GE current HORT161 Arize Factor Horticulture LED Lighting System Installation Guide

June 5, 2024
GE current

HORT161 Arize Factor Horticulture LED Lighting System

Installation Guide

HORT161 | 99009070

Arize® Factor
Horticulture LED Lighting System
220-240V versions ONLY. Please see HORT 171 for 380-415V versions

50-60Hz IP65

WARNING

RISK OF ELECTRIC SHOCK

  • Turn power off before inspection, installation  or removal.
  • Properly ground electrical enclosure.

RISK OF FIRE

  • Follow all IEC and local building codes.
  • Use only IEC approved wire for input/output  connections. Minimum size 3G 0.75mm2.

The LED luminaire must be connected to the mains supply according to its ratings on the product label.

CAUTION

  • Do not operate the product with damaged parts.
  • Turn off power before inspection, installation or removal.
  • Luminaire may fall down if not installed properly.
  • Wear work gloves to prevent dirt and oil from being  transferred to the luminaire.
  • Not for direct exposure to the weather.
  • To ensure the product warranty is valid, please  ensure all installation instructions and environmental  conditions for storage and operation are complied with.
  • The light source of this luminaire is not replaceable;  when the light source reaches its end of life the whole  luminaire shall be replaced.
  • Use only in the manner intended by the manufacturer.  If you have any questions, contact the manufacturer.
  • For safe operation, and to maximize the longevity of the luminaire; ensure that the lightbar and driver are clean  and free of dirt, dust, oil, or any other debris.
  • Do not apply any kind of film on the lens or otherwise  cover the driver or light engine in any way.
  • The external flexible cable or cord of this luminaire  cannot be replaced; if the cord is damaged, the  luminaire shall be destroyed.

Arize Factor Installation Guide

Components

lightbar spec

  1. ML Series lightbars (See Lightbar Specifications table on page 2 for details)
  2. GEPSC210-600G-ADGEU Series LED Driver
  3. Suspended Wire Form Support (GEMB-BANE)

1 Lightbar Specifications

Product Code| Detailed Description| Weight| Series Load
per Driver| System Watts
per Lightbar
---|---|---|---|---
GEHF-HPKRW1| ML900, PKR| 2.6 kg| 2| 319W
GEHF-HPKBW1| ML900, PKB| 2.6 kg| 2| 313W
GEHF-HPKFW1| ML900, PKF| 2.6 kg| 2| 313W
GEHF-HBRIW1| ML900, BRI| 2.6 kg| 2| 319W
GEHF-HBRVW1| ML900, BRV| 2.6 kg| 2| 316W
GEHF-MPKRW1| ML900, PKR| 2.6 kg| 4, 5, or 6| 104W
GEHF-MPKBW1| ML900, PKB| 2.6 kg| 4, 5, or 6| 104W
GEHF-MPKFW1| ML900, PKF| 2.6 kg| 4, 5, or 6| 106W
GEHF-MBRIW1| ML900, BRI| 2.6 kg| 4, 5, or 6| 106W
GEHF-MBRVW1| ML900, BRV| 2.6 kg| 4, 5, or 6| 106W
GEHF-EPKBW1| ML900, PKB| 2.6 kg| 5, 6, 7, or 8| 82W

2 LED Driver Specifications

Product Code

|

Detailed Description

|

Weight

| Driver Max Input Ratings
---|---|---|---
Voltage| Current
GEPSC210-600G-ADGEU-D1XA1| Cord /w Leads| 3.33 kg (7.3lbs)| 220-240 VAC| 3.5A

Optional Interconnection Cables Specifications

Product Code|

Detailed Description

---|---
93118693|

900mm Extension Cable

93067609|

1500mm Extension Cable

93067610|

3000mm Extension Cable

Mounting Accessories

mount

Mounting Accessories

SKU Product Code Detailed Description Weight
93153917 GEMB-BAW2 Factor rolling rack mount, 48 inch pitch 3.69 kg (8.1

lbs)
93153918| GEMB-BAW1| Factor rolling rack mount, 24 inch pitch|

1.756 kg (3.86 lbs)

93153914| GEMB-BANE| Factor suspended mount wireform support|

0.012 kg (0.026lbs)

93153916| GEMB-FANE| Factor light engine mount| 3.82 kg (8.4 lbs)
95047411| GEHAK-NN-NE-N0| Driver universal 1’ remote mount kit| 0.2kg (0.4 lbs)
95050824| GEHR-HAR M15| Shorting cap| 0.05kg (0.11lb)

Mounting Distance

mount distant

ML Series Rolling Rack Mount

ML900 Rolling Rack Mount

rockmount

After the horizontal bracket is attached to the strut, secure the bracket to the strut by tightening the two screws located at each end of the bracket.

ML300 Rolling Rack Mount

rollingback

After the horizontal bracket is attached to the strut, secure the bracket to the struts by tightening the two screws, located each end of the bracket.

Rolling Rack Installation Steps

rolling installation

Suspended Mount Installation Steps

mount installation

LED Driver Bracket Mount

brocket

LED Driver Suspended Mount

driver mount

Shorting Cap Installation

RISK OF SAFETY AND PRODUCT DAMAGE. DO NOT MAKE OR BREAK
ELECTRICAL CONNECTION WHILE POWER IS APPLIED.

short cable

ATTENTION: Before attempting to install units or maintenance, ensure power is off.

warning box

ATTENTION: Before attempting to install units or maintenance, ensure power is off.

Wired Dimming Connections (Optional) 0-10v Dimming

factor domain

Save These Instructions

Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

For the latest install guides for your product go to:
https://www.gecurrent.com/indoor-lighting/horticulture-led-grow-lights/arize- ml900
https://www.gecurrent.com/indoor-lighting/horticulture-led-grow-lights/arize- ml300
arize.support@gecurrent.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE current User Manuals

Related Manuals