Sprint Ray EU Temporary Crown & Teeth Instruction for use

Indication

Sprint Ray EU Temporary Crown & Teeth is a resin for the generative production of long term temporary dental restorations based on image projection systems.

Contraindication

Sprint Ray EU Temporary Crown & Teeth restorations are contraindicated .

  1. … if a patient is known to be allergic to any of the ingredients.
  2.  … for bridges with more than one pontin.
  3.  … for every application that is not part of the indication (see above).

Requirements

Software:
– Ray Ware (CAD)
Hardware:
– Pro Desktop 3D (3D Printing)
– Pro Wash / Dry (Cleaning)
– Pro Cure (Post Curing)
Sprint Ray, Inc., 3577 North Figueroa St., Los Angeles, CA 90065

Material

Sprint Ray EU Temporary Crown & Teeth consists of functional (meth)acrylic resins and inorganic fillers with particle sizes from 0.4 to 3 microns.

Geometric presetting

Connector areas (minimum):
anterior bridges 12 mm²
posterior bridges 14 mm ²
Minimum wall thickness:
occlusal  1.5 mm (central fissure)
circumferential 1 mm

Material parameters

Radiation penetration depth controllable by exposure time
≥ 100 μm (4 mils)
≥ 125 μm (5 mils)

Manufacturing process (fi g. 1-10)

  1. Prepare data (Ray Ware).

  2. Choose process parameters (build style, etc.).

  3. Transfer prepared data to 3D printing device.

  4. Prepare 3D printing – shake bottle.

  5. Fill resin tank of 3D printing device.

  6. Build the parts.

  7. Clean parts (Propwash / Dry):
    – blow surplus resin out of cavities with pressured air before washing
    – wash 5 min. / 5 min.

  8. Dry parts (Propwash / Dry):
    – 3 min.
    – additional: dry with pressured air as required

  9. Post curing (Procure): 5 min. / 60°C.

  10. Finish parts.

Individualization and cementation

The temporary restorations can be individualized by light curing composite materials. The reduction of the restoration should not exceed 0.3 mm (incisal and vestibular area). Please follow the  instructions of the light curing composite manufacturers. For  cementation common provisional dental cements (free of Eugenol) and adhesives are suitable. The inner areas of the crown should be conditioned by sandblasting or other commonly used techniques. Please follow the instructions and indications of the corresponding manufacturers.

Notice

Please follow the instructions provided by the software manufacturer in terms of parameter settings and design recommendations. Please follow the instructions provided by the hardware manufacturer in terms of parameter settings/ printing & post curing recommendations. To avoid detrimental effects on material quality do not expose the liquid material to irradiation under any circumstances. Deviations from the described manufacturing processes or storing conditions may lead to different mechanical and optical properties of the material. Ensure personal protective gear during processing.
Caution: Polymerized resins are chemically resistant – avoid stains on clothing! Avoid any contact with skin and eyes! In case of accidental contact, rinse with adequate running water, consult a doctor if necessary. The lot number and the best before date are indicated on each packaging. In case of claims please always indicate the lot number of the product. Do not use the product after expiry of the best before date. Dispose of contents/container according to official regulations.

Hazard statements

Causes skin irritation. May cause an allergic skin reaction.
Causes serious eye damage. May cause respiratory irritation.
Harmful to aquatic life with long lasting effects.

  • These data come from measurements of a representative sample that was determined as part of our quality assurance.
    ** According to internal design and requirements specifications

SprintRay Temporary Crown and Teeth - fig

Physical properties* Ordering information
Sprint Ray EU Temporary Crown & Teeth Sprint Ray EU Temporary Crown & Teeth

Flexural strength
MP (ISO 4049): > 100| 1 kg: ≤ 405 nm
A1 REF: SRE-1001441
Modulus of elasticity
MP (ISO 4049): > 2000| A2
REF: SRE-1001442
A3
REF: SRE-1001443
A3.5
REF: SRE-1001617
Water absorption
crumple con ISO 10477| B1
REF: SRE-1001618
B2
REF: SRE-1001623 bleach
REF: SRE-1001624
Solubility
conformed a ISO 10477| 500 g: ≤ 405 nm
A1
REF: SRE-1001612
A2
REF: SRE-1001613
A3
REF: SRE-1001614
Inorganic filler
Riempitivo inorganic: 40.0 m-%| A3.5
REF: SRE-1001620
B1
REF: SRE-1001622
B2
REF: SRE-1001625 bleach
REF: SRE-1001626
| This side up.
---|---
| Temperature limit
| CE mark
| Danger
| Do not use if package is damaged.
| Consult instructions for use.
| Keep away from sunlight.
Rx only QTY: 1EA
| Medical Device
| Use by date
| Catalogue number
| Lot number
| Date of manufacture

Manufacturer:
pro3dure medical GmbH
Am Burger 13 · 58642 Iserlohn, Germany
Phone: +49 (0)2374 920050-0 · Fax +49 (0)2374 920050-50
info@pro3dure.com · www.pro3dure.com ·

Made in Germany
Distributor:
Sprint Ray Europe GmbH
Brunnenweg 11 · 64331 Weiterstadt · Germany

Documents / Resources

| SprintRay Temporary Crown and Teeth [pdf] Instructions
Temporary Crown and Teeth, Crown and Teeth, Teeth
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals