Logicbus I-2541 Optical Fiber Serial Converter User Guide

October 30, 2023
Logicbus

Logicbus I-2541 Optical Fiber Serial Converter User Guide
Optical Fiber Serial Converter

General Description

The I-2541 is an RS-232/422/485 to fiber optic converter that ensures data transmission security by using fiber optic transmission technology to provide immunity from EMI/RFI interference. The I-2541 is designed for RS-232/422 point-to-point connections and RS-485 multi-drop applications which require a signal to be transmitted for distances of up to 2Km (6,600 ft), and is a perfect solution in applications where transmission must be protected from electrical exposure, power surges, lightning strikes or chemical corrosion.

Specifications

  • Fiber Port: ST (Multi-mode)
  • Wavelength: 850nm
  • Fiber Cable: 62.5/125µm
  • Speed: Internal “Self Tuner”, auto switching Baud Rate, 300~115200 bps
  • Transmission Distance: Signals can be transmitted up to 2Km.
  • Isolation voltage: 3000V DC
  • Optical isolation: 3570Vrms
  • DIN rail mount for industrial usage
  • Provides LEDs for network and power monitoring
  • Dimensions: 32.30 x 99.00 x 77.50 mm (w x h x d)
  • Power requirements: Unregulated +10V DC ~ +30V DC.
  • Power consumption: 2.0W max.
  • ESD Protection:
    4KV Contact Discharge
    8KV Air-Gap Discharge

Connectors & Cables

Overview

Tenninal
NO.
| Pin name
---|---
TxD| F iber Tx D
RxD| Fiber RxD
1| Tx+/DATA +
2| Tx-/DATA-
3| Rx +
4| Rx-
5| NC
6|  G ND
7| TxD
8| RxD

RS-232/422/485 Converter connection

Serial communication

RS-232 Signals| TxD, RxD, GND
RS-422 Signals| Tx+, Tx-, Rx+, Rx-
RS-485 Signals| Data+, Data-
Baud Rate| 300bps to 115.2kbps

Fiber Cables
The I-2541 uses a wavelength of 850nm and also supports MM (multimode) fiber cables. A 62.5/125mm MM cable is recommended.

Interpreting the LED Indicators

LED Status State Interpretation
POWER Power status ON Converter is on.
OFF Converter is off.
TD Transit Data ON Transiting on Fiber port.
OFF No link or the link is faulty.
RD Receive Data ON Receiving on Fiber port
OFF No link or the link is faulty.

Making Network Connections
Important note: RS-232/485/422 protocols cannot be used simultaneously.

The RS-485 pin assignment of the I-2541

TerminalNumber| TxD| RxD| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---|---|---
Pin Name| Fiber TxD| Fiber RxD| DATA+| DATA-| | | | | |

Network Connections

The RS-422 pin assignment of the I-2541

TerminalNumber| TxD| RxD| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---|---|---
Pin Name| Fiber TxD| Fiber RxD| Tx+| Tx-| Rx+| Rx-| | | |

Network Connections

The RS-232 pin assignment of the I-2541

TerminalNumber| TxD| RxD| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---|---|---
Pin Name| Fiber TxD| Fiber RxD| | | | | | GND| TxD| RxD

Network Connections

All pin assignments for the I-2541

TerminalNumber| TxD| RxD| 1| 2| 3| 4| 5| 6| 7| 8
---|---|---|---|---|---|---|---|---|---|---
Pin Name| Fiber TxD| Fiber RxD| Tx+ DATA+| Tx- DATA-| Rx+| Rx-| NC| GND| TxD| RxD

Note: RS-232/485/422 protocols cannot be used simultaneously.

Network Connections

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals