL node) receives the NR
message.but the behavior and function of return mode and non-return mode are
inconsistent when link recovery.
Return Mode
In return mode, the ring link is restored.RPL node receives the NR message, it
will start the switching recovery timer. after the timer timeout, the RPL node
re-blocking the RPL port, sending the NR-RB message, and then the address
table aging, network communication back to the initial stable state.
Non-return Mode
In non-return mode, the ring link does not automatically recover. RPL node
does not reply after receiving the NR message, and the other nodes do not do
any action after receiving the NR message. Only when RPL node receives the
Clear command will the RPL node block the link and continuously send NR RB
messages to the two ring network ports, then Flush FDB.Failure node receives
NR RB message to unblock the port.Network nodes perform FDB Flush. after
receiving NR RB message
Protection Switching —— Manual Switching
When a loop network node receives a manual switching command, it blocks the
data channel and the R-APS channel (blocking the port of one data channel and
R-APS channel), opens the other loop network ports, and continuously sends MS
messages to the two loop network ports, then Flush FDB.. The remaining ring
network nodes receive MS messages and open the data flow and R-APS channels
through the RPL. The ring network node that sends MS message stops sending MS
message after receiving the message.Network nodes perform FDB Flush. after
receiving MS message
The above actions completed a manual switching operation, in order to switch normal, there are several points to note:
- When a manual switching command already exists in the ring network, the subsequent manual switching commands are invalid. The node receiving the new switching command rejects the new switching command and notifies that manual switching is rejected.
- Local nodes that have generated manual switching commands should clear local manual switching commands and send NR messages if MS messages ID different nodes are received. At the same time, the node keeps blocking the ring network port blocked by the previous manual switching command.
- A node that has generated a manual switching command should clear the manual switching request and execute a higher priority request if a higher priority local request or message is received.
A node that performs a manual switching command clears the manual switching command after receiving the Clear command. A node keeps blocking the ring network port blocked by the previous manual switching command and continuously sends NR messages to both ring network ports. and the following link recovery, the behavior and function of return mode and non-return mode are inconsistent.
Return Mode
In return mode, the ring link is restored. RPL node receives the NR message
and starts the WTB timer. WTB the timer timeout, the RPL node blocks the link,
sends NR RB messages, and Flush FDB. them The rest of the ring network nodes
unblock all non RPL links after receiving the NR RB message, and then Flush
FDB.
Non-return Mode
In non-return mode, the ring link does not automatically recover. RPL node
does not reply after receiving the NR message, and the other nodes do not do
any action after receiving the NR message. Only when RPL node receives the
Clear command will the RPL node block the link and continuously send NR RB
messages to the two ring network ports, then Flush FDB.The rest of the ring
network nodes unblock all non RPL links after receiving the NR RB message, and
then Flush FDB.
Protection Switching —— Forced Switching
When a loop network node receives a forced switching command, it blocks the
data channel and R-APS channel (blocking the port of one data channel and
R-APS channel), opens the other loop network ports, and continuously sends FS
messages to the two loop network ports, then Flush FDB.. The remaining ring
network nodes receive FS messages and open the data flow and R-APS channels
through the RPL. The ring network node that sends FS message stops sending FS
message after receiving the message. Network nodes perform FDB Flush. after
receiving FS message
The above actions completed a forced switching operation, in order to
normal switching, there is a point to note:
When a forced switching command already exists in the ring network, subsequent
forced switching requests are accepted unless the node has previously accepted
a forced switching request. At the same time, the node receiving the new
switching command to re-enforce switching operation, blocking ports, sending
FS messages and so on. Of course, the execution of multiple forced switching
commands will split the ring network, so it should be properly avoided.
A node that performs a mandatory switching command clears the mandatory
switching command after receiving the Clear command. A node keeps blocking the
ring network port blocked by the previous forced switching command and
continuously sends NR messages to both ring network ports. and the following
link recovery, the behavior and function of return mode and non-return mode
are inconsistent.
Return Mode
In return mode, the ring link is restored. RPL node receives the NR message
and starts the WTB timer. WTB the timer timeout, the RPL node blocks the link,
sends NR RB messages, and Flush FDB. them The rest of the ring network nodes
unblock all non RPL links after receiving the NR RB message, and then Flush
FDB.
Non-return Mode
In non-return mode, the ring link does not automatically recover. RPL node
does not reply after receiving the NR message, and the other nodes do not do
any action after receiving the NR message. Only when RPL node receives the
Clear command will the RPL node block the link and continuously send NR RB
messages to the two ring network ports, then Flush FDB.The rest of the ring
network nodes unblock all non RPL links after receiving the NR RB message, and
then Flush FDB.
Replacement Recovery Process
The ring network protection node (RPL Owner) realizes the ring network
switching recovery through timer WTR (wait-to-restore timer) and timer WTB
(wait-to-block timer).WTR timer and WTB timer are used to avoid frequent
protection switching on the ring network. WTR timer only takes effect in
return mode, in non-return mode, when the ring network is recovered from the
protection state, the ring network recovery is not carried out, so there is no
need to turn on the WTR timer. while in return mode, after RPL node receives
NR messages from other nodes, the WTR timer is started. before the timer time-
out, the RPL node maintains the forwarding state of the port and does not send
a ring network recovery notification. When RPL node receives SF message again,
it indicates that the ring network has not been fully restored, and the node
stops WTR timer. WTR the RPL node re-blocking the port after the timer
timeout.
WTB timer only works in return mode, used when clearing forced and manual
switching commands. When you clear multiple forced switching commands, the WTB
timer ensures that a single forced switching command does not cause RPL to
duplicate blocking. When a manual switching command is cleared, the WTB timer
prevents the RPL node from receiving a closed loop caused by an outdated
remote MS request during recovery.
The WTB timer must ensure that there is enough time to receive remote FS、SF
and MS messages, so defining the WTB timer is 5 seconds longer than the Guard
timer, which is enough for a reporting ring node to send two R-APS messages
and allow the entire ring network to confirm situation.
ERPS Configuration
ERPS Configuration Notes
Before configuring the ERPS ring protection protocol, read the following
notes:
- ERPS port must be hosted on the CFM MEP port, to configure the information for the ERPS port to match the MEP port, the port can be enabled normally after success.
- The default VLAN (or control vlan) for all ring ports needs to be configured to ensure that ERPS messages are forwarded properly.
- The default VLAN and control VLAN of ERPS ring network ports can not be the same as EAPS control VLAN using both protocols. non-reforwardable protocol message in ERPS EAPS control VLAN.
- One port can not act as a ring network port for both ERPS and EAPS protocols.
- ERPS protocol supports configuring physical or aggregate ports as ring network ports. physical ports that have been configured for link aggregation ,802.1 X authentication, or port security are not configurable as ERPS ring network ports.
ERPS Configuration Tasks
- Configuration of ring network nodes
- Configure loop ports
- View Ring Protection Protocol Status
Configuration of Ring Network Nodes
In global configuration mode, follow the steps below to configure the switch
to ERPS nodes.
Description:
- Delete the ring network node configuration and the node port configuration using the no erps id command.
- interconnection-node 、 raps -virtual-channel 、,, reverie-mode these three commands are mandatory, they all have default configurations, so when you create a local node, you can omit these commands if you don’t need to modify their default values.
Configure Loop Ports
Follow the steps below to configure the switch port as a ring network port.
Description:
- Modify the RPL port to a normal ring network port by no erps id rpl port configuration command.
- Remove the normal ring network port (RPL neighbor port) or RPL port configuration via the no erps id ring-port port configuration command.
- The erps id ring-port (neighbour) and rpl commands will create a ring network node at the same time when the ring network node is not globally configured.
