EC-LINK Automation Shenzhen Co Ltd EC-RF650 Fixed Reader-Writer Instructions
- October 30, 2023
- EC-LINK Automation Shenzhen Co Ltd
Table of Contents
- EC-LINK Automation Shenzhen Co Ltd EC-RF650 Fixed Reader-Writer
- Product Information
- Product Usage Instructions
- Product Functional Features
- Interface definition
- Human-machine interface requirements
- Drawing
- FCC Caution
- Contact Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EC-LINK Automation Shenzhen Co Ltd EC-RF650 Fixed Reader-Writer
Product Information
The EC-RF650-C-ZM is a five-channel fixed ultra-high frequency RFID reader and writer launched by EC-LINK Automation (Shenzhen) Co. Ltd. It operates at frequencies ranging from 840MHz to 960MHz and meets the ISO 18000-6C standard. The reader has a compact appearance and outstanding read-and-write performance. It supports RS232 and RS485 interface data communication. This reader can be widely used in fields such as automated production line management, retail logistics center management, enterprise transportation management, and warehousing logistics management.
Product Functional Features
- Working frequency band: 840MHz – 960MHz
- Support agreement: ISO 18000-6C/EPC C1G2
- Working mode: frequency hopping
- Output power: maximum 500mW
- Reading and writing distance: greater than 3 meters, related to antenna and label specifications
- Working power supply: DC 7V-30V1A
- Maximum power consumption: 2W
- Operation temperature: -25- +70
- Storage temperature: -40- +85
- Working humidity: 10%~95% RH without condensation
- Communication interface: RS232, RS485
- Finished size: 95X60X14mm
Interface Definition
The EC-RF650-C-ZM has a POWER interface for an external DC9-36V power
adapter and a DB9 female interface for data communication. The DB9 female
interface has the following pin definitions:
Pin | Define | Illustrate |
---|---|---|
1 | NC | hang in the air |
2 | RS_232 TXD | RS_232 send signal |
3 | RS_232 RXD | RS_232 receiving signal |
4 | NC | hang in the air |
5 | GND | digitally |
6 | RS_485 A | RS_485 A |
7 | RS_485 B | RS_485 B |
8 | NC | hang in the air |
ANT Interface
The EC-RF650-C-ZM has an ANT1, ANT2, and ANT3 interface with SMA connectors
for connecting antennas. The RF terminal is only connected to the antenna that
needs to be used. Please do not open the software for unconnected antennas,
otherwise, empty space may damage the reader/writer!
Human Machine Interface Requirements
There is an LED display light on the front of the read-write host:
- Red light on – indicates no data has been uploaded (label not read)
- Green light flashing – indicates data upload (reading label data)
- Blue light flashing – indicates software upgrade in progress
Drawing
Refer to the product manual for a drawing of the EC-RF650-C-ZM reader/writer.
Product Usage Instructions
- Connect an external DC9-36V power adapter to the POWER interface.
- Connect the reader/writer to a computer or other device using the DB9 female interface and an RS232 or RS485 cable.
- Connect an appropriate antenna to one of the ANT interfaces.
- Install the necessary software on the computer or device.
- Place RFID labels within 3 meters of the reader/writer for reading and writing.
- Observe the LED display lights on the front of the reader/writer for status information.
Note:
This device must be professionally installed. This equipment does not allow
any antenna to work with the transmitter; the permitted antenna type must be
specified external antennas, for example (antenna name: Planar RFID antenna,
Model: EC-UHF-ANT-NF0011). This device is generally for industrial/commercial
use. It must be sold to authorized dealers or installers only and cannot be
sold via retail to the general public or by mail order.
EC-RF650 fixed reader/writer
EC-RF650-C-ZM is a five-channel fixed ultra-high frequency RFID reader and
writer launched by EC-LINK company. It meets the ISO 18000-6C standard and
operates at frequencies ranging from 840MHz to 960MHz. It has a compact
appearance and outstanding read-and-write performance, supporting RS232 and
RS485 interface data communication. This reader can be widely used in fields
such as automated production line management, retail logistics center
management, enterprise transportation management, and warehousing logistics
management.
Product Functional Features
- Working frequency band: 840MHz~960MHz
- Support agreement: ISO 18000-6C/EPC C1G2
- Working mode: frequency hopping
- Output power: maximum 500mW
- Reading and writing distance: greater than 3 meters, related to antenna and label specifications.
- Working power supply: DC 7V-30V,1A
- Maximum power consumption: 2W
- Operation temperature: -25℃- +70℃
- Storage temperature: -40℃- +85℃
- Working humidity: 10%~95% RH without condensation
- Communication interface: RS232、RS485
- Finished size: 95X60X14mm
Interface definition
- POWER interface, external DC9-36V power adapter
-
DB9 female interface, connector definition
DB9 Definition of female interfacePin| Define| Illustrate
1| NC| hang in the air
2| RS_232 TXD| RS_232 send signal
3| RS_232 TXD| RS_232 receiving signal
4| NC| hang in the air
5| GND| digitally
6| RS_485 A| RS_485 A
7| RS_485 B| RS_485 B
8| NC| hang in the air - ANT1,ANT2、ANT3Interface, SMA connector, connecting antenna
Note:
The RF terminal is only connected to the antenna that needs to be used. Please
do not open the software for unconnected antennas, otherwise empty space may
damage the reader/writer!
Human-machine interface requirements
There is an LED display light on the front of the read-write host, which is defined as follows:
Pilot lamp | Define |
---|---|
Led | Red light on – indicates no data has been uploaded (label not read) |
Led | Green light flashing – indicates data upload (reading label data) |
Led | Blue light flashing – indicates software upgrade in progress |
Drawing
Caution:
This device must be professionally installed
This equipment does not allow any antenna to work with the transmitter; the
permitted antenna type must be specified external antennas, for example
(antenna name: Planar RFID antenna, Model: EC-UHF-ANT-NF0011) device is
generally for industrial/commercial use. it must be sold to authorized dealers
or installers only, and cannot be sold via retail to the general public or by
mail order. The equipment is an RFID technology RF product and must be
installed by electrical and electronic professionals with a professional
certificate
FCC Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF warning for Mobile devices:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator & your body.
IC Caution
CAN ICES-003(B) / NMB-003(B)
RSS-Gen Issue 3 December 2010″&”CNR-Gen 3e éditionDécembre 2010:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
Contact Information
- ADD: Room2206, Building B, Shixia XintianCentury Business Center, Futian District, Shenzhen
- Website: http://www.eclinksz.com.
- Tel: 0086-755-8368 1813
- Fax: 0086-755-8323 5833
- E-mail: sales@eclink6sz.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>