Please, read these instructions carefully before attempting installation Deliver this manual to the final user.
SECURITY ADVISE SYMBOLS
| ¡Attention, Danger, Safety Advice!
---|---
| Injuries risk!
****| Important information.
| Danger from electric current or high voltage!
| Danger! Do not stay underneath: Heavy load.
| Attention! Wear protective glasses UV-A: Ultraviolet radiation.
INSTALLATION
| Installation work, connection, disconnection, electrical wiring, mechanical
maintenance and service must be done by qualified people observing these
instructions and in accordance with all applicable norms and standards.
If the unit is operated with additional controller, please consider its
specific instructions.
---|---
| The electrical connection is made with a shuck connector. It is not
necessary to open the service panel to connect the equipment. The equipment
fixings are external (in the standard model, located at the top or rear of the
purifier). To make a repair or replacement it is necessary to open the
service side panel. (see repairs section).
A | B | C | D |
---|
10
(MIN)| 500
(MIN)| 500
(MIN)| 300
(MIN)
MIN. Recommended minimum distance.
Be careful, the more free space you give to the equipment, the better air
quality you can get. For this, it is necessary to respect the following
installation measures:
Suction plane: Minimum free area of 200mm (recommended to clear the maximum
space to facilitate the suction of particles).
Discharge plane: Minimum free area of 500mm (it is recommended to clear as
much space as possible to make it easier for the OH to spread throughout the
room (Dimension C).
Upper plane: Minimum separation with the ceiling of 10 mm (Dimension A).
Lower plane: Minimum free area of 300mm from cyclonic tank (cartridge
replacement and emptying of the cyclonic tank) (Dimension D).
Maintenance plane 500mm free area, recommended 1 meter.
Opposite plane to maintenance 10mm.
CONNECTION DIAGRAM
Power supply
The Cyclonic air purifier has a 3-meter, 3-way cable (line, neutral and earth)
that must be connected to a 230Vx1 50/60Hz power outlet with the Shuck-type
plug that it incorporates.
A switch can be connected between the equipment and the power outlet. In this
way, you can unplug the equipment easily.
Fixations
The equipment has four fixing angles located at each corner of the box (see
location in the model characteristics section).
The anchor must be sized according to the weights of the Cyclohnic indicated
on the technical data page.
Installation can be done using threaded studs, turnbuckles, or other supports.
See supports in accessories.
TRANSPORT AND STORAGE
ATTENTION! Heavy object.
Do not stand under the suspended load during its transport or assembly.
Store in a dry place protected from the elements. If the packaging is open,
cover the purifier to protect it from dust. Do not step on or place heavy
loads on it to avoid damage to the material.
Storage temperature between -20⁰C and +40⁰C.
When transporting the material, you must ensure that it is not damaged by the
forklift.
(possible penetration of the fork in the packaging). Observe the instructions
on the packaging.
Includes a consumable with disinfectant liquid (hydrogen peroxide solution).
| (EN) CAUTION: Causes skin irritation. Causes serious eye irritation. Keep
away from combustible materials. Wash hands and forearms thoroughly after
handling.
IN CASE OF CONTACT WITH EYES: Rinse cautiously with water for several minutes.
Remove contact lenses when they are present and can be done easily. Continue
with the wash.
IF SWALLOWED: Rinse mouth. Call a POISON CENTER or doctor/physician if you
feel unwell.
Store in a well ventilated place. Keep the recipient hermetically sealed. Keep
out of the reach of children. Dispose of contents/container at an approved
waste disposal facility.
---|---
OPERATING INSTRUCTIONS
To put the device into operation, it is only necessary to connect it to a voltage of 230Vx1 50/60Hz, as indicated in the electrical diagram on the next page. The operation of the equipment is without regulation. Once connected to the current, the fan will start operating at its maximum flow rate, the photocatalysis will start its function and, if the cartridge has been inserted, the device will generate OH.
ELECTRICAL SCHEMES
DATASHEET
Technical features
Specially designed to improve the air quality and minimize the transmission of
pathogens on livestock, diary or animal centers.
Combines a double patented purification technology through the generation of
hydroxyl radicals OH· and the effect of photocatalysis.
Innovative OH active technology with efficient production of hydroxyl
radicals, which sanitize both air and surfaces through a chain reaction.
Through Advanced Oxidation Processes (AOP) inactivates pathogenic
microorganisms (viruses and bacteria), improves air quality (reducing volatile
organic compounds and suspended particles) and eliminates odours.
