Midea VSA7 Series Split Type Wall Mounted Air Conditioner Owner’s Manual
- October 30, 2023
- Midea
Table of Contents
VSA7 Series Split Type Wall Mounted Air Conditioner
Product Information: Split Type Wall Mounted
Air-Conditioner
The Split Type Wall Mounted Air-Conditioner comes in various
models: VSA7-09BE, VSA7-12BE, VSA7-18BE, VSA7-24BE, VSA2-12BE,
VSA4-12BE, and VSA9-12BE. The product comes with an owner’s manual
that contains instructions for operation and maintenance, safety
precautions, notices for use, names of each part, clean and care,
troubleshooting, installation service, notices for installation,
install indoor unit, install outdoor unit, and check after
installation and test operation. The product is designed to be used
by persons aged 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the
hazards involved.
Product Usage Instructions: Safety Precautions
Before operating the Split Type Wall Mounted Air-Conditioner, it
is important to read the owner’s manual carefully and thoroughly.
The manual contains safety precautions that must be followed to
prevent harm or damage to people and properties.
-
Ensure that the air conditioner is grounded to prevent electric
shocks. -
Before plugging in the unit, ensure that there is no dust on it
and that it is plugged fully in place. -
Do not connect the earth wire to the gas pipeline, water
pipeline, lightning rod, or telephone earth wire. -
If the power supply is damaged, it must be replaced by its
service agent or a similar qualified person. -
Take care not to let the remote control and the indoor unit get
watered or being too wet. -
Always switch off the device and cut the power supply before
performing any maintenance or cleaning. -
Do not pull the power cord when pulling out the power
plug. -
Do not share the socket with other electric appliances.
Failure to follow these safety precautions may result in serious
injuries or damage to properties.
Owner,s Manual
Split type wall mounted air-conditioner
Model NO
VSA7-09BE VSA7-12BE VSA7-18BE VSA7-24BE VSA2-12BE VSA4-12BE VSA9-12BE
Please read this owner,s manual carefully and thoroughly before operating the
unit!
Take care of this manual for future reference.
CONTENTS
Operation and maintenance
Safety Precautions
1
Notices for use
6
Names of each part
8
Clean and care
9
Troubleshooting
10
Installation service
Notices for installation
12
Install indoor unit
15
Install outdoor unit
18
Check after installation and test operation
21
Note: All the pictures in this manual are just schematic diagrams, the actual is the standard.
Safety Precautions
Incorrect installation or operation by not following these instructions may cause harm or damage to people, properties, etc. The seriousness is classified by the following indications
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to properties.
WARNING
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision. (Only for the AC with CE-
MARKING)
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance. (Except for
the AC with CE-MARKING)
– 1 –
Safety precautions
The air conditioner must be grounded. Incomplete grounding may result in electric shocks.
Pull out the plug Before the connector (or cut off the main is plugged in, please power switch) when make sure that there the unit is not in use is no dust on it and for long time so as that it is plugged fully to ensure safety. in place.
OFF
Do not connect the earth wire to the gas pipeline, water pipeline, lightning
rod, or telephone earth wire.
If the power supply Don’t pull out the cord is damaged, it power plug during
must be replaced by operating or with the manufacture or wet hands. its
service agent or a similar qualified person.
NO!
It may cause electric shock or fire.
Take care not let the remote control and the indoor unit watered or being too wet.
SET TEMPERATURE()
AUTO COOL DRY HEAT
FAN HIGH MID LOW
ON/OFF SET
MODE CLEAN SPEED
SLEEP HEALTH STRONG
SWING
FEELING
DUST FUNGUSPROOF SCREEN TIMER
NO!
Otherwise, it may cause short circuit even fire.
Always switch off the device and cut the power supply before performing any maintenance or cleaning.
Don’t pull the power cord when pull out the power plug.
Don’t share the socket with other electric appliance.
OFF
Otherwise, it may cause electric shock or damage.
NO!
NO!
The damage of pulling power cord will cause serious electric shock.
– 2 –
Otherwise, it may cause electric shock even fire.
Safety Precautions
Don’t install air conditioner in a place where there is flammable gas or
liquid. The distance between them should above 1m.
above 1m
It may cause fire.
Don’t use air conditioner in lightning strom weather.
Don’t use liquid or corrosive cleaning agent wipe the air conditioner and sprinkle water or other liquid either.
Don’t attempt to repair the air conditioner by yourself.
NO!
NO!
Doing this may case electric shock or damage to the unit.
Incorrect repairs may cause electric or fire. Contact a qualified service technician for all service requirement.
Don’t put hands or Please note whether any objects into the the installed stand is air inlets or outlets. firm enough or not.
Lightning
NO!
OFF
Power supply should be cut in time to prevent the occurrence of danger.
Don’t block air inlet or air outlet.
NO!
Otherwise, the cooling or heating capacity will be weakened, even cause system
stop operating.
This may cause personal injury or damage to the unit.
Don’t let the air conditioner blow against the heater appliance.
Otherwise it will lead to incomplete combustion, thus causing poisoning.
– 3 –
If it is damaged, it may lead to the fall of the unit and cause the injury.
An earth leakage breaker with rated capacity must be installed to avoid
possible electric shocks.
The appliance shall be installed in accordance with national wiring
regulations.
Safety Precautions
This product contains fluorinated greenhouse gases.
WEEE Warning Meaning of crossed out wheeled dustbin: Do not dispose of
electrical appliances as unsorted municipal waste, use separate collection
facilities. Contact you local government for information regarding the
collection systems available. If electrical appliances are disposed of in
landfills or dumps, hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being. When replacing old
appliances with new ones, the retailer is legally obligated to take back your
old appliance for disposals at least free of charge.
– 4 –
Safety Precautions
CAUTION
Don’t open the
Don’t stand on the
windows and doors top of the outdoor
for long time when unit or place heavy
the air conditioner things on it.
is running.
Don’t use the air conditioner for other purposes, such as drying clothes, preserving foods,etc.
NO! NO!
Otherwise, the cooling or heating This cloud cause personal
capacity will be weakened.
injuries or damage the unit.
Don’t apply the cold air to the body for a long time.
NO!
It will deteriorate your physical conditions and cause health problems.
Set the suitable If your air
temperature.
conditioner is not
fitted with a supply
It is recommended that the temperature difference between indoor and outdoor temperature should not be too large.
cord and a plug, an all-pole switch must be installed in the fixed wiring and the distance between
contacts should be
Appropriate adjustments of the no less than 3.0 mm.
setting temperature can prevent
the waste of electricity.
If your air conditioner is permanently connected to the fixed wiring, a residual current device (RCD) having rated residual operating current not exceeding 30 mA should be installed in the fixed wiring.
The power supply circuit should have leakage protector and air switch of which the capacity should be more than1.5 times of the maximum current.
– 5 –
Notices for use
The conditions of unit can’t normally run
- Within the temperature range provided in following table, the air conditioner may stop running and other anomalies may arise.
Cooling Heating
Outdoor Indoor Outdoor Indoor
43(Apply to T1) 52(Apply to T3) 18 24 -7
27
- When the temperature is too high, the air conditioner may activate the automatic
protection device, so that the air conditioner could be shut down. When the temperature is too low, the heat exchanger of the air conditioner may
freeze, leading to water leakage or other malfunction. In long-term cooling or dehumidification with a relative humidity of above 80%
(doors and windows are open), there may be water condenses or dripping near
the air outlet. * T1 and T3 refer to ISO 5151.
Notes for heating
- The fan of the indoor unit will not start running immediately after the heating is started to avoid blowing out cool air.
- When it is cold and wet outside, the outdoor unit will develop frost over the heat exchanger which will compromise the heating capacity. This is when the air conditioner will start defrost.
- During defrost, the air conditioner will stop heating for about 5-12 minutes. Vapor may come out from the outdoor unit during defrost. This is not a malfunction,
but a result of fast defrost. Heating will resume after defrost is complete.
Notes for turning off - When the air conditioner is turned off, the main controller will automatically decide whether to stop immediately or after running for dozens of seconds with lower frequency and lower air speed.
