NATIONAL INSTRUMENTS NI-9775 4 Channel C Series Digitizer Module User Guide
- October 30, 2023
- NATIONAL INSTRUMENTS
Table of Contents
- NATIONAL INSTRUMENTS NI-9775 4 Channel C Series Digitizer Module
- Product Information: NI-9775
- Product Usage Instructions
- GETTING STARTED GUIDE
- Safety Guidelines
- Safety Voltages
- Electromagnetic Compatibility Guidelines
- Preparing the Environment
- NI 9775 Pinout
- Single-Ended Connections
- NI 9775 Connection Guidelines
- Where to Go Next
- Worldwide Support and Services
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NATIONAL INSTRUMENTS NI-9775 4 Channel C Series Digitizer Module
Product Information: NI-9775
The NI-9775 is a device that allows for connection to a chassis. It is important to complete the software and hardware installation procedures in your chassis documentation before use. Safety guidelines must be followed to prevent product misuse that can result in hazard. The NI-9775 is only to be operated as described in the user manual, and if damaged, it should be returned to NI for repair. The device is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous locations; and nonhazardous locations only.
Safety Guidelines
- Operate the NI-9775 only as described in the user manual.
- Do not operate the NI-9775 in a manner not specified in the user manual.
- Connect only voltages that are within Measurement Category O.
- Do not connect the NI-9775 to signals or use for measurements within Measurement Categories II, III, or IV.
- Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous.
- Do not remove modules unless power has been switched off or the area is known to be nonhazardous.
- For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15.
- You must make sure that transient disturbances do not exceed 140% of the rated voltage.
- The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1.
- The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.
- The enclosure must have a door or cover accessible only by the use of a tool.
Electromagnetic Compatibility Guidelines:
The NI-9775 was tested and complies with the regulatory requirements and limits for electromagnetic compatibility (EMC) stated in the product specifications. To minimize interference with radio and television reception and prevent unacceptable performance degradation, install and use this product in strict accordance with the instructions in the product documentation.
Product Usage Instructions
- Complete the software and hardware installation procedures in your chassis documentation before use.
- Refer to the user manual for safety guidelines specific to the NI-9775.
- Connect only voltages that are within Measurement Category O.
- Do not connect the NI-9775 to signals or use for measurements within Measurement Categories II, III, or IV.
- Follow the safety guidelines for hazardous locations if installing the NI-9775 in a potentially explosive environment.
- Install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15 for Division 2 and Zone 2 applications.
- Make sure that transient disturbances do not exceed 140% of the rated voltage.
- The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1.
- The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.
- The enclosure must have a door or cover accessible only by the use of a tool.
- Refer to the user manual for further usage instructions.
Bridging the gap between the manufacturer and your legacy test system.
COMPREHENSIVE SERVICES
We offer competitive repair and calibration services, as well as easily
accessible documentation and free downloadable resources.
RESET SELL YOUR SURPLUS
We buy new, used, decommissioned, and surplus parts from every NI series. We
work out the best solution to suit your individual needs.
- Sell For Cash
- Get Credit
- Receive a Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
1-800-915-6216
www.apexwaves.com
sales@apexwaves.com
All trademarks, brands, and brand names are the property of their respective owners.
Request a Quote CLICK HERE USB-6216
GETTING STARTED GUIDE
NI 9775
4-Ch, ±10 V, 20 MS/s, 14-Bit Digitizer
This document explains how to connect to the NI 9775.
- Note Before you begin, complete the software and hardware installation procedures in your chassis documentation.
- Note The guidelines in this document are specific to the NI 9775. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system.
Safety Guidelines
Operate the NI 9775 only as described in this document.
- Caution Do not operate the NI 9775 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair.
Safety Voltages
Connect only voltages that are within Measurement Category O.
Isolation
- Channel-to-channel None
- Channel-to-earth ground None
Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.
Caution Do not connect the NI 9775 to signals or use for measurements within Measurement Categories II, III, or IV.
Safety Guidelines for Hazardous Locations
The NI 9775 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4
hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous
locations; and nonhazardous locations only. Follow these guidelines if you are
installing the NI 9775 in a potentially explosive environment. Not following
these guidelines may result in serious injury or death.
- Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous.
- Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous.
- Caution Substitution of components may impair suitability for Class I, Division 2.
- Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15.
Special Conditions for Hazardous Locations Use in Europe and
Internationally
The NI 9775 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12
ATEX 1202658X and is IECEx UL 14.0089X certified. Each NI 9775 is marked II 3G
and is suitable for use in Zone 2 hazardous locations, in ambient temperatures
of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9775 in Gas Group IIC
hazardous locations, you must use the device in an NI chassis that has been
evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC T4 equipment.
- Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage.
- Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC/EN 60664-1.
- Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.
- Caution The enclosure must have a door or cover accessible only by the use of a tool.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and
limits for electromagnetic compatibility (EMC) stated in the product
specifications. These requirements and limits provide reasonable protection
against harmful interference when the product is operated in the intended
operational electromagnetic environment.