Kleinian technology with photocatalytic action fans. UV-A rays, from the long-
life LED, act on the titanium dioxide of the turbine generating Reactive
Oxygen Species (ROS) that, through oxidation / reduction reactions, deactivate
a wide range of pathogenic microorganisms (viruses and bacteria). It
mineralizes most of the pollutants present in urban areas produced by vehicles
and industry (NOx, Sox, Coax, formaldehydes, VOCs, etc.).
Double filtration stages to catch air particles:
– Cyclone dust remover with collector.
– G4 (ZLM) according to EN779 standard.
Plug&play equipment without regulation.
Self-supporting stainless steel housing, extremely robust to guarantee a long
life in corrosive environments, prepared for ceiling suspended installation.
Aspiration through the cyclonic filter. The filter incorporates a tank with a
practical drain plug for maintenance when the tank is full.
Double inlet centrifugal fan driven by an external rotor motor with very low
consumption and noise level.
Dimensions
The equipment has a compact design, with total dimensions of 533 x 413 x 949 (mm), including the cyclone collector and the dust and particle container tank.
Functioning
The cyclone dust collector captures the large particles and precipitates them into the container. The air that passes through the equipment is filtered and subsequently purified due to the action of photocatalytic technology. Also, Cyclohnic generates hydroxyl radicals that expand through a chain reaction (active technology) to purify the air and surfaces in the room where it is installed.
Applications
Cyclonic is suitable for all types of livestock farms, whether for breeding,
housing or feeding animals.
It is ideal for all types of livestock.
MAINTENANCE INSTRUCTIONS
| For safety reasons, before proceeding with cleaning, disconnect the device
from the current.
---|---
| Do not open the lateral service panel if the current is still connected
(risk of electric shock, entrapment in the fans and UV-A light glare).
**| Repairs must be carried out exclusively by authorized personnel.
Indicative maintenance frequency**
N° Action| Action| Frequency
1| G4 filter replacement| Recommended at 300 h of usage
2| Tank emptying| Check level when filter G4 is replaced
3| Exterior cleaning| Bimonthly (recommended monthly)
4| Interior cleaning| Bimensal (recommended monthly)
5| Cartridge replacement| Quarterly
6| Electrical consumption and visual checking| Annual (recommended biannual)
G4 filter replacement
Disconnect the equipment from the current before carrying out maintenance.
Remove the maintenance lateral panel and remove the dirty filter.
Fit the new filter and replace the side panel.
Tank draining
Check the fill level of the tank, if it is above half, disconnect the
equipment from the current, unscrew the cap and empty the content into a
container for proper processing.
Exterior cleaning
The cleaning of the exterior of the equipment should be carried out with a
damp cloth and a conventional detergent. Do not use caustic or acid-containing
detergents.
Interior cleaning
It is only necessary to clean the area before the G4 filter, the fan area is a
filtered area that does not require maintenance.
To carry out cleaning, disconnect the equipment from the current and remove
the maintenance panel. Next, clean the interior with a vacuum cleaner or damp
cloth.
Cartridge replacement
Periodically check the level of the cartridge and, once finished, replace it
with a new one according to the following image:
Electrical consumption and visual checking
With the equipment running, check that the UV LED is on (the color inside the
fan is seen as violet).
Remove maintenance panel and check that electrical connections are secure.
Remove maintenance panel and check that electrical connections are secure.
Write down the consumption value of the product label located at the lateral
service panel.
Using an ammeter, verify that the amperage consumption of the equipment is
between 85% and 110% of the value indicated on the product label.
REPAIRS AND REPLACEMENTS
Assembly and electrical connection must be carried out exclusively by
specialized professionals and in compliance with these instructions.
Before carrying out any repair, it is necessary to:
| Notify staff and indicate that work is being done.
Disconnect the current and protect the circuit breaker.
---|---
| Make sure there is no voltage to the unit.
| Make sure the fan has stopped.
Use only original spare parts.
Lateral service panel opening
Remove the four panel fixing screws and then remove the equipment.
Motor replacement
Before replacing the motor, it is necessary to warn that it is working,
disconnect from the current (1), make sure that there is no voltage and that
the turbine does not turn.
Remove the lateral service panel (2) and G4 filter (3) for greater
maneuverability.
Disconnect the power cable from the terminal block (4), as well as the OH
generator power supply (5). Unscrew the four fastening screws of the fan (6)
and remove it from the device (7).
Finally, proceed in reverse order to fit the new motor.
ACCESSORIES
Supports and shock absorbers according to installation (see references in the attached document).
FAULTS ANS SOLUTIONS
Electrical feeding
If the equipment does not work, the error is most likely due to an incorrect
terminal power supply.
1 – Check that it has been connected to a functional electrical outlet.
2 – Check that the current is compatible with the equipment and that the
terminal block cables are connected according to the electrical diagram
specified in this manual.
3- Check that voltage (230Vx1) reaches the equipment. If not, check the power
cables. Considerations:
– If the equipment stops recirculating air, check the level of the cyclone
filter tank. If it is completely full, it must be emptied so that it can
perform the function and allow air to circulate through the equipment.
– If, once the tank has been emptied, the fan still does not work, it must be
replaced with a new one. – If the UV light does not work, but the rest of the
components do, check that the cables of the UV Source are correctly connected.
– If the fan turns but does not blow air and the cyclonic filter tank is
empty, the G4 filter must be changed.
COMFORMITY DECLARATION
Manufacturer Motors i Ventiladors S.L. (AIRTECNICS)
We declare, under our sole responsibility, that the product
Air and Surfaces Purification Equipment
with models Cyclonic
is/are developed, designed and manufactured in accordance with the following
directive(s)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Restriction Certain Hazardous Substances Directive 2011/65/EU (RoHS)
Eco-design Energy-related Products Directive 2009/125/EC
Applying the following harmonized standards in particular
LVD: EN 60335-1:2012 + A11:2014 + A13:2017 +A1:2019 + A14:2019 +
A2:2019 + A15:2021
EN 60335-2-65:2003 + A1:2008 + A11:2012
EMC: EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-6-1:2007
EN 61000-6-3:2007+ A1:2011
RoHS: EN 50581:2012
Date 13/11/2020
Name Jordi Hierro 3 .
Position Technical Manager
IDENTIFICATOR
Conca de Barbara 6 – Pal de la Bruguier
08211 Castellar del Valles – BCN (SPAIN)
Tel +34 93 7159988 www.airtecnics.com
All air purifiers are identified by a unique serial number, printed on a label
located inside the service door. It also indicates the model of the purifier
and its technical characteristics (flow rate, technical data of the fans).
It is essential to have this number to facilitate possible spare parts or
technical information on the purifier in question.
WARRANTY
The warranty extends for one calendar year from the date of delivery. The
guarantee is limited to repairing or replacing from our warehouse the products
that eventually suffer breakdowns attributable to production defects.
Installation costs are borne by the buyer. Products that in our opinion have
been used improperly, handled incorrectly, improperly installed, connected to
voltages other than the nominal, modified or repaired by unauthorized
personnel, or that have suffered damage during transport, are excluded from
any guarantee.
For the validity of this guarantee, it will be essential that it be correctly
completed and accompanied by the invoice that proves the date of purchase. In
the case of being tampered with, it will lose its validity.
It is the sole responsibility of the buyer to take the necessary security
measures so that, in the event of a failure of one of the products, no damage
occurs to third-party equipment, facilities or people.
Warranty card
Purification data:
Model:…………………………………………….
Invoice date:……………………………………
Serial number:………………………………..
Invoice number:……………………………….
Buyer data:
Name:………………………………………………
Address:……………………………………………
Country:……………………………………………
Telephone:………………………………………
Fax:…………………………………………………
Seller data:
Name: ……………………………………………..
Address: …………………………………………..
Country:…………………………………………..
Telephone:……………………………………….
Fax:…………………………………………………
Seal and sign from the buyer
Seal and sign from the seller
If you detect any errors in this manual, we will be happy to receive your
comments, it helps us to continue improving. Airtècnics reserves the right to
modify any of the specifications in this manual.
Conca de Barberà, 6 – Pol. Ind. Pla de la Bruguera
E-08211 Castellar del Vallès (Barcelona) Spain
☏ + 34 93 715 99 88
airtecnics@airtecnics.com
www.airtecnics.comhttps://www.airtecnics.com/file-
qr/eyJpdiI6IkRob2ZjQ3F1RlRuN3VMVUdmc1VLK2c9PSIsInZhbHVlIjoiWmdLS04yK25iVVNUWXlkaU54dmpSNnpGMmdtOVQyaldqWTdNT1V5QkQ1QUI5TENPeTd5SXBocmtMSG0zVkYzXC92dXN5ZjVTbWRpMXhBWU5RcWlXK3NET2duTUhxQjErUVk3TjdQQURYcjB3d2Y2Zm9PZXJaVVVzcEM4ZkNzekVIIiwibWFjIjoiNDNmMmRmODBjZmY3ZWY5ZmJjM2JkYmUyM2FlZmFjMWM2YTBkZWZlMWRiZTQ2NGUxZWZlOGY5ZTMyOWE3NjQ2ZiJ9
AIRWEL68005-R0(04/02/22)
We reserve the right to change design and specifications without prior
notice.
Documents / Resources
|
airtecnics Purification Unit
Cyclohnic
[pdf] Instruction Manual
Purification Unit Cyclohnic, Purification, Unit Cyclohnic, Cyclohnic
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>