– 6 –
Notices for use
Emergency operation
- If the remote controller is lost or broken, use force switch button to operate the air conditioner.
- If this button is pushed with the unit OFF, the air conditioner will operate in Auto mode.
- If this button is pushed with the unit ON, the air conditioner will stop running.
Force switch
Airflow direction adjustment
1. Use up-down swing and left-right swing buttons on the remote controller to
adjust the airflow direction. Refer to the operation manual of the remote
controller for detail.
2. For models without left-right swing function, the fins has to be moved
manually.
Note: Move the fins before the unit is in operation, or your finger might be
injured. Never place your hand into the air inlet or outlet when the air
conditioner is in operation.
ATTENTION
If the equipment emissions cannot meet the technical requirement of IEC
61000-3-3, following Attention should be take care. Attention:This appliance
can be connected only to a supply with system impedance no more than Zmax. In
case necessary, please consult your supply authority for system impedance
information.
Product Type
ASTW-H12L4/#-IQ
Zmax
0.445
Product Type
ASTW-(H)18QA2/#R1-SA
Zmax
0.331
ASTW-12U4/#-AE
0.445
ASTW-20U4/L#-IR
0.07
ASW-H15D3A4/#R1-C5
0.392
ASTW-24G4/#-AE
0.027
ASTW-H18U4/#-IQ
0.128
ASTW-H24C4/#-IQ
0.027
ASTW-18U4/#-AE
0.128
ASW-H24F6A4/#R1-C5
0.281
ASW-H18E1A4/#R1-C5
0.422
ASTW-30P4/#-AE
0.026
=LK700,LF,LH,LI,LM,LN,LR,LU,LS,LD,LP,
LQ,LB,LO,LC,LE,LL,ULK700,ULF,ULH,ULM,ULN,ULI,ULS,ULU,ULD,ULP,ULR, ULQ,ULB,ULO,ULC,ULE,ULL,QLK700,QLF,QLH,QLM,QLN,QLI,QLS,QLU,QLD,QLP,QLR,QLQ,QLB,QLO,QLC,QLE, QLLGLK700,GLF,GLH,GLM,GLN,GLI,GLS,GLU,GLD,GLP,GLR,G LQ,GLB,GLO,GLC,GLE,GLL
ASW-H18E1A4/#R1-RU
0.421
ASW-H24B4/#R1-RU
0.315
ASTW-18Q4/#-AE
0.112
= FA,FB,FD,FI,FJ,FO,FC,FY,FQ,FM,FF,FH,FVMA
– 7 –
Names of each part
Indoor unit
Air inlet grille Panel
Air inlet Force switch
Air filter
Air louver Air vent
Air outlet
iFEEL
Power cord Pipe protection ring
Remoter controller
Outdoor unit
Air inlet
Air outlet grille
Connecting pipe Drain hose
Air outlet
Note: All the pictures in this manual are just schematic diagrams, the actual
is the standard.
– 8 –
Clean and care
Warning
Before the cleaning of the air conditioner, it must be shut down and the
electricity must be cut off for more than 5 minutes, otherwise there might be
the risk of electric shocks.
Do not wet the air conditioner, which can cause an electric shock. Make sure
not to rinse the air conditioner with water under any circumstances.
Volatile liquids such as thinner or gasoline will damage the air conditioner
housing, therefore please clean the housing of air conditioner only with soft
dry cloth and damp cloth moistened with neutral detergent.
In the course of the using, pay attention to cleaning the filter regularly, to
prevent the covering of dust which may affect the effect. If the service
environment of the air conditioner is dusty, correspondingly increase the
number of times of cleaning. After removing the filter, do not touch the fin
part of the indoor unit with the finger, so as to avoid scratching it.
Clean the panel
When the panel of the indoor unit is contaminated, clean it gently with a
wrung towel using tepid water below 45, and do not remove the panel while
cleaning.
Remove the air filter
Clean the air filter
1. Use both hands to open the panel for an angle from both ends of the panel
in accordance with the direction of the arrow.
2. Release the air filter from the slot and remove it.
Clean the Air Filter Use a vacuum cleaner or water to rinse filter, and if the
filter is very dirty (for example, with greasy dirt), clean it with warm water
(below 45) with mild detergent dissolved in, and then put the filter in the
shade to dry in the air.
– 9 –
Clean and care
Clean the air filter
Mount the Filter 1. Reinstall the dried filter in reverse order of removal,
then cover and lock the panel.
Check before use
1. Check whether all the air inlets and outlets of the units are unblocked.
2. Check whether there is blocking in the water outlet of the drain pipe, and
immediately clean it up if any. 3. Check the ground wire is reliably grounded.
4. Check whether the remote control batteries are installed, and whether the
power
is sufficient. 5. Check whether there is damage in the mounting bracket of the
outdoor unit, and
if any, please contact our local service center.
Maintain after use
1. Cut off the power source of the air conditioner, turn off the circuit
breaker and remove the batteries from the remote control.
2. Clean the filter and the unit body. 3. Remove the dust and debris from the
outdoor unit. 4. Check whether there is damage in the mounting bracket of the
outdoor unit, and if
any, please contact our local service center.
Troubleshooting
Caution
- Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or fire, please contact the authorized service center and let the professionals conduct the maintenance, and checking the following items prior to contacting for maintenance can save your time and money.
– 10 –
Troubleshooting
Phenomenon
Troubleshooting
Air conditioner can not operate at all.
Remote controller is not available.
Cooling (Heating) efficiency is not good.
Has the power been shut down?
Is the wiring loose?
Is voltage too high or too low ?(measured by professionals)
Does it reach the set time for start up?
Does the circuit protection device trip?
Is the remote controller out of effective distance to the indoor unit?
Are there any obstructions between the controller and the
signal receptor?
Is the battery exhausted?
Is the setting temperature suitable? Are air filter dirty? Is the air inlet or outlet obstructed? Is indoor fan speed set at low speed? Is there any heat source in your room?
Indoor unit does not operate immediately when the air conditioner is restarted.
If the air conditioner is turned on immediately after it is turned off, the protective delay switch will delay the operation for 3 to 5 minutes.
There is unusual smell blowing from the outlet after operation is started.
The air conditioner itself does not have undesirable odor. If there is odor, it may be due to accumulation of the odor in the environment. Please clean the air filter or activate the cleaning function.
There is sound of running water during the running of air conditioner.
Sometimes the “hissing” sound of running water can be heard. This is the sound of the flow of the refrigerant, not a malfunction.
A slight “click” sound is heard at the of start-up or shut-down.
Due to temperature changes, panel and other parts will swell, causing the sound of friction. This is normal, not a fault.
During the cooling operation, the indoor unit outlet sometimes will blow out mist.
This is because the indoor air is cooled rapidly. After it runs for some time, the indoor temperature and humidity will be reduced and the mist will disappear.
Immediately stop all operations and cut off the power supply , contact our
Service center locally in following situations.
Shrill sound is heard or Unpleasant odor is emitted during the operation.
There is an abnormal heat in power supply cord and power plug. Accidentally
pour impurities or water into the machine or the remote control. Air switch or
protection switch often breaks.
– 11 –
Notices for installation
Important Notices
Before installating, please contact with local authorized maintenance center,
if unit is not installed by the authorized maintenance center, the malfunction
may not solved,due to discommodious contact.
The air conditioner must be installed by professionals according to the
national wiring rules and this manual.
To move and install air conditioner to another place, please contact our local
special service center.
Requirements For Installation Position
Avoid places of inflammable or explosive gas leakage or where there are
strongly aggressive gases.
Avoid places subject to strong artificial electric/magnetic fields. Avoid
places subject to noise and resonance. Avoid severe natural conditions (e.g.
heavy lampblack, strong
sandy wind, direct sunshine or high temperature heat sources). Avoid places
within the reach of children. Shorten the connection between the indoor and
outdoor units. Select where it is easy to perform service and repair and
where the ventilation good. The outdoor unit shall not be installed in any way
that could
occupy an aisle, stairway, exit, fire escape, catwalk or any other public
area. The outdoor unit shall be installed as far as possible from the doors
and windows of the neighbors as well as the green plants.
