KARCHER BP Series Booster Pump for Garden User Manual

October 30, 2023
Karcher

Table of Contents

KARCHER BP Series Booster Pump for Garden User Manual
KARCHER BP Series Booster Pump for Garden

General notes

Read these original operating instructions and the enclosed safety instructions before using the device for the first time. Proceed accordingly. Keep both books for future reference or for future owners.

Intended use

Please observe the requirements of EN 1717 when connecting this product to the drinking water network and contact your sanitation specialists if you have any questions.
This device has been developed for private use and is not intended for the load imposed by commercial use. The device is primarily intended for use in the garden and provides constant pressure for garden watering.
When connecting sprinklers, a maximum of the following areas can be irrigated:

  • BP 4.500 Garden: 400 m2
  • BP 5.000 Garden: 550 m2
  • BP 6.000 Garden: 900 m2
  • BP 7.000 Garden: 1000 m2

CAUTION

Risk of injury!
Risk of injury from toxic substances. Do not drink water that has been pumped by the pump!

Permissible feed fluids

Permissible feed fluids:

  • Processed water

  • Well water

  • Spring water

  • Rain water

  • Swimming pool water with intended dosage of additives

The temperature of the delivered liquid must not exceed 35 °C.

Improper use

Note

The manufacturer accepts no liability for possible damage caused by improper use or incorrect operation.

Hazard levels

DANGER

  • Indication of an imminent threat of danger that will lead to severe injuries or even death.

WARNING

  • Indication of a potentially dangerous situation that may lead to severe injuries or even death.

CAUTION

  • Indication of a potentially dangerous situation that may lead to minor injuries.

ATTENTION

  • Indication of a potentially dangerous situation that may lead to damage to property

Environmental protection

The packing materials can be recycled. Please dispose of packaging in accordance with the environmental regulations.

Electrical and electronic appliances contain valuable, recyclable materials and often components such as batteries, rechargeable batteries or oil, which – if handled or disposed of incorrectly – can pose a potential threat to human health and the environment. However, these components are required for the correct operation of the appliance. Appliances marked by this symbol are not allowed to be disposed of together with the household rubbish.

Notes on the content materials (REACH)

Current information on content materials can be found at: www.kaercher.com/REACH

Accessories and spare parts

Only use original accessories and original spare parts. They ensure that

the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.

Scope of delivery

The scope of delivery for the appliance is shown on thepackaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.

Warranty

The warranty conditions issued by our sales company
responsible apply in all countries. We shall remedy possible malfunctions on your device within the warranty period free of cost, provided that a material or manufacturing defect is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised customer service site.
(See overleaf for the address)

Description of the device

The maximum amount of equipment is described in these operating

instructions. Depending on the model used, there are differences in the scope of delivery (see packaging).
For the illustrations, refer to the graphics page

**Illustration A


**

  1. Cap, 2-way connection adapter

  2. 2-way connection adapter for pumps G 1 (not included with BP 4.500 Garden)

  3. Connection adapter for pumps G 1 (included twice with BP 4.500 Garden)

  4. Sealing plug

  5. Connection G 1 (33.3 mm) suction line (inlet)

  6. Filling nozzle with cap

  7. Connection G 1 (33.3 mm) pressure line (outlet)

  8. ON/OFF switch

  9. Water drain valve

  10. **Tap connection G 1

  11. **Coupling with Aqua Stop

  12. **Coupling

  13. **Syringe

  14. *Suction hose set incl. 3.5 m ready-to-connect, vacuum-proof spiral hose with suction filter and backflow stop

  15. **Garden hose 1/2″ 20 m

  16. Power supply cable with plug

* Only accessories included with Set and Set Plus.

** Only accessories included with Set Plus.

Startup

We recommend using only original Kärcher suction hoses, filter components

and hose connections. Using components from other manufacturers can lead to malfunctions when sucking the feed fluid, especially when using bayonet connection systems.

Before initial startup

Preparation

  • Remove the sealing plug.

  • Screw the connection adapter into the suction connection of the pump (inlet). Manually tighten.

  • Connect a vacuum-tight suction hose

**Illustration B

Before initial startup
**

Note

If the water is dirty, we recommend fitting a pre-filter (see Special accessories) between the check valve and the suction hose.
Illustration C
Before initial startup

Note

To shorten the re-suction time, use a suction hose with backflow stop. This prevents the suction hose from emptying after use (see Special accessories).

  • Screw the connection adapter into the pressure connection of the pump (outlet). Manually tighten.

**Illustration D

**Before initial startup

  • Open the filling nozzle cap.

**Illustration E

**Before initial startup

  • Fill the pump with water until it overflows.

**Illustration F

Before initial startup
**

Operation

  1. Plug the mains plug into a mains socket.

  2. Switch the device on with the ON/OFF switch.

  3. To shorten the suction time, raise the pressure hose approx. 1 m.

**Illustration I

**Operation

  1. Wait until the pump simultaneously sucks and delivers.

CAUTION

Danger due to dry running

Dry running damages the pump. Do not let the pump run dry!

  1. Do not leave the pump unattended during operation.

ATTENTION

Risk of injury. The system is pressurized! Risk of injury.
(for pressure see chapter “Technical data”)

Ending operation

  1. Switch off the device at the ON/OFF switch.

  2. Pull the mains plug out of the socket.

Care and maintenance

DANGER
Danger of electric shock.
Always switch the devie off and disconnect the mains plug before working on the device. The device is maintenance-free.

Rinse

Note
Rinse the pump with clear water after each use when pumping water with additives.

Transport

CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the device (see chapter Specifications) and secure it accordingly when transporting it in vehicles.

Manual transport
  1. Roll up the cable.
  2. Lift and carry the device by the carrying handle.
Transport in vehicles
  1. Secure the device against slipping and tipping over.

CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the device (see technical data) and secure it accordingly when transporting it in vehicles.

Storage

CAUTION
Risk of injury and damage!
The device may tip over on sloping surfaces. Be aware of the weight of the device during storage.

  1. Store the device in a frost-protected place.
Storing the device
  1. Depressurise the device by opening the water removal connected to the pressure side (e.g. opening the garden sprayer).

  2. Empty the hoses.

  3. Remove suction line and pressure line.

  4. Drain the pump via the water drain valve.
    Illustration H
    Storing the device

  5. Store the device in a frost-protected place

Special accessories

You will find the possible special accessories on the last page of these operating instructions.

Troubleshooting guide

Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service

Fault Cause Rectification
Pump is running, but not delivering Air is in the pump.
  1. Check for correct startup (see chapter Preparation and Operation ).

Dirt particles block the suction area.|

  1. Pull the mains plug out of the socket.
  2. Clean the suction area.

The suction hose or the connection adapter is not correctly screwed in.|

  1. Check that the seals are fitted correctly.
  2. Manually tighten the suction hose and con- nection adapter.

The pre-filter is clogged.|

  1. Clean the pre-filter.

The pump does not start up, or stops suddenly during operation| The power supply is disconnected.|

  1. Check the fuses and the electrical connec- tions.

The pump capacity drops or is too low| The suction area is clogged.|

  1. Pull the mains plug out of the socket.
  2. Clean the suction area.

The delivery rate of the pump depends on the delivery head and the connected periphery.|

  1. Observe the max. delivery head (see chap- ter Specifications ), select a different hose diameter or a different hose length if nec- essary.

The cross-section on the pressure side is narrowed, e.g. due to the valve/ball tap not being fully open.|

  1. Open the valve/ball tap completely.

The hose is kinked on the pressure side.|

  1. Eliminate the kink points in the hose.

The pre-filter is clogged.|

  1. Clean the pre-filter.

Specifications

BP 4.500 Garden| BP 5.000 Garden| BP 6.000 Garden| BP 7.000 Garden
---|---|---|---
BP 4.500 Garden Set Plus| BP 5.000 Garden Set Plus| BP 6.000 Garden Set Plus|
Mains voltage| V| 230-240| 230-240| 230-240| 230-240
---|---|---|---|---|---
Power frequency| Hz| 50| 50| 50| 50
Nominal power| W| 550| 650| 1000| 1100
Maximum flow rate| l/h| 4500| 5000| 6000| 7000
Suction height (max.)| m| 8| 8| 8| 8
Pressure (max.)| MPa (bar)| 0,36 (3,6)| 0,40 (4,0)| 0,45 (4,5)| 0,5 (5,0)
Delivery height (max.)| m| 35| 40| 45| 50
Delivery temperature (max.)| °C| 35,0| 35,0| 35,0| 35,0
Particle size (max.) of permissible feed fluids| mm| 1| 1| 1| 1
Pump type| | Jet| Jet| Jet| Jet
| | | | |
Sound pressure level LpA| dB(A)| 56| 58| 69| 68
Guaranteed sound power level LWA| dB(A)| 71| 73| 84| 83
Dimensions and weights| | | | |
Weight (without accessories)| kg| 6,4| 7,0| 9,7| 10,0

Note
Reason for exception according to regulation (EU)
2019/1781 Annex I Section 2 (12): (j) Subject to technical modifications!

Characteristic curves

Characteristic curves
Characteristic curves

Declaration of Conformity

We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us. This declaration is invalidated by any changes made to the machine that are not approved by us.

Product: Pump
Type: 1.645-xxx

Currently applicable EU Directives
2006/42/EC (+2009/127/EC)
2014/30/EU
2000/14/EC
2011/65/EU
2009/125/EC

Commission Regulation(s)
(EU) 2019/1781

Harmonised standards used

  • EN 60335-1
  • EN 60335-2-41
  • EN 62233: 2008
  • EN 55014-1: 2017 + A11: 2020
  • EN 55014-2: 1997+A1: 2001+A2: 2008
  • EN 61000-3-2: 2014
  • EN 61000-3-3: 2013
  • EN IEC 63000: 2018

Conformity evaluation procedure used
2000/14/EC: Annex V

Sound power level dB(A)
BP 4.500 Garden
Measured: 68
Guaranteed: 71 BP 5.000 Garden
Measured: 70
Guaranteed: 73 BP 6.000 Garden
Measured: 81
Guaranteed: 84 BP 7.000 Garden
Measured: 81
Guaranteed: 83

The signatories act on behalf of and with the authority of the company management.

Documentation supervisor:
S. Reiser Alfred Kärcher SE & Co. KG Alfred-Kärcher-Str. 28 – 40  71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/06/01

Declaration of Conformity (UK)

We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us. This declaration shall cease to be valid if the product is modified without our prior approval.
Product: Pump
Type: 1.645-xxx

Currently applicable UK Regulations
S.I. 2008/1597 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2001/1701 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2010/2617 (as amended)

Commission Regulation(s)
(EU) 2019/1781
Designated standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013

Applied conformity assessment procedure
S.I. 2001/1701 (as amended): Schedule 8 Sound power level dB(A) BP 4.500 Garden
Measured: 68
Guaranteed: 71 BP 5.000 Garden
Measured: 70
Guaranteed: 73 BP 6.000 Garden
Measured: 81
Guaranteed: 84 B  7.000 Garden
Measured: 81
Guaranteed: 83
The signatories act on behalf of and with the authority of the company management.

Documentation supervisor:
S. Reiser Alfred Kärcher SE & Co. KG Alfred-Kärcher-Str. 28 – 40 71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/06/01

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals