Husqvarna S13 Dust Collector Medium H Class User Manual

October 30, 2023
Husqvarna

Husqvarna S13 Dust Collector Medium H Class User Manual
Husqvarna S13 Dust Collector Medium H Class

Please read the operator’s manual carefully and make sure you understand the instructions before using the machine.

SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the following:

WARNING – To reduce the risk of fire, electric shock or injury:

  • Cables damaged through crushing or splitting can be dangerous if used and should be replaced immediately. Risk of personal injury.

  • Make sure the assembly area is firm, so the dust extractor does not tip over. Risk of personal and material injury.

  • Risk of pinching when handling the toggle fasteners.

  • The machine must not be used in environments where explosive gases may be present. Serious risk of explosion.

  • Improper connection of the equipment-grounding conductor can result in a risk of electrical shock.
    Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the machine. If it will not fit the outlet. Have a proper outlet installed by a qualified electrician.

  • Before using the machine, make sure that the power & voltage corresponds with the voltage shown on the machines rating plate.

  • Do not leave machine when plugged in. Unplug cord from outlet when not in use and before cleaning or servicing machine.

  • Do not use outdoors or on wet surface, this machine is for indoor and dry use only.

  • Do not allow to use as a toy. Close attention is necessary when used by or near children.

  • Use only as described in this manual. Use only manufacturers recommended attachments.

  • Operators shall be adequately instructed on the use of the machine

  • This machine is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.

  • Do not use with damaged cord or plug. If the machine is not working as it should, has been dropped, damaged, left outdoors or dropped in water. Make sure it is repaired by a qualified person.

  • Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners. Do not run the machine over cord. Keep cord away from heated surfaces.

  • Do not unplug by pulling on cord. To unplug, grasp the plug. Not the cord.

  • Make sure the cord is unplugged when performing service or maintenance to the product.

  • Do not handle plug or machine with wet hands.

  • Regularly inspect cord and plug for damage. If cord is damaged, it must be replaced by a qualified person in order to avoid hazard.

  • Do not put any object into openings. Do not use with any opening blocked (accept during filter cleaning procedure). Keep free of dust, hair and anything that may reduce airflow.

  • Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.

  • Turn off all controls before unplugging.

  • Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.

  • Do not pick up any type of liquids.

  • Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.

  • Use extra care when cleaning on stairs.

  • Do not use without dust bag and/or filters in place. Replace collection system and/or filters as described
    in manual.

  • If using an extension cord make sure the cord rating is suitable for this machine.

  • Do not modify machine from its original design.

  • Keep children and unauthorized persons away from machine when in use.

  • All repairs must be performed by a qualified service person. Use only manufacturer-supplied or equivalent replacement parts.

  • Do not expose machine to rain or moisture. Store indoors only.

  • Connect to a properly grounded outlet only. See grounding instructions.

  • Make sure that you read and understand the instructions for the main product to ensure that you know what personal equipment to wear, what safety equipment to use and how to work in a safe mode.

THERMAL PROTECTION

  • The dust extractor is equipped with a safety thermal protector to prevent motor from overheating.Should thermal protector activate, turn off machine, unplug power cord and check for full dust bag,
    vacuum hose clog or filter blockage. It may take up to 45 minutes for the thermal protector to reset.

GROUNDING INSTRUCTION

  • The dust extractor must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. The dust extractor is equipped
    with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted
    into an appropriate outlet that is properly installed and grounded in accordance with all local codes and  ordinances.

SAFETY LABEL

  • The following label appears on the machine, next to the machines rating plate. Replace label if it is missing, becomes damaged or illegible. Failure to follow this warning label may result in fire, electric shock or injury

WARNING:
To reduce the risk of electric shock. Do not use outdoors or on wet surfaces. To reduce the risk of  electric shock, unplug before cleaning or servicing.

Type plate

CHusqvarn
S13


Intertek
400t590
CONFORMS TO UL STI11017
CERTIFIED TO CSA STD
C22.2 No.243-10

10130V ?A
100w S0/60Hz;
?m3/h 28kg

s/m: YYYY WWXOOKX
P/n: 987654321

HUSQUARNA AB
SE-56182 HUSKVARNA
SWEDEN
MADE INCHINA

CHusqvarn
S26


Intertek
400t590
CONFORMS TO UL STI11017
CERTIFIED TO CSA STD
C22.2 No.243-10

110130V ?A
2600 W 50/60Hz
?m3/h 47kg

s/m: YYYY WWXOOKX
P/n: 987654321

HUSQUARNA AB
SE-56182 HUSKVARNA
SWEDEN
MADE INCHINA

CHusqvarn
S36


Intertek
400t590
CONFORMS TO UL STI11017
CERTIFIED TO CSA STD
C22.2 No.243-10

20260v 32A
3600 W 50/60Hz
?m3/h 66kg

s/m: YYYY WWXOOKX
P/n: 987654321

HUSQUARNA AB
SE-56182 HUSKVARNA
SWEDEN
MADE INCHINA

UNPACKING

‘When unpacking the machine, please check that the following accessories are included:

  • The hose with end fittings.
  • Wand
  • Floor nozzle.

If any of the above-mentioned parts are missing, please contact your local distributor or our sales representative. For models that do not already have the front casters assembled due to packaging limitations. Assemble the front casters using the using bolt or nut and washer that are included in the package depending on your application. Protect the environment: Please dispose of packaging materials and used machine components in an environmentally safe way according to local disposal regulations. Always remember to recycle.

Product overview

S13

Product overview

S26

Product overview

  1. Hose
  2. Suction Pipe
  3. Floor tool
  4. Rubber blades

S36

Product overview

FUNCTION

The machine is designed for vacuuming and separating dry, non-combustible dust with an
explosion limit value of >0.1mg/m’.
The dust extractor is started by the switch.

Type Models without automatic start Autostart function models
Red switch 2 step 0: Motor off, 1: Motor on N/A
Black switch 3 step) N/A 0: Motor off, 1: Motor on, 2: Automatic start

Dust-laden air is then sucked through the inlet valve at high speed via the suction hose. The air is slowed down
by the cyclone and coarse dust particles are separated out, partly by centrifugal force and partly by gravity. Air
and finer particles then pass through the double filter system where separation is made. The machine is designed
for filter cleaning by reverse air pulse. The separated dust accumulates in the cyclone until the machine is switched off, when it drops through the bottom flap into the plastic bag. The filter cleaning process is not completed before it is clear that the dust inside the tank has fallen down into the collection bag. In some extreme cases the adhesive ability of the dust must be broken manually. This can be done by hitting the dust through the bag or tapping the tank using i.e. a rubber hammer.
Automatic start function: When you use the dust extractor together with another machine, there is an
electrical outlet on the dust extractor. Connect the machine to this outlet. Then when you start it up the dust
extractor will also start after Sorms55. 1-2 seconds. When you turn it off, the dust extractor will continue to run
for approximately 10 seconds. To empty the hose. Then stop

FILTER CLEANING

he filter must be cleaned from time to time. This must be done before changing the bag collection system and
should also be done when work is completed or when there is poor suction.
Procedure: Cover the inlet, if applicable, use attached cover. First let the machine build up vacuum for four to
five seconds then quickly push down on the key and release it. Repeat the procedure five times. It is important to
let the machine rebuild the vacuum in between every repetition.
Turn off the motor and wait until it stops completely, then uncover the inlet.
If suction remains poor, the pre-filter needs to be replaced. If suction still remains poor afterwards, the Hepa
filters needs to be replaced. See instructions in chapter 6. FILTER CHANGE.

UST STORAGE SYSTEM

The dust extractors are mainly equipped with Longopac system for effective dust storage or a regular plastic bag
system depending on model. Longopac is a 22 m long plastic tube that will be divided into plastic bags using the
zip ties attached with the machine.
To assemble a new Longopac bag: Release the belt holding the last bag. Remove the holder, put in a new
Longopac bag & pull out the inner end upwards. Assemble the holder on to the machine and strap the opening
facing upwards with the belt. Pull down the outside end and close it using a zip tie.
All dust extractors can be used with original Husqvarna dust bags for single use. Also all models can be fitted
with the longopac system. Only change Longopac or regular bag after filter cleaning cycle have been completed.

FILTER CHANGE

Risk of dust dispersion — Use personal safety equipment Unhealthy dust can be spread during filter change. Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask conforming to protection class FFP3.

