PHILIPS BPS368 UrbanGlow LED Light Instruction Manual
- October 30, 2023
- Philips
Table of Contents
PHILIPS BPS368 UrbanGlow LED Light
Product Information
- Product Name: UrbanGlow LED gen3
- Model Number: BPS368
- Product Type: Basic
- Power Supply: 220V outdoor, 240V
- Frequency: 50Hz, 60Hz
- IP Rating: IP66
- IK Rating: IK08
- Certification: R&TTE
- LED Color: Red
- Weight: WWWW kg
- LED Manufacturer: ledgine
- Number of LEDs: LED20 16, LED25 16, LED30 16, LED40 16, LED50 40, LED21 20, LED24 20, LED32 20, LED35 20, LED40 20
- Inrush Current: +/-10%
Product Usage Instructions
- Ensure the wall thickness of the pole is between 2.9-3.5mm before installation.
- Install the luminaire and tighten with a torque of 25Nm.
- For maintenance or repair work, disconnect the power supply before proceeding.
- Replace the light source and/or control gear and/or external flexible cable only with the manufacturer or service agent or a similarly qualified person.
- The maximum number of luminaires on MCB 16A type B is determined by the inrush current of +/-10%.
- The recommended distance between luminaires is 3-5 meters.
- The luminaire has basic insulation between low voltage supply and control conductors.
WHAT IN THE BOX
SYMBOLS
LED20 | 16 | 17/E | 15/D | 13/D | 13/C | 16/E | 4,5 | 21A/225µs | 21A/300µs | 26 / 21 |
---|---|---|---|---|---|---|---|---|---|---|
LED25 | 16 | 20/E | 17/D | 15/D | 15/C | 18/E | 4,5 | 21A/225µs | 21A/300µs | 26 / 21 |
LED30 | 16 | 26/E | 22/D | 20/D | 19/C | 24/E | 4,5 | 21A/225µs | 21A/300µs | 26 / 21 |
LED40 | 16 | 36/E | 30/D | 27/D | 25/C | 33/E | 4,5 | 21A/225µs | 21A/300µs | 26 / 21 |
LED50 | 40 | 40/E | 35/D | 31/D | 30/C | 38/E | 4,5 | 47A/250µs | 12A/100µs | 10 / 21 |
LED21| 20| 18/E| 15/D| 14/D| NO| 17/E| 4,5| 21A/225µs| 21A/300µs| 26 /
21
---|---|---|---|---|---|---|---|---|---|---
LED24| 20| 21/E| 17/D| 16/D| 15/C| 19/E| 4,5| 21A/225µs| 21A/300µs| 26 / 21
LED32| 20| 27/E| 23/D| 21/D| 20/C| 25/E| 4,5| 21A/225µs| 21A/300µs| 26 / 21
LED35| 20| 30/E| 26/D| 23/D| 22/C| 28/E| 4,5| 21A/225µs| 21A/300µs| 26 / 21
LED40| 20| 33/E| 29/D| 26/D| 25/C| 31/E| 4,5| 47A/250µs| 12A/100µs| 10 / 21
- Max number of luminaires on MCB 16A type B
- Energy class of the light source
DIMENSIONS
WIRING
INSTALLATION INSTRUCTIONS
SCANNER
- To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).
- To program a spare driver is supported by Signify Service tag (Android only)
Disconnect before servicing
- Luminaire has basic insulation between Low Voltage supply and control conductors.
- The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
- This product contains a light source of energy efficiency class: see table or label.
Zhaga-D4i and SR certified compatibility
For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products / https://www.lighting.philips.co.uk /oem-emea/products/driving-connected-lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.
© 2020 Signify Holding
All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or their respective owners.
Signify Holding
The Netherlands
Printed in Denmark
Data subject to change without notice
Keep for future reference:
www.philips.com/lighting
References
- Sustainable LED lighting solutions | Philips lighting
- Welcome | Philips lighting
- Welcome | Philips lighting
- Driving connected lighting | Philips lighting
- Products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>