This product is intended for use in industrial locations. However, harmful
interference may occur in some installations, when the product is connected to
a peripheral device or test object, or if the product is used in residential
or commercial areas. To minimize interference with radio and television
reception and prevent unacceptable performance degradation, install and use
this product in strict accordance with the instructions in the product
documentation.
Furthermore, any changes or modifications to the product not expressly
approved by National Instruments could void your authority to operate it under
your local regulatory rules.
Caution To ensure the specified EMC performance, operate this product
only with shielded cables and accessories. Do not use unshielded cables or
accessories unless they are installed in a shielded enclosure with properly
designed and shielded input/output ports and connected to the product using a
shielded cable. If unshielded cables or accessories are not properly installed
and shielded, the EMC specifications for the product are no longer guaranteed.
Caution To ensure the specified EMC performance, the length of all I/O cables
must be no longer than 30 m (100 ft).
Special Conditions for Marine Applications
Some products are Lloyd’s Register (LR) Type Approved for marine (shipboard)
applications. To verify Lloyd’s Register certification for a product, visit
ni.com/certification and search for the LR certificate, or look for the
Lloyd’s Register mark on the product.
Caution In order to meet the EMC requirements for marine applications, install the product in a shielded enclosure with shielded and/or filtered power and input/output ports. In addition, take precautions when designing, selecting, and installing measurement probes and cables to ensure that the desired EMC performance is attained.
Preparing the Environment
Ensure that the environment in which you are using the NI 9775 meets the following specifications.
- Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C
- Operating humidity (IEC 60068-2-78) 10% RH to 90% RH, noncondensing
- Pollution Degree 2
- Maximum altitude 5,000 m
Indoor use only.
Note Refer to the device datasheet on
ni.com/manuals for complete specifications.
NI 9775 Pinout
Table 1. Signal Descriptions
Signal | Description |
---|---|
AI | Analog input signal connection |
CHASSIS GND | Chassis ground connection |
Single-Ended Connections
NI 9775 Connection Guidelines
Make sure that devices you connect to the NI 9775 are compatible with the module specifications.
Overvoltage Protection
The NI 9775 provides overvoltage protection for each channel.
Note Refer to the device datasheet on ni.com/manuals for more information about overvoltage protection.
Where to Go Next
C Series Documentation & Resources
ni.com/info cseriesdoc
Services
ni.com/services
Located at ni.com/manuals
Installs with the software
Worldwide Support and Services
The NI website is your complete resource for technical support. At
ni.com/support, you have access to everything from
troubleshooting and application development self-help resources to email and
phone assistance from NI Application Engineers.
Visit ni.com/services for NI Factory Installation
Services, repairs, extended warranty, and other services.
Visit ni.com/register to register your NI product.
Product registration facilitates technical support and ensures that you
receive important information updates from NI.
A Declaration of Conformity (DoC) is our claim of compliance with the Council
of the European Communities using the manufacturer’s declaration of
conformity. This system affords the user protection for electromagnetic
compatibility (EMC) and product safety. You can obtain the DoC for your
product by visiting ni.com/certification. If
your product supports calibration, you can obtain the calibration certificate
for your product at ni.com/calibration. NI
corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices
located around the world. For telephone support in the United States, create
your service request at ni.com/support or dial 1 866
ASK MYNI (275 6964). For telephone support outside the United States, visit
the Worldwide Offices section of ni.com/niglobal to
access the branch office websites, which provide up-to-date contact
information, support phone numbers, email addresses, and current events.
Refer to the NI Trademarks and Logo Guidelines at
ni.com/trademarks for information on NI
trademarks. Other product and company names mentioned herein are trademarks or
trade names of their respective companies. For patents covering NI
products/technology, refer to the appropriate location: Help»Patents in your
software, the patents.txt file on your media, or the National Instruments
Patent Notice at ni.com/patents. You can find
information about end-user license agreements (EULAs) and third-party legal
notices in the readme file for your NI product.
Refer to the Export Compliance Information at ni.com/legal/export-
compliance for the NI global trade
compliance policy and how to obtain relevant HTS codes, ECCNs, and other
import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE
ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY
ERRORS. U.S. Government Customers: The data contained in this manual was
developed at private expense and is subject to the applicable limited rights
and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014,
and DFAR 252.227-7015.
© 2016 National Instruments. All rights reserved.
377101A-01 Nov16
References
- Engineer Ambitiously - NI
- Engineer Ambitiously - NI
- Calibration Services - NI
- Product Certifications - NI
- Software and Driver Downloads - NI
- Using Info Codes - NI
- Trade Compliance - NI
- Product Documentation - NI
- Contact Us - NI
- National Instruments Patents - NI
- Log In - National Instruments
- NI Services - NI
- Support - NI
- NI Trademarks and Logo Guidelines - NI
- Calibration Services - NI
- Product Certifications - NI
- Software and Driver Downloads - NI
- Product Documentation - NI
- Product Documentation - NI
- Contact Us - NI
- Log In - National Instruments
- NI Services - NI
- Support - NI
- NI-9775 National Instruments Digitizer Module | Apex Waves
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>