Requirements for operations at raised height
When carrying out installation at 2m or higher above the base level, safety
belts must be worn and ropes of sufficient strength be securely fasten to the
outdoor unit, to prevent falling that could cause personal injury or death as
well as property loss.
– 12 –
Notices for installation
Requirements of the mounting structure
The mounting rack must meet the relevant national or industrial standards in
terms of strength with welding and connection areas rustproofed.
The mounting rack and its load carry surface shall be able to withstand 4
times or above the weight of the unit, or 200kg, whichever is heavier.
The mounting rack of the outdoor unit shall be fastened with expansion bolt.
Ensure the secure installation regardless of what type of wall on which it is
installed, to prevent potential dropping that could hurt people.
Electrical Safety Requirements
Be sure to use the rated voltage and air conditioners dedicated circuit for
the power supply, and the power cord diameter must meet the national
requirements.
When the maximum current of air conditioner is 16A, it must use the air switch
or leakage protection switch equipped with protection devices.
The normal operating range is 90%-110% of the local rated voltage. The minimum
clearance between the air conditioner and the
combustibles is 1.5 m.
Grounding Requirements
The air conditioner is the type I electrical appliance and must ensure a
reliable grounding.
Do not connect the grounding wire to a gas pipe, water pipe, lightning rod,
telephone line, or a circuit poorly grounded to the earth.
The grounding wire is specially designed and shall not be used for other
purpose, nor shall it be fastened with a common tapping screw.
– 13 –
Notices for installation
Others
The connection method of the air conditioner and the power cord and the
interconnection method of each independent element shall be subject to the
wiring diagram affixed to the machine.
The model and rating value of the fuse shall be subject to the silkscreen on
corresponding controller or fuse sleeve.
Packing list
Packing list of the indoor unit
N0.
Name
1
Indoor Unit
2
Remote Controller
3
Batteries(7#)
4
Instructions
5
Drain pipe
Quantity Unit
1
Set
1
PC
2
PC
1
Set
1
PC
Packing list of the outdoor unit
N0.
Name
1
Outdoor Unit
2
Connecting pipe
3
Plastic Strap
4
Pipe Protection Ring
5
Luting (putty)
Quantity Unit
1
Set
2
PC
1
ROLL
1
PC
1 PACKET
NOTE: All accessories shall be subject to actual packaging material, and if
there is any difference, please understand.
– 14 –
Install indoor unit
Dimension drawing of indoor unit installation
Space to the wall 20cm above
Space to the ceiling 15cm above
Space to the wall 20cm above
200cm above Space to the floor
Mounting plate
1. The wall for installation of the indoor unit shall be hard and firm, so as
to prevent vibration.
2. Use the “+” type screw to fasten the peg board, horizontally mount the peg
board on the wall, and ensure the lateral horizontal and longitudinal
vertical.
3. Pull the peg board by hand after the installation, to confirm whether it
is solid.
Wall-through Hole
1. Make a hole with an electric hammer or a water drill at the predetermined
position on the wall for piping, which shall slant outwardly by 5°-10°.
2. To protect the piping and the cables from being damaged running through
the wall, and from the rodents that may inhabit in the hollow wall, a pipe
protecting ring shall be installed and sealed with putty.
Note: Usually, the wall hole is 60mm~80mm. Avoid pre-buried power wire and
hard wall when making the hole.
Putty
– 15 –
Pipe protection ring
Install indoor unit
Route of Pipeline
1. Depending on the position of the unit, the piping may be routed sideway
from the left or the right ( Fig 1 ), or vertically from the back( Fig 2
)(depending on the pipe length of the indoor unit). In the case of sideway
routing, cut off the outlet cutting stock of the opposite side.
2. The power cord may be routed separately from the piping. Cut off the
outlet cutting stock and then run the power cord through the hole, keeping the
remaining part as a protection from rodents.
Power cord
Connecting Pipe Drain Hose and Cables
Connecting Pipe Drain Hose and Cables
Hole material preparation
Fig 1
Outlet material preparation
Fig 2
Drain pipe connection
1. Remove the mountings and pull the indoor unit pipe out of the housing. 2.
Connect the connecting pipe to the indoor unit:
Aim at the pipe center, tighten the Taper nut with fingers, and then tighten
the Taper nut with a torque wrench, and the direction is shown in diagram on
the right. The torque used is shown in the following table.
Tightening torque table
The size of pipe(mm) 6/6.35 9 . 5 2 12/12.7 1 5 . 8 8 1 9 . 0 5
Torque(N·m) 7 58 0
Indoor unit pipe
Taper nut connecting pipe
Spanner
Torque wrench
Wrap the Piping
1. Use the insulation sleeve to wrap the joint part the indoor unit and the
connection pipe, and then use insulating material to pack and seal insulation
pipe, to prevent generation of condensate water on the joint part.
2. Connect the water outlet with drain pipes, and make the connection pipe,
cables, and the drain hose straight.
3. Use plastic cable ties to wrap the connecting pipes, cables and drain
hose. Run the pipe sloping downward.
– 16 –
Connecting Pipe Drain Hose and Cables
Plastic Strap
Install Indoor Unit
Fixing the Indoor Unit
1. Hang the indoor unit on the peg board, and move the unit from left to
right to ensure that the hook is properly positioned in the peg board.
2. Push toward the lower left side and the upper right side of the unit
toward the peg board, until the hook is embedded in the slot and makes a
“click” sound.
Wiring diagram
If your air conditioner is provided with power cable, the wiring of the indoor
unit is connected in the factory, there is no need of connection.
If the power cable is not provided, connection is needed in accordance with
the wiring diagram.
constant speed
Cooling Only
Heat-pump type
Variable speed
LN
S
1 2(N)
1 2(N)
45
To Outdoor unit
To Outdoor unit
54 3
2(N) 1(L)
To Outdoor unit
To Outdoor unit
54 3
2(N) 1(L)
To Outdoor unit
Connector
If there is a connector, connect it directly.
NOTE: This manual is usually includes the wiring mode for the different kind
of A/C.
We cannot exclude the possibility that some special type of wiring diagrams
are not included. The diagram are for reference only. If the entity is
difference with this wiring diagram, please refer to the detailed wiring
diagram adhered on the unit which you purchased.
– 17 –
Install outdoor unit
Dimension drawing of outdoor unit installation
20cm Above
Space to the obstruction
10cm Above Air in side
30cm Above
Space to the obstruction
Air out side
200cm Above
H
W1 W2
Left installation feet
Right installation feet
Air inlet A
B
D
Air outlet
30cm Above Space to the obstruction
Installation outdoor unit bolt
Outdoor Unit Size of Shape W1(W2)HD) (mm) 665(710)×420×280 600(645)×485×260
660(710)×500×240 700(745)×500×255 730(780)×545×285 760(810)×545×285
790(840)×550×290 800(860)×545×315 800(850)×590(690)×310 825(880)×655×310
900(950)×700×350 900(950)×795×330
A (mm)
430 400 500 460 540 540 545 545 540 540 630 535
B (mm)
280 290 260 260 280 280 300 315 325 335 350 350
Install the connection pipe
Connect the Outdoor Unit with Connecting Pipe: Aim the counter-bore of the connecting pipe at the stop valve, and tighten the Taper nut with fingers. Then tighten the Taper nut with a torque wrench.
Stop valve Taper nut Connecting pipe
When prolonging the piping, extra amount of refrigerant must be added so that the operation and performance of the air conditioner will not be compromised.
Piping length Amount of refrigerant to be added
5M 5-15M
Not needed
CC12000Btu
20g/m
CC18000Btu
30g/m
Note: This table is for reference only.
liquid side pipe Gas side pipe
Spanner
– 18 –
Install outdoor unit
Wiring Connection
1.Loosen the screws and remove E-parts cover from the unit.
2.Connect the cables respectively to the corresponding terminals
E-parts cover
1 2 NL
of the terminal board of the outdoor unit (see the wiring diagram),
and if there are signals connected to the plug, just conduct butt joint.
3.Ground wire: Remove the grounding screw out of the electric
bracket, cover the grounding wire end onto the grounding screw
and screw it into the grounding hole.
4.Fix the cable reliably with fasteners (Pressing board).
5.Put the E-parts cover back in its original place and fasten
it with screws.
Wiring diagram
constant speed
Cooling Only
Heat-pump type
1 2(N)
1 2(N) 4 5
To Indoor unit 1 23
To Indoor unit
1 2345
To Indoor unit
To Indoor unit
Variable speed 1(L) 2(N) 4(S)
To Indoor unit Connector
If there is a connector, connect it directly.
NOTE: This manual is usually includes the wiring mode for the different kind
of A/C.
We cannot exclude the possibility that some special type of wiring diagrams
are not included. The diagram are for reference only. If the entity is
difference with this wiring diagram, please refer to the detailed wiring
diagram adhered on the unit which you purchased.
– 19 –
Install outdoor unit
Expelling the air
Outdoor unit refrigerant discharging method After the pipe side connection is
complete, proceed as follows.
Gas part Liquid part
Loosen the
Wait for Quickly tighten and 8 second connect the nut.
temporarily fastened nut by half turn.
The installing torque is the same as that
of the gas end of
the indoor unit.
Loosen the Hex wrench by half turn.
Fully open the spindles of the liquid end and of the other two ends.
Check that all indoor and outdoor connections are free of air leakage.
Vacuum Pumping Method (R410A refrigerant evacuation must use the vacuum
pumping method)
Before working on the air conditioner, remove the cover of the stop valve(gas and
liquid valves)and be sure to retighten it afterward.(to prevent the potential air leakage)
1. To prevent air leakage and spilling tighten all connecting nut of all
flare tubes.
2. Connect the stop valve, charge hose, manifold valve, and vacuum pump.
3. Fully open the handle Lo of the manifold valve
Compound meter -76cmHg
Handle Lo Charge hose
Pressure gauge manifold valve Handle Hi
and apply vacuum for at least 15 minutes and
Charge hose
check that the compound vacuum gauge reads
-0.1MPa(-76cmHg).
4. After applying vacuum, fully open the stop
valve with a hex wrench.
Vacuum pump
5. Check that both indoor and outdoor
connections are free of air leakage.
Stop valve Stop valve (liquid valve) (gas valve)
Outdoor condensation drainage(Heat pump type only)
When the unit is heating, the condensing water and defrosting water can be out reliably through the drain house. Installation Install the outdoor drain elbow in 25 hole on the base plate, and joint the drain hose to the elbow, so that the waste water formed in the outdoor unit can be drained out to a proper plate.
Chassis Outdoor drain elbow
– 20 –
Check after installation and test operation
Check after installation
Electrical Safety Check 1. If the supply voltage is as required. 2. If there
is any faulty or miss connection in each of the power, signal and
grounding wires. 3. If the grounding wire of the air conditioner is securely
grounded. Installation Safety Check 1. If the installation is secure. 2. If
the water drain is smooth. 3. If the wiring and piping are correctly
installed. 4. Check that no foreign matter or tools are left inside the unit.
Leak test of the refrigerant Depending on the installation method, the
following methods may be used to check for suspect leak, on areas such as the
four connections of the outdoor unit and the cores of the cut-off valves and
t-valves: 1.Bubble method: Apply of spray a uniform layer of soap water over
the suspected
leak spot and observe carefully for bubble. 2.Instrument method: Checking for
leak by pointing the probe of the leak detector
according to the instruction to the suspect points of leak.
Test Operation
Test Operation preparation Verify that all piping and connection cables are
well connected. Confirm that the values at the gas side the liquid-side are
fully open. Connect the power cord to an independent power socket. Install
batteries in remote control. Test Operation method 1. Turn on the power and
push the ON/OFF switch button of the remote controller to
start the air conditioner. 2. Select COOL, HEAT (not available on cool-only
models), SWING and other
operation modes with the remote controller and see if the operation is ok.
– 21 –
Modeli
VSA7-09BE VSA7-12BE VSA7-18BE VSA7-24BE VSA2-12BE VSA4-12BE VSA9-12BE
Read User Manual Online (PDF format)