- Up mep can only be configured in interconnection-node nodes, and interconnection-node can only configure 1 ring network port.
Ring Network Control Command
In monitoring mode, use the following command to control the ring network
status.
View Ring Protection Protocol Status
Use the command below to view the ring protection protocol status.
ERPS Configuration Examples
Configuration Example 1- ERPS Single Ring Configuration
Figure 5.1 ERPS Single Ring Configuration
As shown in Figure 5.1, the S1、S2、S3、S4 configuration is as follows:
Configuration switch S1:
Configuration CFM functions:
- Switch#config
- Switch_config#ethernet cfm ENABLE
- Switch_config#ethernet cfm md mdnf STRING a level 4
- Switch_config_cfm#ma manf STRING a meps 1-2vlan 2
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING d level 4
- Switch_config_cfm#ma manf STRING d meps 1,4vlan 2
- Switch_config_cfm#exit
- Switch_config#interface f0/1
- Switch_config_f0/1#ethernet cfm ENABLE
- Switch_config_f0/1#ethernet cfm mep add mdnf STRING a manf STRING a mepid 1rmepid 2
- Switch_config_f0/1#interface f 0/4
- Switch_config_f0/4#ethernet cfm ENABLE
- Switch_config_f0/4#ethernet cfm mep add mdnf STRING d manf STRING d mepid 1rmepid 4
Network node configuration:
- Switch_config#erps 1
- Switch_config_ring1#control-vlan 2
- Switch_config_ring1#exit
- Switch_config#
Configure common ports:
- Switch_config#int erface f0/1
- Switch_config_f0/1#erps 1ring-port
- Switch_config_f0/1#erps 1cfm-disable
- Switch_config_f0/1#erps 1mep down md a ma a level 4local 1remote 2
Configure RPL ports:
- Switch_config#int erface f0/4
- Switch_config_f0/4#erps 1rpl
- Switch_config_f0/4#erps 1cfm-disable
- Switch_config_f0/4#erps 1mep down md d ma d level 4local 1remote 4
Configuration switch S2:
Configuration CFM functions:
- Switch#config
- Switch_config#ethernet cfm ENABLE
- Switch_config#ethernet cfm md mdnf STRING a level 4
- Switch_config_cfm#ma manf STRING a meps 1-2vlan 2
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING b level 4
- Switch_config_cfm#ma manf STRING b meps 2-3vlan 2
- Switch_config_cfm#exit
- Switch_config#interface f 0/1
- Switch_config_f0/1#ethernet cfm ENABLE
- Switch_config_f0/1#ethernet cfm mep add mdnf STRING a manf STRING a mepid 2rmepid 1
- Switch_config_f0/1#interface f 0/2
- Switch_config_f0/2#ethernet cfm ENABLE
- Switch_config_f0/2#ethernet cfm mep add mdnf STRING b manf STRING b mepid 2rmepid 3
Network node configuration:
- Switch_config#erps 1
- Switch_config_ring1#control-vlan 2
- Switch_config_ring1#exit
- Switch_config#
Configure common ports:
-
Switch_config#int erface f0/1
-
Switch_config_f0/1#erps 1ring-port
-
Switch_config_f0/1#erps 1cfm-disable
-
Switch_config_f0/1#erps 1mep down md a ma a level 4local 2remote 1
-
Switch_config_f0/1#int erface f0/2
Switch_config_f0/2#erps 1ring-port -
Switch_config_f0/2#erps 1cfm-disable
-
Switch_config_f0/2#erps 1mep down md b ma b level 4local 2remote 3
Configuration switch S3:
Configuration CFM functions:
-
Switch#config
-
Switch_config#ethernet cfm ENABLE
-
Switch_config#ethernet cfm md mdnf STRING b level 4
-
Switch_config_cfm#ma manf STRING b meps 2-3vlan 2
Switch_config_cfm#exit -
Switch_config#ethernet cfm md mdnf STRING c level 4
-
Switch_config_cfm#ma manf STRING c meps 3-4vlan 2
-
Switch_config_cfm#exit
-
Switch_config#interface f0/2
-
Switch_config_f0/2#ethernet cfm ENABLE
-
Switch_config_f0/2#ethernet cfm mep add mdnf STRING b manf STRING b mepid 3rmepid 2
Switch_config_f0/2#interface f0/3 -
Switch_config_f0/3#ethernet cfm ENABLE
-
Switch_config_f0/3#ethernet cfm mep add mdnf STRING c manf STRING c mepid 3rmepid 4
Network node configuration:
- Switch_config#erps 1
- Switch_config_ring1#control-vlan 2
- Switch_config_ring1#exit
- Switch_config#
Configure common ports:
-
Switch_config#int erface f0/2
-
Switch_config_f0/2#erps 1ring-port
-
Switch_config_f0/2#erps 1cfm-disable
-
Switch_config_f0/2#erps 1mep down md b ma b level 4local 3remote 2
-
Switch_config_f0/2#int erface f0/3
-
Switch_config_f0/3#erps 1ring-port
Switch_config_f0/3#erps 1cfm-disable -
Switch_config_f0/3#erps 1mep down md c ma c level 4local 3remote 4
Configuration switch S 4:
Configuration CFM functions:
-
Switch#config
-
Switch_config#ethernet cfm ENABLE
-
Switch_config#ethernet cfm md mdnf STRING c level 4
-
Switch_config_cfm#ma manf STRING c meps 3-4vlan 2
-
Switch_config_cfm#exit
-
Switch_config#ethernet cfm md mdnf STRING d level 4
-
Switch_config_cfm#ma manf STRING d meps 1,4vlan 2
-
Switch_config_cfm#exit
-
Switch_config#interface f0/3
-
Switch_config_f0/3#ethernet cfm ENABLE
-
Switch_config_f0/3#ethernet cfm mep add mdnf STRING c manf STRING c mepid 4rmepid 3
-
Switch_config_f0/3#interface f0/4
Switch_config_f0/4#ethernet cfm ENABLE -
Switch_config_f0/4#ethernet cfm mep add mdnf STRING d manf STRING d mepid 4rmepid 1
Network node configuration:
- Switch_config#erps 1
- Switch_config_ring1#control-vlan 2
- Switch_config_ring1#exit
- Switch_config#
Configure common ports:
- Switch_config#int erface f0/3
- Switch_config_f0/3#erps 1ring-port
- Switch_config_f0/3#erps 1cfm-disable
- Switch_config_f0/3#erps 1mep down md c ma c level 4local 4remote 3
Configure RPL neighbor ports:
- Switch_config#interface f0/4
- Switch_config_f0/4#erps 1neighbour
- Switch_config_f0/4#erps 1cfm-disable
- Switch_config_f0/4#erps 1mep down md d ma d level 4local 4remote 1
Configuration Example 2- ERPS Multi-ring Configuration
Figure 5.2 ERPS Multi-ring configuration
The interconnection node S 3 and S 4 configurations are as follows, as shown in Figure 5.2, and the other nodes are slightly configured.
Configuration switch S 3:
Configuration CFM functions:
- Switch#config
- Switch_config#ethernet cfm ENABLE
- Switch_config#ethernet cfm md mdnf STRING mdn b level 4
- Switch_config_cfm#ma manf STRING man b meps 2-3vlan 2
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING mdn c level 4
- Switch_config_cfm#ma manf STRING man c meps 3-4vlan 2
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING mdn g level 4
- Switch_config_cfm#ma manf STRING man g meps 3,6vlan 3
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING mdn u level 5
- Switch_config_cfm#ma manf STRING man u meps 3-4vlan 3
- Switch_config_cfm#exit
- Switch_config#interface f0/2
- Switch_config_f0/2#ethernet cfm ENABLE
- Switch_config_f0/2#ethernet cfm mep add mdnf STRING mdn b manf STRING man b mepid 3
- Switch_config_f0/2#ethernet cfm mep ENABLE mdnf STRING mdn b manf STRING man b mepid 3
- Switch_config_f0/2#ethernet cfm mep cci-ENABLE mdnf STRING mdn b manf STRING man b mepid 3
- Switch_config_f0/2#interface f0/3
- Switch_config_f0/3#ethernet cfm ENABLE
- Switch_config_f0/3#ethernet cfm mep add mdnf STRING mdn c manf STRING man c mepid 3
- Switch_config_f0/3#ethernet cfm mep ENABLE mdnf STRING mdn c manf STRING man c mepid 3
- Switch_config_f0/3#ethernet cfm mep cci-ENABLE mdnf STRING mdn c manf STRING man c mepid 3
- Switch_config_f0/3#interface f0/7
- Switch_config_f0/7#ethernet cfm ENABLE
- Switch_config_f0/7#ethernet cfm mep add mdnf STRING mdn g manf STRING man g mepid 3
- Switch_config_f0/7#ethernet cfm mep ENABLE mdnf STRING mdn g manf STRING man g mepid 3
- Switch_config_f0/7#ethernet cfm mep cci-ENABLE mdnf STRING mdn g manf STRING man g mepid 3
- Switch_config_f0/7#ethernet cfm mep add mdnf STRING mdn u manf STRING man u mepid 3direction up
- Switch_config_f0/7#ethernet cfm mep ENABLE mdnf STRING mdn u manf STRING man u mepid 3
- Switch_config_f0/7#ethernet cfm mep cci-ENABLE mdnf STRING mdn u manf STRING manu mepid 3
Network node configuration:
- Switch_config#erps 1
- Switch_config_ring1#control-vlan 2
- Switch_config_ring1#exit
- Switch_config#
- Switch_config#erps 2
- Switch_config_ring1#control-vlan 3
- Switch_config_ring1#interconnection-node
- Switch_config_ring1#exit
- Switch_config#
Configure ERPS1 common ports:
- Switch_config#int erface f0/2
- Switch_config_f0/2#erps 1ring-port
- Switch_config_f0/2#erps 1mep down md b ma b level 4local 3remote 2
- Switch_config_f0/2#int erface f0/3
- Switch_config_f0/3#erps 1ring-port
- Switch_config_f0/3#erps 1mep down md c ma c level 4local 3remote 4
Configure ERPS2 common ports:
- Switch_config_f0/3#int erface f0/7
- Switch_config_f0/7#erps 2ring-port
- Switch_config_f0/7#erps 2mep down md g ma g level 4local 3remote 6
- Switch_config_f0/7#erps 2mep down md u ma u level 5local 3remote 4
Configuration switch S 4:
Configuration CFM functions:
- Switch#config
- Switch_config#ethernet cfm ENABLE
- Switch_config#ethernet cfm md mdnf STRING mdn c level 4
- Switch_config_cfm#ma manf STRING man c meps 3-4vlan 2
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING mdn d level 4
- Switch_config_cfm#ma manf STRING man d meps 1,4vlan 2
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING mdn e level 4
- Switch_config_cfm#ma manf STRING man e meps 4-5vlan 3
- Switch_config_cfm#exit
- Switch_config#ethernet cfm md mdnf STRING mdn u level 5