Wear breathing mask
Wear breathing mask

Wear ear protection
Wear ear protection
Wear protective glasses
Wear protective glasses

WARNING
Remember to switch off the machine and pull the plug out of the outlet before servicing.
Pre-filter
Loosen the 3 clamps and remove the top. Take the bag from the new filter. Lift out the filter and place it gently in a plastic bag. This bag must be properly disposed. Insert a new filter.
Important:
If you are removing the Pre-filter in order to clean it. Hitting the filter with force or use of compressed air will
destroy the filter. It can handle water, but high pressure water cleaning will destroy it.
Hepa Filter
Loosen the two nuts on each filter cover cap. Carefully lift the filter into a clean plastic bag, use the bag from the
new filter. This bag must be properly disposed. Insert a new filter in reverse order.
Important:
Hepa filters can’t be cleaned, trying this might destroy it. When installing the replacement filter, make sure to
not touch the inside of the filter. Any kind of force/damage on the inside of filter media will destroy the new
filter.
Recommended intervals for filter change: Socks filter every 6 months and Hepa filter every 12 month.

SERVICE

  • When cleaning and servicing the machine, you must switch off the machine and remove the plug from the outlet.
  • Avoid cleaning with a high pressure cleaner. If necessary, do not direct at the openings on the machine, especially the opening for cooling air.
  • Before moving the machine from the work area, the machine must be cleaned.
  • All other equipment must be regarded as contaminated and be treated thereafter.
  • If possible, use a special suitable room.
  • Proper personnel protective equipment must be used. Dust can be spread when the coarse filter and the absolute filter are replaced that can be hazardous to health. Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask conforming to protection class FFP3.
  • All parts which are contaminated after service must be properly disposed of in plastic bags according to all regulations.
  • If the machine has to be used for other purposes, it is extremely important that the machine is cleaned, to avoid the spread of hazardous dust.
  • Do not puncture the Hepa filter. Risk of dust dispersion.

Replacement parts, Filters and Dust collection system

Part no: Description S 13 S26 S36
590426101 Longopac (4-bags) 1 1 1
590396101 Plastic bags (25-pcs) 1 1 1
590397401 Pre-filter S13 1 N/A N/A
590426501 Pre-filter S26 N/A 1 N/A
590448501 Pre-filter S36 N/A N/A 1
590396601 HEPA FILTER S-LINE 1 2 3
590402901 HEPA FILTER S-LINE USA 1 2 3

PROBLEM SOLVING

The dust extractors are designed and manufactured for severe environments and tasks, but the user must note that
the machine must be protected from knocks and blows. Filter, seals, attachments, and connections are carefully
adapted and selected with regard to the operator’s work environment. Therefore, the operator and service personnel must treat the machine with care in order for it to work correctly for many years.

Issue Cause Solution
Motor doesn’t start No power Plug in machine
Cable defective Replace cable
Switch defective Replace switch
Soft start defective Replace soft start
Motor stops immediately after starting Wrong fuse Connect to correct fuse
Shortcut in cable/machine Order service
Motor runs but there is not suction Hose not connected Connect hose
Hose clogged/blocked Clean hose
No dust collection bag Fit dust collection system
Motor runs but poor suction Hole in hose Replace hose
Filter clogged Clean filter/Replace filter
Loose top cover Adjust
Defective gaskets Replace affected gaskets
Dust blown from motor Wrongly assembled ordamaged filter system

Adjust/Replace filters
Abnormal noise| | Order service

SAVE THESE INSTRUCTIONS!

TECHNICAL DATA

Data| Unit| S13 120 V| S26 120 V| S26 230 V| S36 120 V| S36 230 V
---|---|---|---|---|---|---
Voltage
(single phase)| V| 120| 120| 230| 120| 230
Power (max)| kW| 1,2| 2,4| 2,4| 3,2| 3.6
HP| 1,6| 3,2| 3,2| 3,2| 4,8
Current (max)| A| 10,0| 20,0| 10,0| 20,0| 15,7
airflow (max)| m3/h| 219| 438| 438| 485| 600
cfm| 129| 258| 258| 285| 353
Vacuum (max)| kPa| 24| 24| 24| 18| 28
Water lift| In| 100| 100| 100| 80| 110
Main hose| Metric
(uun)| 4m x 38| 7,5m x 51| 7,5m x 51| 10m x 63| 10mx 63
USCS| 13′ x 1,5″| 24′ x 2″| 2t x 2″| 32′ x 2,5″| 32′ x 2,5″
Inlet| Metric
(mm)| 51| 63| 63| 63| 63
USCS| | 2,5″| 2,5″| 2,5″| 2,5″
Pre-filter
EN779-F8| %
@ lum| >99.5| >99,5| >99,5| >99,5| >99,5
Pre-filter area| Metric| 1.5 mz| 3 m2| 3 mz| 4.5 in,| 4.5 ml
USCS| 16 W| 32 W| 32 W| 48 W| 48 W
Rep filter
EN1822-H13| 99,99%
@0.3um| I| 2| 2| 3| 3
Total HEPA filter
area| Metric| 1 r m2| 2,4 in2| 2,4 mz| 3,6 in2| 3,6 in2
USCS| 13 ft’| 26 ft’| 26 ft,| 39 ftz| 39 112
Sound level| dB(a)| 70| 70| 70| 70| 70
Dust collection
system| Type| Plastic bag| Longopac| Longopac| Longopac| Longopac
Dimensions
(L W H)| Metrk
(      )| 6801400×1100| 756x546x1275| 756x546x1275| 840x620x1500| 840x620x1500
USCS| 26×15,8×43,3 “| 29×21,5×50,2″| 29×21,5×50,2″| 33×24,5×60″| 33×24,5×60″
Weight| Metric| 29 kg| 47 kg| 47 kg| 63 kg| 63 kg
USCS| 66 Ws| 105 lbs| 105 lbs| 140 lbs| 140 Is

PLUGS

MODEL| PLUG TYPE| RECEP TACLE TYPE| RECEPTACLE MAX AMPS| CABLE & PLUG MAX AMPS
---|---|---|---|---
S13120 V| NEMA 5-15P| N/A| N/A| 15 A
S13 230 V| SOCKET FGROUNDED| SOCKET F| 5 A| 10 A
S26 120 V| NEMA 5-20P| N/A| N/A| 20 A
S26 230 V US| NEMA L6-15P| N/A| N/A| 15 A
S26 230 V| SOCKET FGROUNDED| N/A| N/A| 10 A
S36120 V US| NEMA 5-20P| N/A| N/A| 20 A
S36 230 V30A| NEMA L6-30P| NEMA L6-30| 20 A| 30 A
S36 230 V50A| NEMA L6-50P| NEMA L6-50| 35 A| 50 A
S36 230 V| IEC 60309 16 A| N/A| N/A| 16A

DIGRAM

The grounding methods of S13 120V machine follow the UL1017 section 11.3.1 part b) as below:
For a grounded, cord-connected appliance rated less than 15 A and intended for use on a nominal 120-V supply circuit, the instructions in either item 1 or 2:

  1. This appliance is for use on a nominal 120-V circuit, and has a grounded plug that looks like the plug illustrated in sketch A in Figure 20. A temporary adaptor that looks like the adaptor illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (sketch A) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw. Exception: In Canada, the use of a temporary adaptor is not permitted by the Canadian Electrical Code, C22.1.
  2. This appliance is for use on a nominal 120-V circuit and has a grounding attachment plug that looks like the
    plug illustrated in sketch A in Figure 20. Make sure that the appliance is connected to an outlet having the same
    configuration as the plug. No adaptor should be used with this appliance.
    The grounding methods of S26 120V, S26 230V, S36 120V US, S36 230V 30A AND S36 230V S0A follow the UL1017 section 11.3.1 part c) as below:
    For all other grounded, cord-connected appliances:
    This appliance is for use on a circuit having a nominal rating more than 120 V (or This appliance is rated more than 15 A and is for use on a circuit having a nominal rating of 120 V) and is factory-equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance. If the appliance must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel.

Grounding methods

Grounding methods

WARRANTY

All Husqvarna devices and accessories have a 12-month factory warranty for material and manufacturing defects. The warranty extends to 36 months when returning the attached warranty slip. Do not attempt to repair the suction apparatus without the consent of the manufacturer. The warranty does not cover defects which are the result of normal wear and tear, negligence, defective use, unauthorized repair or the suction apparatus being connected to the incorrect voltage. In the event of any complaint, the suction apparatus or an agreed part of it must be returned to us or our authorised representative for warranty examination and for any warranty repair or replacement.

www.husqvarnacp.com
Original instructions
1158771-26
2017-03-24

Husqvarna Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals