STETSOM 120A Infinite Black Power Supply and Charge User Manual
- June 10, 2024
- STETSOM
Table of Contents
120A Infinite Black Power Supply and Charge
User Manual
Models: 70A / 120A 150A / 200A
Introduction
Thank you so much for choosing a STETSOM product! Our new range of power supplies/chargers provides high performance and efficiency thanks to high- quality components and technologies developed for intelligent battery management and charging. Its new design offers high resistance and efficiency, which allows intense and prolonged use without overheating or power losses.
Before installing
Read this manual carefully before using the product.
- All connections must be made with the product OFF.
- Always use cable sizes recommended by the manual. This guarantees maximum security for your installation and the perfect functioning of the product.
- Only use sockets and extension cords compatible with the current consumption of the source. Using poorly installed, poorly sized, or even defective outlets can damage the product or offer risks.
- The source has an automatic boult circuit (127/220Vac).
- Carry out the installation in a firm, ventilated and dry place.
- Never handle the product with wet hands, barefoot or attempt to repair it. Internal components operate at high voltage and pose a risk of electric shock.
- Installation must be done by a qualified professional.
In case of doubt, ask the store where the installation was carried out or contact our Customer Service: +55 18 2104 9412.
Power supply presentation
- AC POWER CONNECTOR: Connect to a compatible outlet for product operation. Do not use adapters or bend the cable, this may reduce the efficiency or cause the cable to malfunction.
- DISPLAY: The LED display allows you to configure programming modes and display real-time current/voltage information.
- DC OUTPUT CONNECTOR (OUTPUT) : Connect to the battery terminals through cables with suitable gauges, following the polarities indicated on the product. Never reverse polarities.
- ON/OFF KEY WITH LED (POWER/PROT) : Allows you to turn the source on or off by pressing the POWER button. The button has an internal LED that will remain lit while the power supply is energized with the switch off (stand-by) or when protection is activated (PROT).
Charging System
The power supplies/chargers provide high-power to power and charge your
battery system with smart features that manage power delivery to optimize
charging and extend battery life. The power supply has the following charging
modes:
FIXED VOLTAGE MODE:
Allows you to select the output voltage from 12.6Vdc to 14.4Vdc to power
amplifiers and other devices. Indicated for use directly on the equipment
without batteries or with batteries and sound playing, offering maximum power
without discharging them.
SMART SLOW CHARGE MODE (SLOW SCS):
The slow charge mode has the exclusive SCS (SMART CHARGE SYSTEM) feature that
intelligently regulates voltages for efficient charging, preventing batteries
from overcharging or heating up, extending their lifespan and preserving their
maximum performance for longer.
Its functioning consists of operating from 5% to 20% of the programmed current
until the voltage reaches 14.4V, remaining in this stage for approximately 8
hours. When charging is complete, the power supply goes into float mode,
supplying 13.8V continuously until another schedule is started or the power
supply is turned off.
SMART FAST CHARGE MODE (FAST SCS):
Fast charge mode has the same SCS (SMART CHARGE SYSTEM) feature but provides
much more current compared to slow charge. It is indicated when the batteries
are discharged and there is little time to charge them. Its functioning
consists of operating from 20% to 35% of the programmed current until the
voltage reaches 14.4V, remaining in this stage for approximately 10 minutes.
When charging is complete, the power supply goes into float mode, supplying
13.8V continuously until another schedule is started or the power supply is
turned off.
OBSERVATIONS
- Always prefer slow charging. It provides less battery wear, preserving their performance and increasing their useful life.
- During the charging process, if the power supply is turned off or the batteries are disconnected, the charging cycle and elapsed time will be restarted.
- The smart charging process is pulsed and is constantly analyzing the voltage and current values of the battery, so it is normal for the fan speed to vary. It is also normal for the displayed voltage to vary rapidly, and may be higher or lower than the configured one.
Operations Modes
The source has operating modes and settings that can be configured from the
display and the MODE/PROG button. Each function has a dedicated LED that
is lit when in use.
MODE / PROGRAMMING BUTTON (MODE/PROG):
Allows switching between operating modes and current/voltage display. Whenever
an operating mode is selected, the LED corresponding to the function will
light up.
QUICK TOUCH: Allows you to switch between display modes and edit
programming parameters: LONG TOUCH : Allows you to enter programming mode
and confirm a parameter:
To switch between display modes and edit parameters, use QUICK TOUCH. To enter programming mode, use the LONG TOUCH. To save changes and exit programming mode, press LONG.
32 MULTIMETER (VOLTAGE AND CURRENT):
Displays DC output voltage and current values through the display and LED
indicators. You can switch between three information display modes with a
single press of the MODE/PROG button:
- Only VOLTAGE 3
- Only CURRENT 2
- Alternate VOLTAGE 3 and CURRENT 2
When a mode is selected, the LED for the function will light up. In alternate
mode, both LEDs will light up (VOLTAGE/CURRENT) for 2s.
The data reported by the multimeter function has an accuracy margin as
indicated:
Voltage tolerance: ±1.5%.
Current tolerance: ±5% from 5% of the nominal value.
FULL CHARGE:
When lit (red LED), it indicates that the batteries are fully charged.
Once full charge is reached, it is not necessary to turn off the source. Its
smart charging system will keep the output voltage at 13.8V, keeping the
batteries always fully charged without causing damage to them.
Setting Modes
FIXED VOLTAGE MODE:
I. Press and hold the button to enter setting mode, the display will start
flashing.
II. Simply tap until the “FIXED VOLTAGE” LED lights up.
III. Keep the button pressed to enter the output voltage setting.
IV. Select the desired voltage value with a single touch, at the end give a
long touch to save and exit the setting mode.
Available voltage options for selection:
VDC • 12.6V • 12.8V • 13.2V • 13.4V • 13.6V • 13.8V • 14.2V • 14.4V
SMART FAST CHARGING MODE (FAST SCS):
I. Hold the button to enter setting mode, the display will start flashing.
II. Simply tap until the “FAST SCS” LED lights up.
III. Hold the button to enter the setting of your battery size or battery
bank.
IV. Select size with a single touch, at the end long press to save and exit
the setting mode.
FONTE 70: 15A ~ 350A
FONTE 120: 25A ~ 600A
A/H
FONTE 150: 36A ~ 750A
FONTE 200: 40A ~ 999A
NOTES:
▪ If your bank size does not match the selection options, use the closest
value.
▪ The number of batteries in the setting may vary depending on the model
purchased.
SMART SLOW CHARGE MODE (SLOW SCS):
I. Press and hold the button to enter setting mode, the display will start
flashing.
II. Simply tap until the “SLOW SCS” LED lights up.
III. Hold the button down to enter setting your battery size or battery bank.
IV. Select size with a single touch, at the end long press to save and exit
the setting mode.
FONTE 70: 15A ~ 350A
FONTE 120: 25A ~ 600A
A/H
FONTE 150: 36A ~ 750A
FONTE 200: 40A ~ 999A
NOTES:
- If your bank size does not fit within the selection options, use the closest value.
- The number of batteries in the setting may vary depending on the model purchased.
The power supply is factory configured to operate in fixed voltage mode (FIXED
VOLTAGE) at 14.4V. Changes in source parameters are saved in the internal
memory
and remain saved even if the source is disconnected from the mains.
Installation
For proper installation, use the gauges recommended in the table:
FONTE 70A
DC output : Use 4 AWG cables.
AC Input: Use a 13 AWG extension up to 10 meters.
FONTE 120A
DC output: Use 2 AWG cables.
AC Input: Use a 11 AWG extension up to 10 meters.
FONTE 150A
DC output: Use 0 AWG cables.
AC Input: Use a 11 AWG extension up to 10 meters.
FONTE 200A
DC output: Use 00 AWG cables.
AC Input: Use a 9 AWG extension up to 10 meters.
Installation should only be carried out by qualified professionals and with
the product OFF.
SIMPLE INSTALLATION
Using a power supply to charge your battery or battery bank and supply power
to your sound equipment:![STETSOM 120A Infinite Black Power Supply and Charge
- SIMPLE](https://manuals.plus/wp-content/uploads/2023/05/STETSOM-120A- Infinite-Black-Power-Supply-and-Charge-SIMPLE.png)
PARALLEL INSTALLATION
Using two or more power supply to power your sound equipment and keep your battery bank charged:
When using more than one power supply in parallel, use only the FIXED VOLTAGE
mode.
All power supplies must be configured for the same output voltage.
Smart charge modes should only be used with a single power supply connected.
INSTALLATION ONLY AS POWER SUPPLY
Using one or more sources to power your sound equipment without using
batteries:
To use the source as a power supply without the help of batteries, make sure
that the total consumption of the powered equipment does not exceed the rated
current supplied by the source. If the peak consumption exceeds this value,
the source will trigger protection.
Protections
When activating a protection, the power supply will turn off and the LED
present on the POWER/PROT button will light up. Check the cause of the problem
and turn the power back on.
The protection features present are:
- Internal AC input fuse : Protection against internal short circuit of the power supply.
- Short circuit at the DC output: Protection against short circuit and overload at the output.
- Low Voltage (Undervoltage): Output voltage protection below 7.5Vdc.
- Temperature: Intelligent monitoring that regulates the operation of the power supply according to the temperature, preventing it from being turned off.
Technical Specifications
FONTE 70A
AC input voltage: | Automatic bi-volt (127Vac/220Vac) |
---|---|
Min. and max. AC voltage: | 127V: 95V ~ 140V / 220V: 165V ~ 240V |
DC output voltage: | 12.6V ~ 14.4V |
Nominal chain: | 70A @ 12.6V |
Maximum power consumption: | 127V: 16.5A / 220V: 8.7A |
Efficiency: | 95% |
Operating modes: | Fixed Voltage, Fast Charge and Slow Charge |
Display features: | Voltage and Current |
AC input protection: | Fuse 15A |
Under Voltage Protection: | 7.5V |
Dimensions (H x W x L): | 3.24″ x 7.0″ x 10.88″ |
Weight: | 5.07 lb. |
FONTE 120A
AC input voltage: | Automatic bi-volt (127Vac/220Vac) |
---|---|
Min. and max. AC voltage: | 127V: 95V ~ 140V / 220V: 165V ~ 240V |
DC output voltage: | 12.6V ~ 14.4V |
Nominal chain: | 120A @ 12.6V |
Maximum power consumption: | 127V: 25.5A / 220V: 16A |
Efficiency: | 90% |
Operating modes: | Fixed Voltage, Fast Charge and Slow Charge |
Display features: | Voltage and Current |
AC input protection: | Fuse 20A |
Under Voltage Protection: | 7.5V |
Dimensions (H x W x L): | 3.24″ x 7.0″ x 13.07″ |
Weight: | 7.05 lb. |
FONTE 150A
AC input voltage: | Automatic bi-volt (127Vac/220Vac) |
---|---|
Min. and max. AC voltage: | 127V: 95V ~ 140V / 220V: 165V ~ 240V |
DC output voltage: | 12.6V ~ 14.4V |
Nominal chain: | 150A @ 12.6V |
Maximum power consumption: | 127V: 30A / 220V: 18.5A |
Efficiency: | 95% |
Operating modes: | Fixed Voltage, Fast Charge and Slow Charge |
Display features: | Voltage and Current |
AC input protection: | Fuse 25A |
Under Voltage Protection: | 7.5V |
Dimensions (H x W x L): | 3.24″ x 7.0″ x 13.07″ |
Weight: | 7.05 lb. |
FONTE 200A
AC input voltage: | Automatic bi-volt (127Vac/220Vac) |
---|---|
Min. and max. AC voltage: | 127V: 95V ~ 140V / 220V: 165V ~ 240V |
DC output voltage: | 12.6V ~ 14.4V |
Nominal chain: | 200A @ 12.6V |
Maximum power consumption: | 127V: 38A / 220V: 24.5A |
Efficiency: | 90% |
Operating modes: | Fixed Voltage, Fast Charge and Slow Charge |
Display features: | Voltage and Current |
AC input protection: | Fuse 30A |
Under Voltage Protection: | 7.5V |
Dimensions (H x W x L): | 3.44″ x 9.5″ x 13.07″ |
Weight: | 9.47 lb. |
Any updates made in this manual will be available for consultation by the
consumer free of charge on the brand’ site. It is recommended that the updated
manual be consulted whenever necessary.
Images contained in this manual are merely illustrative, and may differ
from the real product.
STETSOM INDUSTRIA ELETRÔNICA LTDA. – CNPJ: 61.974.911/0001-04 RUA MARIANO
ARENAALES BENITO, 645 – DISTRITO INDUSTRIAL – CEP 19043-130 PRESIDENTE
PRUDENTE – SP
Warranty Term
STETSOM, through its network of Authorized Technical Assistance Providers,
guarantees technical assistance to the purchaser of their products. The
repairs of any defects duly established as being of the manufacturer will be
done without cost for replacement components or parts and repair labor. The
repairs will be done by the Authorized Technical Assistance Provider
specially designated by STETSOM.
CONSULT THE LIST OF AUTHORIZED TECHNICAL ASSISTANCE PROVIDERS ON OUR WEBSITE: |
---|
[www.stetsom.com.br/en/assistencias-tecnica](http://www.stetsom.com.br/en |
/assistencias-tecnica) |
If you do not locate technical assistance in your city, please contact us at: |
BR +55 18 2104-9412 |
WARRANTY CONDITIONS:
Our warranty is 1 (one) year against manufacturing defects. Its validity
starts on the date of the Sale to the FINAL Consumer.
To make use of the benefits of this warranty, you must present one of the
following documents: the Final Consumer’s SALE NOTE or this completed
CERTIFICATE.
CASES THAT VOID THE WARRANTY:
- 1 year after the issuance of the invoice of sale to the consumer or 1 year of completing certificate of warranty (dated and stamped by the retailer or installer) or 1 year from date of manufacture.
- Violation of seals, alteration or removal of the product’s serial or lot number.
- If the product suffers misuse, careless accidents involving: Water, Fire or Fall, or is installed in conditions contrary to the guidelines contained in the installation manual that accompanies the product.
- Damages and changes in the circuit or adaptation of non-original parts.
- If you use installation techniques contrary to those given in the manual.
QUESTIONS AND ADVICE:
STETSOM offers Customer Services to answer questions and give advice
about their products and services. Please contact us through the channels:
Phone: BR +55 18 2104-9412.
E-mail: suporte@stetsom.com.br
Site: www.stetsom.com
STETSOMBRASIL
GRUPOSTETSOM
STETSOMBRASIL
Serial number:
Date of purchase:
Year of manufacture:
Stamp: www.STETSOM.com.br
R6-B
Documents / Resources
|
STETSOM 120A Infinite Black Power Supply and
Charge
[pdf] User Manual
70A, 120A, 150A, 200A, 120A Infinite Black Power Supply and Charge, 120A,
Infinite Black Power Supply and Charge, Black Power Supply and Charge, Power
Supply and Charge, Charge
---|---
References
- Stetsom - Stetsom
- Stetsom - Stetsom
- Assistências TécnicaTechnical AssistanceAsistencias Técnica - Stetsom
- Assistências TécnicaTechnical AssistanceAsistencias Técnica - Stetsom
- Assistências TécnicaTechnical AssistanceAsistencias Técnica - Stetsom
- Assistências TécnicaTechnical AssistanceAsistencias Técnica - Stetsom
- Assistências TécnicaTechnical AssistanceAsistencias Técnica - Stetsom
- Stetsom - Stetsom
- Assistências TécnicaTechnical AssistanceAsistencias Técnica - Stetsom
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>