- Switch_config_cfm#ma manf STRING man u meps 3-4vlan 3
- Switch_config_cfm#exit
- Switch_config#interface f0/3
- Switch_config_f0/3#ethernet cfm ENABLE
- Switch_config_f0/3#ethernet cfm mep add mdnf STRING mdn c manf STRING man c mepid 4
- Switch_config_f0/3#ethernet cfm mep ENABLE mdnf STRING mdn c manf STRING man c mepid 4
- Switch_config_f0/3#ethernet cfm mep cci-ENABLE mdnf STRING mdn c manf STRING man c mepid 4
- Switch_config_f0/3#interface f0/4
- Switch_config_f0/4#ethernet cfm ENABLE
- Switch_config_f0/4#ethernet cfm mep add mdnf STRING mdn d manf STRING man d mepid 4
- Switch_config_f0/4#ethernet cfm mep ENABLE mdnf STRING mdn d manf STRING man d mepid 4
- Switch_config_f0/4#ethernet cfm mep cci-ENABLE mdnf STRING mdn d manf STRING man d mepid 4
- Switch_config_f0/4#interface f0/5
- Switch_config_f0/5#ethernet cfm ENABLE
- Switch_config_f0/5#ethernet cfm mep add mdnf STRING mdn e manf STRING man e mepid 4
- Switch_config_f0/5#ethernet cfm mep ENABLE mdnf STRING mdn e manf STRING man e mepid 4
- Switch_config_f0/5#ethernet cfm mep cci-ENABLE mdnf STRING mdn e manf STRING man e mepid 4
- Switch_config_f0/5#ethernet cfm mep add mdnf STRING mdn u manf STRING man u mepid 4direction up
- Switch_config_f0/5#ethernet cfm mep ENABLE mdnf STRING mdn u manf STRING man u mepid 4
- Switch_config_f0/5#ethernet cfm mep cci-ENABLE mdnf STRING mdn u manf STRING man u mepid 4.
Network node configuration:
-
Switch_config#erps 1
-
Switch_config_ring1#control-vlan 2
-
Switch_config_ring1#exit
-
Switch_config#
-
Switch_config#erps 2
Switch_config_ring1#control-vlan 3 -
Switch_config_ring1#interconnection-node
-
Switch_config_ring1#exit
-
Switch_config#
Configure ERPS1 common ports:
- Switch_config#int erface f0/3
- Switch_config_f0/3#erps 1ring-port
- Switch_config_f0/3#erps 1mep down md c ma c level 4local 4remote 3
Configure ERPS1 RPL neighbor ports:
- Switch_config#int erface f0/4
- Switch_config_f0/4#erps 1neighbour
- Switch_config_f0/4#erps 1mep down md d ma d level 4local 4remote 1
Configure ERPS2 common ports:
- Switch_config#int erface f0/5
- Switch_config_f0/5#erps 2ring-port
- Switch_config_f0/5#erps 2mep down md e ma e level 4local 4remote 5
- Switch_config_f0/5#erps 2mep down md u ma u level 5local 4remote 3
erps: showing switch S3
- Switch_config#show erps
- Ethernet Ring Protection Switching
Ring1
RPL Owner Priority Unknown
Address
This node is the RPL Owner
- Node ID Priority 32770(priority 32770 id 1)
- Address 00E0.0F81.111B
- Control Vlan 2
- Version 1
- RAPS Virtual Channel: True
- Revertive Mode: Revertive
- State Pending WTR False
- Signal Fail False Sending NR
- WTR time 0/20sec WTB time 0/6sec
- Guard time 0/500ms Send time 1/5sec
Interface Role State Status MEP Role
- F0/2Ring-Port BLK Link-down DOWN-MEP
- F0/3Ring-Port FWD Link-down DOWN-MEP
Ring2
RPL Owner Priority Unknown
Address
Node ID Priority 32770(priority 32768 id 2)
- Address 00E0.0F81.111B
- Control Vlan 3
Version 1
This node is the interconnection node
- RAPS Virtual Channel: True
- Revertive Mode: Revertive
- State Protection
- Signal Fail False Sending SF
- WTR time 0/20sec WTB time 0/6sec
- Guard time 0/500ms Send time 1/5sec
Interface Role State Status MEP Role
F0/7Ring-Port FWD Link-up DOWN-MEP
F0/7(up) Ring-Port BLK Link-down UP-ME
Website: www.fs.com