Vessel Installation and Operating Manual
Important Safety Information
Please read this manual prior to installation.
Thank you for purchasing Nature
Professional G Inground Vessel provides the housing for the G Inground
Replacement Cartridge which is sold separately. Always refer to the owner’s
manual included with your cartridge for proper start-up procedures and the
required low chlorine recipe. If you have questions, your Nature2. This
Nature2 dealer can provide professional advice and service.
WARNING
Failure to heed the following warnings can result in permanent injury or
drowning.
EQUIPMENT UNDER PRESSURE
- In order to minimize risk of property damage and/or serious injury, including loss of life, always turn pump off prior to installing or changing Nature2 cartridge. Your pump/filter system is operated under pressure and the pressure must be released before you begin work. Please see your pump/filter owner’s manual for further instructions.
PREVENT CHILD DROWNING
- Do not let anyone, especially small children, sit, step, lean or climb on any equipment installed as part of your pool’s operational system. Locate the components of your operational system at least 3 feet from the pool so children cannot use the equipment to access the pool and be injured or drown.
Specifications
Capacity: Up to 45,000 gallons
Dimensions: 20” x 11” x 11.5”
Ports: 2” PVC SKT inlet and outlet or 1.5” FPT
Weight: 10 lbs
Circulation system flow rate: 30-120 GPM
Vessel flow rate: 10-18 GPM (internal by-pass)
Maximum operating pressure: 50 PSI
Replacement cartridge: (sold separately)
G25 10,000 to 25,000 gallons
G35 25,000 to 35,000 gallons
G45 35,000 to 45,000 gallons
Important: The proper replacement cartridge model is indicated on the front
label of your Nature2 vessel.
Limited warranty: Vessel – 5 years
The Nature2 Pool Sanitizer is designed for residential swimming pools only.
IMPORTANT:
Pool owner, save this manual.
Builder, leave this manual with pool owner.
Installation
This vessel has been equipped with an automatic flow-control device, designed
to properly regulate the correct amount of water through the cartridge. Under
normal pump and filter pressure conditions on inground pool systems, the flow
rate to the inlet side of the vessel is 30 to 80 gpm.
If your pump system is designed to produce flow rates greater than 80 gpm, you
should remove the orange flow control diaphragm from the vessel prior to
installation. If your pump system is designed to produce flow rates greater
than 120 gpm or if plumbing is greater than 2”, install the vessel in a bypass
configuration.
Install the Vessel
Refer to the diagram below for part references.
-
Decide where to install the Nature2® vessel. It must be installed:
• On a concrete slab to support the weight of the vessel.
• After the filter on the main return to the pool.
• Before or after the heater (downstream of solar heating systems).
• Before any chemical dispenser or the discharge of any off-line chemical dispenser.
IMPORTANT: Install a check valve before chlorinators to isolate the Nature2® vessel from possible backflow of highly chlorinated water. -
Locate the 2” socket inlet port and outlet port connections on the vessel.
-
Make sure the pump and filter are turned off. Connect the outlet from the filter to the vessel inlet port with the appropriate Schedule 40 PVC pipe*; secure the connection with a pipe glue that is compatible with PVC.
-
Connect the vessel oulet port to the pool return line with the same type of PVC pipe*; secure the connection with the pipe glue.
-
Allow sufficient time for the glue to dry.
-
Screw on the locking ring until it is snug. Do not overtighten.
Check that all connections are secure.
Important: Do not install the Nature2 Cartridge until the vessel installation is complete. -
Start the pump and check for leaks.
Bypass Installation
Install the 2” Nature2 vessel in bypass to the filtration system if plumbing
size is greater than 2” diameter or if flow rates are greater than 120 gpm.
The bypass loop should be after the filter and always before a chemical
dispenser.
If the Nature2 vessel will be installed below the water level of the pool, use
valves to isolate the vessel and prevent the pool from draining during
installation and cartridge changes.
All PVC fittings must be attached to the Nature2 base usings tandard PVC
cement. The vessel should be set on a firm base.
-
Install a tee in the return line to allow water to divert to the Nature2 vessel. Then connect the tee to the vessel inlet.
-
Install a control valve in the return line after the first tee and before the second tee.
-
Fully open any valves (including the control valve) that were closed to isolate the vessel.
-
Start the pump allowing water to pass through the newly plumbed system. The control valve in the return line between the two (2) tees will control the flow through the vessel.
-
With the control valve open, read the pressure on the filter gauge.
-
Adjust the control valve until the filter guage increases by 1.5 psi.
Note: For flows in excess of 120 gpm with the Nature2 vessel in bypass, do not exceed 1.5 psi increase in filter backpressure. Once 1.5 psi is reached, flow is correct through the vessel. -
Check the vessel for leaks. Fix or replace leaking fittings.
*The Nature2 vessel can be reduced to accommodate 1.5” plumbing by using reducing bushings. These bushings will have no effect on the operation of the Nature2 vessel.
Operation and Maintenance
Refer to the Nature2® Cartridge Owner’s Manual for cartridge start-up
procedures.
Filtration and Circulation
Follow the manufacturer’s directions for keeping the circulating pump in good
working order and operate it at least six (6) hours a day. Consult your
Nature2 dealer for optimum run times.
Check the pool filter periodically and clean as recommended by the
manufacturer.
Replacing the Nature2 Cartridge
Use the month indicator ring on the top of the unit to indentify the date on
which the cartridge should be replaced. A Nature2cartridge lasts six (6)
months. To replace the cartridge:
- Shut off your pool’s pump and filter.
- Close any valves between the filter and pool to prevent draining the pool.
- Unscrew the locking ring counterclockwise and remove. Lift cap straight off. You may need to gently rock back and forth to remove.
- Remove the old cartridge.
- Insert the new cartridge.
- Place cap so it rests flat on the housing base. Screw locking ring clockwise until snug: Do not overtighten. Make sure o-ring is secure in the groove on the underside of the cap and not on the vessel.
- Rotate the month indicator ring on the cap top so that the current month is visible in the installation window.
- Open any valves that were closed to isolate the Nature2 vessel.
- Restart your pool’s pump. Check for leaks and fix any leaking fittings.
- Follow the start up procedures included with your Nature2 replacement cartridge.
Installing The Month Indicator Ring
- Insert the ring (with small o-ring in place) into the hole in the center of the cap.
- Apply pressure with the palm of the hand until the ring slips down into place.
- Adjust the month indicator ring to the appropriate month.
Troubleshooting
Use the guide below to correct common pool issues. For further assistance, consult your Nature2 dealer or call us at 1-800-822-7933.
Problem | What to look for: | Treatment |
---|---|---|
The vessel leaks | 1. O-ring missing or improperly seated | |
2. Faulty plumbing | Make sure o-ring is secure in the grove on the underside |
of the cap and not on the vessel.
Repair source of leak in plumbing.
No flow to vessel| Dirty filter (one indication: pressure is 8-10 psi higher
than normal)| Clean or backwash filter so operating pressure is always within
7 psi of a new filter.
Nature2® Professional G Vessel Limited Warranty
The limited warranties contained within this document are the only warranties
given with your Nature2 Professional G Vessel and supercede any prior
warranties. All other warranties, expressed or implied, including the implied
warranty of merchantability or the implied warranty of fitness for a
particular purpose are hereby disclaimed. Our sole obligation under this
warranty, and the purchaser’s sole remedy, is limited to repair or replacement
of the Nature 2 Professional G Vessel, or one of its parts. The Nature 2
warranty applies to the original owner only.
THE LIMITED WARRANTIES OF THE NATURE 2 PROFESSIONAL G VESSEL ARE:
The Nature2 Professional G Vessel you have purchased is warranted to be free
of defects and materials and workmanship for a period of five years from the
date of purchase. Your warranty registration card must be completed and mailed
to Nature2 to establish your installation date.
EXCLUSIONS FROM WARRANTY
Nature2 Professional G Vessel is designed for use on in-ground pools up to
45,000 gallons, dependent on replacement cartridge size. If the unit is used
in any other application, the warranty is void, and the purchaser and/or pool
owner releases the manufacturer from any and all claims related to the use of
the Nature2.
This warranty does not cover problems arising in whole or in part from
purchaser’s negligence, misuse or abuse, improper maintenance or storage,
accident, improper installation, improper application, failure to follow all
appropriate safety precautions, Acts of God, abnormal weather conditions,
damage from plants or animals, and improper use of chemicals.
This warranty specifically excludes all incidental or consequential damages,
except where state law requires them to be paid. This warranty gives you
specific rights. You may have other rights that vary from state to state.
TO SUBMIT A CLAIM
Report claims to Zodiac Pool Systems, Inc. by calling 1-800-822-7933. Only the
original purchaser may submit a claim under this limited warranty. All claims
must be accompanied by an original purchase receipt.
ZODIAC POOL SYSTEMS, INC.
2620 Commerce Way
Vista, CA 92081
Tel: 800-822-7933
Fax: 877-327-1403
www.zodiacpoolsystems.com
©2015 Zodiac Pool Systems, Inc.
All rights reserved. TL-2550 Rev D
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>